Calculation of HPGe efficiency for environmental samples: comparison of EFFTRAN and GEANT4

被引:38
作者
Nikolic, Jelena [1 ]
Vidmar, Tim [2 ]
Jokovic, Dejan [3 ]
Rajacic, Milica [1 ]
Todorovic, Dragana [1 ]
机构
[1] Univ Belgrade, Inst Nucl Sci Vinca, Belgrade 11001, Serbia
[2] CEN SCK, Belgian Nucl Res Ctr, B-2400 Mol, Belgium
[3] Univ Belgrade, Inst Phys, Belgrade, Serbia
关键词
HPGe; Calibration; EFFTRAN; GEANT4; DETECTOR; SPECTROMETER;
D O I
10.1016/j.nima.2014.06.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Determination of full energy peak efficiency is one of the most important tasks that have to be performed before gamma spectrometry of environmental samples. Many methods, including measurement of specific reference materials, Monte Carlo simulations, efficiency transfer and semi empirical calculations, were developed in order to complete this task. Monte Carlo simulation, based on GEANT4 simulation package and EFFTRAN efficiency transfer software are applied for the efficiency calibration of three detectors, readily used in the Environment and Radiation Protection Laboratory of Institute for Nuclear Sciences Vinca, for measurement of environmental samples. Efficiencies were calculated for water, soil and aerosol samples. The aim of this paper is to perform efficiency calculations for HPGe detectors using both GEANT4 simulation and EFFTRAN efficiency transfer software and to compare obtained results with the experimental results. This comparison should show how the two methods agree with experimentally obtained efficiencies of our measurement system and in which part of the spectrum do the discrepancies appear. The detailed knowledge of accuracy and precision of both methods should enable us to choose an appropriate method for each situation that is presented in our and other laboratories on a daily basis. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 13 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
[Anonymous], WORKSH DOE NUCL DAT
[3]  
[Anonymous], APPL RAD ISOTOPES
[4]  
Gilmore G., 2008, PRACTICALGAMMARAYSPE
[5]   Precise efficiency calibration of an HPGe detector: source measurements and Monte Carlo calculations with sub-percent precision [J].
Hardy, JC ;
Iacob, VE ;
Sanchez-Vega, M ;
Effinger, RT ;
Lipnik, P ;
Mayes, VE ;
Willis, DK ;
Helmer, RG .
APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) :65-69
[6]   Monte Carlo simulations of the response of a plastic scintillator and an HPGe spectrometer in coincidence [J].
Jokovic, D. R. ;
Dragic, A. ;
Udovicic, V. ;
Banjanac, R. ;
Puzovic, J. ;
Anicin, I. .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (05) :719-722
[7]   A method to estimate a contribution of Ge(n,n′) reaction to the low-energy part of gamma spectra of HPGe detectors [J].
Krmar, M. ;
Hansman, J. ;
Jovancevic, N. ;
Lalovic, N. ;
Slivka, J. ;
Jokovic, D. ;
Maletic, D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 709 :8-11
[8]   An empirical expression for the full energy peak efficiency of an N-type high purity germanium detector [J].
Osae, EK ;
Nyarko, BJB ;
Serfor-Armah, Y ;
Darko, EO .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (03) :617-622
[9]   User-friendly Monte Carlo program for the generation of gamma-ray spectral responses in complex source-detector arrangements [J].
Puzovic, JM ;
Anicin, IV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 414 (2-3) :279-282
[10]   Influence of the geometrical characteristics of an HpGe detector on its efficiency [J].
Vargas, MJ ;
Timón, AF ;
Díaz, NC ;
Sánchez, DP .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 253 (03) :439-443