Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT

被引:26
作者
Davenport, Matthew S. [1 ,2 ,3 ]
Parikh, Kushal R. [1 ,3 ]
Mayo-Smith, William W. [4 ]
Israel, Gag M. [5 ]
Brown, Richard K. J. [1 ,3 ]
Ellis, James H. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, 1500 E Med Ctr Dr B2-A209P, Ann Arbor, MI 48108 USA
[2] Univ Michigan Hlth Syst, Dept Urol, Ann Arbor, MI USA
[3] Michigan Radiol Qual Collaborat, Ann Arbor, MI USA
[4] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[5] Yale Univ, Sch Med, Dept Radiol, New Haven, CT 06510 USA
关键词
Quality assurance; contrast material; weight-based; cost; CT; LEAN BODY-WEIGHT; HEPATIC ENHANCEMENT; SURFACE AREA; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; BLOOD-VOLUME; MASS INDEX; CHILDREN; FORMULA; ABDOMEN;
D O I
10.1016/j.jacr.2016.09.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the magnitude of subject-level and population-level cost savings that could be realized by moving from fixed volume low-osmolality iodinated contrast material administration to an effective weight-based dosing regimen for contrast-enhanced abdominopelvic CT. Methods: HIPAA-compliant, institutional review board exempt retrospective cohort study of 6,737 subjects undergoing contrast enhanced abdominopelvic CT from 2014 to 2015. Subject height, weight, lean body weight (LBW), and body surface area (BSA) were determined. Twenty-six volume- and weight-based dosing strategies with literature support were compared with a fixed-volume strategy used at the study institution: 125 mL 300 mgI/mL for routine CT, 125 mL 370 mgI/mL for multiphasic CT (single energy, 120 kVp). The predicted population- and subject-level effects on cost and contrast material utilization were calculated for each strategy and sensitivity analyses were performed. Results: Most subjects underwent routine CT (91% [6,127/6,737]). Converting to lesser-volume higher-concentration contrast material had the greatest effect on cost; a fixed-volume 100 mL 370 mgI/mL strategy resulted in $132,577 in population-level savings with preserved iodine dose at routine CT (37,500 versus 37,000 mgI). All weight-based iodine-content dosing strategies (mgI/kg) with the same maximum contrast material volume (125 mL) were predicted to contribute mean savings compared with the existing fixed-volume algorithm ($4,053-$116,076/strategy in the overall study population, $1-$17/strategy per patient). Similar trends were observed in all sensitivity analyses. Conclusions: Large cost and material savings can be realized at abdominopelvic CT by adopting a weight-based dosing strategy and lowering the maximum volume of administered contrast material. (C) 2016 American College of Radiology
引用
收藏
页码:359 / 370
页数:12
相关论文
共 33 条
  • [21] Body Size Indexes for Optimizing Iodine Dose for Aortic and Hepatic Enhancement at Multidetector CT: Comparison of Total Body Weight, Lean Body Weight, and Blood Volume
    Kondo, Hiroshi
    Kanematsu, Masayuki
    Goshima, Satoshi
    Tomita, Yuhei
    Kim, Myeong-Jin
    Moriyama, Noriyuki
    Onozuka, Minoru
    Shiratori, Yoshimune
    Bae, Kyongtae T.
    [J]. RADIOLOGY, 2010, 254 (01) : 163 - 169
  • [22] Abdominal Multidetector CT in Patients with Varying Body Fat Percentages: Estimation of Optimal Contrast Material Dose
    Kondo, Hiroshi
    Kanematsu, Masayuki
    Goshima, Satoshi
    Tomita, Yuhei
    Miyoshi, Toshiharu
    Hatcho, Atsushi
    Moriyama, Noriyuki
    Onozuka, Minoru
    Shiratori, Yoshimune
    Bae, Kyongtae T.
    [J]. RADIOLOGY, 2008, 249 (03) : 872 - 877
  • [23] DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT
    KORMANO, M
    PARTANEN, K
    SOIMAKALLIO, S
    KIVIMAKI, T
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : 364 - 367
  • [24] The Recent Downturn in Utilization of CT: The Start of a New Trend?
    Levin, David C.
    Rao, Vijay M.
    Parker, Laurence
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2012, 9 (11) : 795 - 798
  • [25] SIMPLIFIED CALCULATION OF BODY-SURFACE AREA
    MOSTELLER, RD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (17) : 1098 - 1098
  • [26] James Lean Body Weight Formula Is Not Appropriate for Determining CT Contrast Media Dose in Patients with High Body Mass Index
    Nyman, Ulf
    [J]. RADIOLOGY, 2016, 278 (03) : 956 - 957
  • [27] Evaluating Contrast Agent Waste and Costs of Weight-Based CT Contrast Bolus Protocols Using Single-or Multiple-Dose Packaging
    Robinson, Jeffrey D.
    Mitsumori, Lee M.
    Linnau, Ken F.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (06) : W617 - W620
  • [28] Contrast and Cost Savings by Implementation of a Multidose Bulk IV Contrast Delivery System
    Routhier, Justin
    Piazzo, Kathy
    Sodickson, Aaron
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2011, 8 (04) : 265 - 270
  • [29] Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures
    Svensson, Anders
    Nouhad, Jallo
    Cederlund, Kerstin
    Aspelin, Peter
    Nyman, Ulf
    Bjork, Jonas
    Torkel, Brismar B.
    [J]. ACTA RADIOLOGICA, 2012, 53 (06) : 601 - 606
  • [30] Patterns of intravenous contrast material use and corticosteroid premedication in children-a survey of Society of Chairs of Radiology in Children's Hospitals (SCORCH) member institutions
    Trout, Andrew T.
    Dillman, Jonathan R.
    Ellis, James H.
    Cohan, Richard H.
    Strouse, Peter J.
    [J]. PEDIATRIC RADIOLOGY, 2011, 41 (10) : 1272 - 1283