Comparison of coagulation activity tests in vitro for selected biomaterials

被引:31
作者
van Oeveren, W
Haan, J
Lagerman, P
Schoen, T
机构
[1] Univ Groningen, Dept Biomed Engn, NL-9700 AB Groningen, Netherlands
[2] HaemoProbe BV, Groningen, Netherlands
关键词
coagulation tests; blood compatibility;
D O I
10.1046/j.1525-1594.2002.06872.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Testing of coagulation induced by external communicating medical devices is an International Standardisation Organization (ISO) requirement for products exposed to human blood. Four categories of tests are indicated by ISO 10993/4: a clotting test (partial thromboplastin time; PTT), thrombin generation, fibrinogen deposition, or measurement of coagulation split products. We evaluated the specificity of these tests on various polymers and found only thrombin generation and fibrinogen binding sensitive and reproducible tests while thrombin generation correlated best with the classical PTT. The thrombin generation assay is therefore the method of choice for testing coagulation induced by biomaterials and medical devices.
引用
收藏
页码:506 / 511
页数:6
相关论文
共 15 条
[1]   STUDIES ON A NEW STRATEGY FOR SURFACE MODIFICATION OF POLYMERIC BIOMATERIALS [J].
ALDENHOFF, YBJ ;
KOOLE, LH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (08) :917-928
[2]  
BRASH JL, 1988, BLOOD, V71, P932
[3]  
Dawids S., 1993, Test Procedures for the Blood Compatibility of Biomaterials
[4]  
Eriksson C, 1997, J BIOMED MATER RES, V37, P130, DOI 10.1002/(SICI)1097-4636(199710)37:1<130::AID-JBM16>3.0.CO
[5]  
2-K
[6]   A new in vitro model to study interaction between whole blood and biomaterials. Studies of platelet and coagulation activation acid the effect of aspirin [J].
Hong, J ;
Ekdahl, KN ;
Reynolds, H ;
Larsson, R ;
Nilsson, B .
BIOMATERIALS, 1999, 20 (07) :603-611
[7]   Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition [J].
Huang, N ;
Yang, P ;
Cheng, X ;
Leong, YX ;
Zheng, XL ;
Cai, GJ ;
Zhen, ZH ;
Zhang, F ;
Chen, YR ;
Liu, XH ;
Xi, TF .
BIOMATERIALS, 1998, 19 (7-9) :771-776
[8]   SURFACE MODIFICATIONS OF A GLASS AND A GLASS-CERAMIC OF THE MGO-3CAO-CENTER-DOT-P2O5-SIO2 SYSTEM IN A SIMULATED BODY-FLUID [J].
OLIVEIRA, JM ;
CORREIA, RN ;
FERNANDES, MH .
BIOMATERIALS, 1995, 16 (11) :849-854
[9]   LOCAL INTRAVASCULAR EFFECTS OF THE NITINOL WIRE BLOOD-CLOT FILTER [J].
PRINCE, MR ;
SALZMAN, EW ;
SCHOEN, FJ ;
PALESTRANT, AM ;
SIMON, M .
INVESTIGATIVE RADIOLOGY, 1988, 23 (04) :294-300
[10]   PLASMA RECALCIFICATION AS A MEASURE OF CONTACT PHASE ACTIVATION AND HEPARINIZATION EFFICACY AFTER CONTACT WITH BIOMATERIALS [J].
RHODES, NP ;
WILLIAMS, DF .
BIOMATERIALS, 1994, 15 (01) :35-37