Battery Storage Integration in Voltage Unbalance and Overvoltage Mitigation Control Strategies and Its Impact on the Power Quality

被引:22
作者
Bozalakov, Dimitar [1 ]
Mnati, Mohannad J. [1 ]
Laveyne, Joannes [1 ]
Desmet, Jan [2 ]
Vandevelde, Lieven [1 ,3 ]
机构
[1] Univ Ghent, Dept Elect Energy Met Mech Construct & Syst EEMMe, Elect Energy Lab EELAB, Technol Pk Zwijnaarde 131, B-9052 Ghent, Belgium
[2] Univ Ghent, Dept Elect Energy Met Mech Construct & Syst EEMMe, Elect Energy Lab EELAB LEMCKO, Campus Kortrijk,Graaf Karel Goedelaan 34, B-8500 Kortrijk, Belgium
[3] Flanders Make, B-3920 Lommel, Belgium
关键词
energy storage; storage capacity; overvoltages; voltage unbalance; ancillary services; DISTRIBUTION-SYSTEM; DISTRIBUTION GRIDS; HIGH PENETRATION; GENERATION; MANAGEMENT; INVERTERS; NETWORKS;
D O I
10.3390/en12081501
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increased utilisation of distributed renewable energy sources in low voltage grids leads to power quality problems such as overvoltages and voltage unbalance. This imposes challenges to the distribution system operators to maintain the power quality in their grids. To overcome these issues, energy storage systems could be integrated together with the distributed energy resources and the stored energy could be used when needed to better improve power quality and achieve better grid performance. However, integrating an energy storage system introduces additional cost, therefore, determining the right capacity is essential. In this article, an energy storage system is combined with the classical positive-sequence control strategy and the three-phase damping control strategy. The three-phase damping control strategy is able to mitigate the voltage unbalance by emulating a resistive behaviour towards the zero- and negative-sequence voltage components. This resistive behaviour can be set on different values such that the desired voltage unbalance mitigation is achieved. Hence, the three-phase damping control strategy, equipped with the energy storage system is investigated under different values of the resistive behaviour. Both control strategies are investigated under the same conditions and the impact of the different capacities of the energy storage systems is investigated.
引用
收藏
页数:26
相关论文
共 47 条
[1]  
[Anonymous], P 37 IEEE POW EL SPE
[2]  
[Anonymous], P 2016 IEEE PES INN
[3]  
[Anonymous], P 2017 INT C EN SUST
[4]  
[Anonymous], INCREASING PENETRATI
[5]  
[Anonymous], 2012, P 2012 IEEE POW EN S
[6]  
[Anonymous], THESIS
[7]  
[Anonymous], 501602008 EN CENCENE
[8]  
[Anonymous], P INT S POW EL EL DR
[9]  
[Anonymous], THESIS
[10]   Impact of Switching Harmonics on Capacitor Cells Balancing in Phase-Shifted PWM-Based Cascaded H-Bridge STATCOM [J].
Behrouzian, Ehsan ;
Bongiorno, Massimo ;
Teodorescu, Remus .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) :815-824