Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements

被引:90
作者
Kohnen, Thomas [1 ]
Thomala, Martin Christian [1 ]
Cichocki, Magdalena [1 ]
Strenger, Anja [1 ]
机构
[1] Univ Frankfurt, Dept Ophthalmol, D-60590 Frankfurt, Germany
关键词
D O I
10.1016/j.jcrs.2006.08.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare internal horizontal anterior chamber (AC) diameter determined by optical coherence tomography (OCT) and horizontal corneal diameter (white-to-white [WTW]) using automated measurements. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: Internal AC diameter and WTW distance was measured in 52 eyes of 26 patients using the Visante OCT (Carl Zeiss Meditec), IOLMaster (Carl Zeiss Meditec), and Orbscan Ilz topography system (Bausch & Lomb). Statistical evaluation was performed using the Bland-Altman method and regression analysis for comparison of measurement techniques. The Kruskal-Wallis test was used to measure the repeatability of each device. RESULTS: The mean internal AC diameter was 12.45 mm +/- 0.53 (SD) with OCT; the mean WTW distance was 12.17 +/- 0.45 mm with the IOLMaster and 11.84 +/- 0.41 mm with the Orbscan IIz. A positive regression was determined for AC diameter and both WTW measurements. Measurement values varied little between both WTW measurement systems (R-2 = 0.9384). CONCLUSIONS: Anterior chamber measurement using optical coherence tomography (Visante OCT) was easy to handle and showed good repeatability. The internal horizontal diameter of the AC was larger than the horizontal corneal diameter determined by automated WTW measurements (IOLMaster, Orbscan Ilz). Optical coherence tomography with the Visante OCT allows direct measurement of the AC width.
引用
收藏
页码:1809 / 1813
页数:5
相关论文
共 10 条
[1]   Static and dynamic analysis of the anterior segment with optical coherence tomography [J].
Baikoff, G ;
Lutun, E ;
Ferraz, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :1843-1850
[2]   Comparison of manual and automated methods to determine horizontal corneal diameter [J].
Baumeister, M ;
Terzi, E ;
Ekici, Y ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :374-380
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
Bron AJ, 1997, WOLFFS ANATOMY EYE O, P279
[5]   Magnetic resonance imaging and Orbscan assessment of the anterior chamber [J].
Fea, AM ;
Annetta, F ;
Cirillo, S ;
Campanella, D ;
De Giuseppe, M ;
Regge, D ;
Grignolo, FM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1713-1718
[6]   Anterior chamber width measurement by high speed optical coherence tomography [J].
Goldsmith, JA ;
Li, Y ;
Chalita, MR ;
Westphal, V ;
Patil, CA ;
Rollins, AM ;
Izatt, JA ;
Huang, D .
OPHTHALMOLOGY, 2005, 112 (02) :238-244
[7]   Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation [J].
Kohnen, T ;
Kasper, T ;
Terzi, E .
OPHTHALMOLOGE, 2005, 102 (11) :1105-1117
[8]   Intraocular lenses for the correction of refraction errors. Part 1: Phakic anterior chamber lenses [J].
Kohnen, T ;
Baumeister, M ;
Cichocki, M .
OPHTHALMOLOGE, 2005, 102 (10) :1003-1017
[9]   Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles [J].
Radhakrishnan, S ;
Goldsmith, J ;
Huang, D ;
Westphal, V ;
Dueker, DK ;
Rollins, AM ;
Izatt, JA ;
Smith, SD .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) :1053-1059
[10]   Correlation between different measurements within the eye relative to phakic intraocular lens implantation [J].
Werner, L ;
Izak, AM ;
Pandey, SK ;
Apple, DJ ;
Trivedi, RH ;
Schmidbauer, JM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :1982-1988