Study on the utilization of heat in the mechanically ventilated Trombe wall in a house with a central air conditioning and air circulation system

被引:40
作者
Ma, Qingsong [1 ]
Fukuda, Hiroatsu [1 ,2 ]
Lee, Myonghyang [3 ]
Kobatake, Takumi [4 ]
Kuma, Yuko [5 ]
Ozaki, Akihito [6 ]
机构
[1] Univ Kitakyushu, Dept Architecture, Kitakyushu, Fukuoka 8080135, Japan
[2] Chengdu Univ, Sch Architecture & Civil Engn, Chengdu 610106, Sichuan, Peoples R China
[3] Ritsumeikan Univ, Dept Architecture & Urban Design, Kyoto 6038577, Japan
[4] Tohata Architects & Engineers, Osaka 5410043, Japan
[5] Shonan Inst Technol, Fac Engn, Fujisawa, Kanagawa 2510046, Japan
[6] Kyushu Univ, Dept Architecture & Urban Design, Fukuoka 8120053, Japan
基金
日本学术振兴会;
关键词
Air circulation system; Mechanically ventilated Trombe wall; Heating load reduction; Numerical simulation; PERFORMANCE ANALYSIS; ENERGY PERFORMANCE;
D O I
10.1016/j.apenergy.2018.04.010
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a study on a mechanically ventilated Trombe wall that adds additional windows to the storage wall. The mechanically ventilated Trombe wall is located on the south side of the house with a central air conditioning and air circulation system. To reduce the heating load, during the heating period, the heat from the Trombe wall air channel is sent to the air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Taking a house located in Miyazaki, Japan as an example, we conducted an actual survey to understand the situation of heat utilization of the Trombe wall and used numerical simulations to examine the effective method of heat utilization of the Trombe wall. Results showed that in all-day air conditioning, even when sending the air in the Trombe wall to the air-conditioned room, the temperature of the Trombe wall remained high. The heating load was reduced by sending the air from the Trombe wall to the central air-conditioned room and installing the large heat capacity material on the floor in the Trombe wall.
引用
收藏
页码:861 / 871
页数:11
相关论文
共 29 条
[1]  
Adams S, 2010, P SOL EN SOC ANN C
[2]   An innovative Trombe wall as a passive heating system for a building in Athens-A comparison with the conventional Trombe wall and the insulated wall [J].
Bellos, Evangelos ;
Tzivanidis, Christos ;
Zisopoulou, Eleni ;
Mitsopoulos, Georgios ;
Antonopoulos, Kimon A. .
ENERGY AND BUILDINGS, 2016, 133 :754-769
[3]   Optimizing energy and environmental performance of passive Trombe wall [J].
Bojic, Milorad ;
Johannes, Kevyn ;
Kuznik, Frederic .
ENERGY AND BUILDINGS, 2014, 70 :279-286
[4]   Energy performance of Trombe walls: Adaptation of ISO 13790:2008(E) to the Portuguese reality [J].
Briga-Sa, Ana ;
Martins, Analisa ;
Boaventura-Cunha, Jose ;
Lanzinha, Joao Carlos ;
Paiva, Anabela .
ENERGY AND BUILDINGS, 2014, 74 :111-119
[5]   Air flow and thermal efficiency characteristics in solar chimneys and Trombe Walls [J].
Burek, S. A. M. ;
Habeb, A. .
ENERGY AND BUILDINGS, 2007, 39 (02) :128-135
[6]  
CRECER, WHAT IS COMF TEMP HU
[7]   Energy and exergy analysis of different Trombe walls [J].
Duan, Shuangping ;
Jing, Chengjun ;
Zhao, Zhiqiang .
ENERGY AND BUILDINGS, 2016, 126 :517-523
[8]   Comparative study on the annual performance of three types of building integrated photovoltaic (BIPV) Trombe wall system [J].
Hu, Zhongting ;
He, Wei ;
Ji, Jie ;
Hu, Dengyun ;
Lv, Song ;
Chen, Hongbing ;
Shen, Zhihe .
APPLIED ENERGY, 2017, 194 :81-93
[9]   A review on the application of Trombe wall system in buildings [J].
Hu, Zhongting ;
He, Wei ;
Ji, Jie ;
Zhang, Shengyao .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 70 :976-987
[10]   An improved approach for the application of Trombe wall system to building construction with selective thermo-insulation fa‡ades [J].
Ji Jie ;
Luo ChengLong ;
Sun Wei ;
Yu HanCheng ;
He Wei ;
Pei Gang .
CHINESE SCIENCE BULLETIN, 2009, 54 (11) :1949-1956