Study on the utilization of heat in the mechanically ventilated Trombe wall in a house with a central air conditioning and air circulation system

被引:40
作者
Ma, Qingsong [1 ]
Fukuda, Hiroatsu [1 ,2 ]
Lee, Myonghyang [3 ]
Kobatake, Takumi [4 ]
Kuma, Yuko [5 ]
Ozaki, Akihito [6 ]
机构
[1] Univ Kitakyushu, Dept Architecture, Kitakyushu, Fukuoka 8080135, Japan
[2] Chengdu Univ, Sch Architecture & Civil Engn, Chengdu 610106, Sichuan, Peoples R China
[3] Ritsumeikan Univ, Dept Architecture & Urban Design, Kyoto 6038577, Japan
[4] Tohata Architects & Engineers, Osaka 5410043, Japan
[5] Shonan Inst Technol, Fac Engn, Fujisawa, Kanagawa 2510046, Japan
[6] Kyushu Univ, Dept Architecture & Urban Design, Fukuoka 8120053, Japan
基金
日本学术振兴会;
关键词
Air circulation system; Mechanically ventilated Trombe wall; Heating load reduction; Numerical simulation; PERFORMANCE ANALYSIS; ENERGY PERFORMANCE;
D O I
10.1016/j.apenergy.2018.04.010
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a study on a mechanically ventilated Trombe wall that adds additional windows to the storage wall. The mechanically ventilated Trombe wall is located on the south side of the house with a central air conditioning and air circulation system. To reduce the heating load, during the heating period, the heat from the Trombe wall air channel is sent to the air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Taking a house located in Miyazaki, Japan as an example, we conducted an actual survey to understand the situation of heat utilization of the Trombe wall and used numerical simulations to examine the effective method of heat utilization of the Trombe wall. Results showed that in all-day air conditioning, even when sending the air in the Trombe wall to the air-conditioned room, the temperature of the Trombe wall remained high. The heating load was reduced by sending the air from the Trombe wall to the central air-conditioned room and installing the large heat capacity material on the floor in the Trombe wall.
引用
收藏
页码:861 / 871
页数:11
相关论文
共 29 条
[11]   Numerical study of a composite Trombe solar wall integrating microencapsulated PCM [J].
Leang, Enghok ;
Tittelein, Pierre ;
Zalewski, Laurent ;
Lassue, Stephane .
CISBAT 2017 INTERNATIONAL CONFERENCE FUTURE BUILDINGS & DISTRICTS - ENERGY EFFICIENCY FROM NANO TO URBAN SCALE, 2017, 122 :1009-1014
[12]   A numerical and experimental analysis of the air vent management and heat storage characteristics of a trombe wall [J].
Liu, Yanfeng ;
Wang, Dengjia ;
Ma, Chao ;
Liu, Jiaping .
SOLAR ENERGY, 2013, 91 :1-10
[13]   Study of a Double-Layer Trombe Wall Assisted by a Temperature-Controlled DC Fan for Heating Seasons [J].
Ma, Qingsong ;
Fukuda, Hiroatsu ;
Kobatake, Takumi ;
Lee, Myonghyang .
SUSTAINABILITY, 2017, 9 (12)
[14]  
Melero S, 2011, Architecture & sustainable development, V2, P267
[15]  
Mohamed L., 2015, P 2015 6 INT REN EN, DOI [10.1109/IREC.2015.7110881, DOI 10.1109/IREC.2015.7110881]
[16]   Trombe wall redesign for a poultry chick brooding application in the equatorial region - analysis of the thermal performance of the system using the Galerkin finite elements [J].
Nwosu, Nwachukwu Paul .
INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2010, 29 (01) :37-47
[17]  
Ozaki A., 2006, J INT BUILDING PERFO, V16, P30
[18]  
Ozaki A., 2004, P ESIM 2004 CAN C BU, P45
[19]   Experimental study of the heating performance of a Trombe wall with a new design [J].
Rabani, Mehran ;
Kalantar, Vali ;
Dehghan, Ali A. ;
Faghih, Ahmadreza K. .
SOLAR ENERGY, 2015, 118 :359-374
[20]   Numerical simulation of a Trombe wall to predict the energy storage rate and time duration of room heating during the non-sunny periods [J].
Rabani, Mehran ;
Kalantar, Vali ;
Faghih, Ahmadreza K. ;
Rabani, Mehrdad ;
Rabani, Ramin .
HEAT AND MASS TRANSFER, 2013, 49 (10) :1395-1404