The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis

被引:52
作者
Cha, Jae-Kook [1 ]
Paeng, Kyeongwon [1 ]
Jung, Ui-Won [1 ]
Choi, Seong-Ho [1 ]
Sanz, Mariano [2 ,3 ]
Sanz-Martin, Ignacio [2 ]
机构
[1] Yonsei Univ, Dept Periodontol, Coll Dent, Res Inst Periodontal Regenerat, 50-1 Yonsei Ro, Seoul 120752, South Korea
[2] Univ Complutense Madrid, Fac Odontol, Sect Grad Periodontol, Madrid, Spain
[3] Univ Complutense Madrid, ETEP Etiol & Therapy Periodontal Dis Res Grp, Madrid, Spain
关键词
confocal microscope; dental implants; peri-implantitis; scanning electron microscope; surface decontamination; surface macrotopography; titanium; TITANIUM DENTAL IMPLANTS; ULTRASONIC SCALER TIPS; HUMAN GINGIVAL FIBROBLASTS; PERI-IMPLANTITIS; PROLIFERATION; ATTACHMENT; DECONTAMINATION; DEBRIDEMENT; VIABILITY; REMOVAL;
D O I
10.1111/clr.13446
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols. Material and methods Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols: a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces. Results The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect. Conclusion Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
引用
收藏
页码:578 / 587
页数:10
相关论文
共 36 条
[1]  
Albrektsson T, 2004, INT J PROSTHODONT, V17, P536
[2]   Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions [J].
Berglundh, Tord ;
Armitage, Gary ;
Araujo, Mauricio G. ;
Avila-Ortiz, Gustavo ;
Blanco, Juan ;
Camargo, Paulo M. ;
Chen, Stephen ;
Cochran, David ;
Derks, Jan ;
Figuero, Elena ;
Hammerle, Christoph H. F. ;
Heitz-Mayfield, Lisa J. A. ;
Huynh-Ba, Guy ;
Iacono, Vincent ;
Koo, Ki-Tae ;
Lambert, France ;
McCauley, Laurie ;
Quirynen, Marc ;
Renvert, Stefan ;
Salvi, Giovanni E. ;
Schwarz, Frank ;
Tarnow, Dennis ;
Tomasi, Cristiano ;
Wang, Hom-Lay ;
Zitzmann, Nicola .
JOURNAL OF PERIODONTOLOGY, 2018, 89 :S313-S318
[3]   METHOD FOR ULTRASTRUCTURAL STUDIES OF THE INTACT TISSUE-METAL INTERFACE [J].
BJURSTEN, LM ;
EMANUELSSON, L ;
ERICSON, LE ;
THOMSEN, P ;
LAUSMAA, J ;
MATTSSON, L ;
ROLANDER, U ;
KASEMO, B .
BIOMATERIALS, 1990, 11 (08) :596-601
[4]   Influence on proliferation and adhesion of human gingival fibroblasts from different titanium surface decontamination treatments: An in vitro study [J].
Cao, Jie ;
Wang, Tong ;
Pu, Yinfei ;
Tang, Zhihui ;
Meng, Huanxin .
ARCHIVES OF ORAL BIOLOGY, 2018, 87 :204-210
[5]   Surgical Management of Peri-Implantitis: A Systematic Review and Meta-Analysis of Treatment Outcomes [J].
Chan, Hsun-Liang ;
Lin, Guo-Hao ;
Suarez, Fernando ;
MacEachern, Mark ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2014, 85 (08) :1027-1041
[6]   Impact of Implantoplasty on Strength of the Implant-Abutment Complex [J].
Chan, Hsun-Liang ;
Oh, Won-Suck ;
Ong, Hwei Sze ;
Fu, Jia-Hui ;
Steigmann, Marius ;
Sierraalta, Marianella ;
Wang, Hom-Lay .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) :1530-1535
[7]   Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants [J].
Costa-Berenguer, Xavier ;
Garcia-Garcia, Marta ;
Sanchez-Torres, Alba ;
Sanz-Alonso, Mariano ;
Figueiredo, Rui ;
Valmaseda-Castellon, Eduard .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (01) :46-54
[8]   Metal elements in tissue with dental peri-implantitis: a pilot study [J].
Fretwurst, Tobias ;
Buzanich, Guenter ;
Nahles, Susanne ;
Woelber, Johan Peter ;
Riesemeier, Heinrich ;
Nelson, Katja .
CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) :1178-1186
[9]   Influence of titanium surfaces on attachment of osteoblast-like cells in vitro [J].
Jayaraman, M ;
Meyer, U ;
Bühner, M ;
Joos, U ;
Wiesmann, HP .
BIOMATERIALS, 2004, 25 (04) :625-631
[10]   Rotating titanium brush for plaque removal from rough titanium surfaces - an in vitro study [J].
John, Gordon ;
Becker, Juergen ;
Schwarz, Frank .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) :838-842