In vitro and in vivo evaluation of a new large animal spirometry device using mainstream CO2 flow sensors

被引:10
作者
Ambrisko, T. D. [1 ]
Lammer, V. [1 ]
Schramel, J. P. [1 ]
Moens, Y. P. S. [1 ]
机构
[1] Univ Vet Med, Dept Compan Anim & Horses, Vienna, Austria
关键词
horse; capnography; mechanical ventilation; monitoring; respiratory; spirometry; AGREEMENT; VOLUME;
D O I
10.1111/evj.12140
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Reasons for performing study A spirometry device equipped with mainstream CO2 flow sensor is not available for large animal anaesthesia. Objectives To measure the resistance of a new large animal spirometry device and assess its agreement with reference methods for volume measurements. Study design In vitro experiment and crossover study using anaesthetised horses. Methods A flow partitioning device (FPD) equipped with 4 human CO2 flow sensors was tested. Pressure differences were measured across the whole FPD and across each sensor separately using air flows (range: 90-720l/min). One sensor was connected to a spirometry monitor for in vitro volume (3, 5 and 7l) measurements. These measurements were compared with a reference method. Five anaesthetised horses were used for tidal volume (VT) measurements using the FPD and a horse-lite sensor (reference method). Bland-Altman analysis, ANOVA and linear regression analysis were used for data analysis. Results Pressure differences across each sensor were similar suggesting equal flow partitioning. The resistance of the device increased with flow (range: 0.3-1.5 cmH2O s/l) and was higher than that of the horse-lite. The limits of agreement for volume measurements were within -1 and 2% in vitro and -12 and 0% in vivo. Nine of 147 VT measurements in horses were outside of the +/- 10% limits of acceptance but most of these erroneous measurements occurred with VTs lower than 4l. The determined correction factor for volume measurements was 3.97 +/- 0.03. Conclusions The limits of agreement for volume measurements by the new device were within +/- 10% using clinically relevant range of volumes. The new spirometry device can be recommended for measurement of VT in adult Warmblood horses.
引用
收藏
页码:507 / 511
页数:5
相关论文
共 10 条
[1]   Continuous versus intermittent thermodilution for cardiac output measurement during alveolar recruitment manoeuvres in sheep [J].
Ambrisko, Tamas D. ;
Coppens, Paul ;
Moens, Yves .
VETERINARY ANAESTHESIA AND ANALGESIA, 2011, 38 (05) :423-430
[2]  
Blanch L, 2006, MINERVA ANESTESIOL, V72, P577
[3]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[4]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Dorsch J., 1999, UNDERSTANDING ANESTH, V4th
[7]   In vitro validation of a Pitot-based flow meter for the measurement of respiratory volume and flow in large animal anaesthesia [J].
Moens, Yves P. S. ;
Gootjes, Peter ;
Ionita, Jean-Claude ;
Heinonen, Erkki ;
Schatzmann, Urs .
VETERINARY ANAESTHESIA AND ANALGESIA, 2009, 36 (03) :209-219
[8]   VENTILATION-PERFUSION RELATIONSHIPS IN THE ANESTHETIZED HORSE [J].
NYMAN, G ;
HEDENSTIERNA, G .
EQUINE VETERINARY JOURNAL, 1989, 21 (04) :274-281
[9]   Measurement of tidal volume using Respiratory Ultrasonic Plethysmography in anaesthetized, mechanically ventilated horses [J].
Russold, Elena ;
Ambrisko, Tamas D. ;
Schramel, Johannes P. ;
Auer, Ulrike ;
Van Den Hoven, Rene ;
Moens, Yves P. .
VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (01) :48-54
[10]  
Schramel J. P., 2013, VET ANAESTH IN PRESS