Extraction of the cardiac waveform from simultaneous multislice fMRI data using slice sorted averaging and a deep learning reconstruction filter

被引:23
作者
Asian, Serdar [1 ,2 ]
Hocke, Lia [1 ,2 ]
Schwarz, Nicolette [1 ,2 ]
Frederick, Blaise [1 ,2 ]
机构
[1] McLean Hosp, Brain Imaging Ctr, 115 Mill St, Belmont, MA 02478 USA
[2] Harvard Univ, Sch Med, Dept Psychiat, Boston, MA 02115 USA
关键词
BOLD; fMRI; Cardiac waveform; Plethysmogram; Physiological noise; HEART-RATE-VARIABILITY; PHYSIOLOGICAL NOISE; BOLD; FLUCTUATIONS; RESPIRATION; SIGNALS;
D O I
10.1016/j.neuroimage.2019.05.049
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Cardiac signal contamination has long confounded the analysis of blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). Cardiac pulsation results in significant BOLD signal changes, especially in and around blood vessels. Until the advent of simultaneous multislice echo-planar imaging (EPI) acquisition, the time resolution of whole brain EPI was insufficient to avoid cardiac aliasing (and acquisitions with repetition times (TRs) under 400-500 ms are still uncommon). As a result, direct detection and removal of the cardiac signal with spectral filters is generally not possible. Modelling methods have been developed to mitigate cardiac contamination, and recently developed techniques permit the visualization of cardiac signal propagation through the brain in undersampled data (e.g., TRs > 1s), which is useful in its own right for finding blood vessels. However, both of these techniques require data from which to estimate cardiac phase, which is generally not available for the data in many large databases of existing imaging data, and even now is not routinely recorded in many fMRI experiments. Here we present a method to estimate the cardiac waveform directly from a multislice fMRI dataset, without additional physiological measurements, such as plethysmograms. The pervasive spatial extent and temporal structure of the cardiac contamination signal across the brain offers an opportunity to exploit the nature of multislice imaging to extract this signal from the fMRI data itself. While any particular slice is recorded at the TR of the imaging experiment, slices are recorded much more quickly - typically from 10 to 20 Hz - sufficiently fast to fully sample the cardiac signal. Using the fairly permissive assumptions that the cardiac signal is a) pseudoperiodic b) somewhat coherent within any given slice, and c) is similarly shaped throughout the brain, we can extract a good estimate of the cardiac phase as a function of time from fMRI data alone. If we make further assumptions about the shape and consistency of cardiac waveforms, we can develop a deep learning filter to greatly improve our estimate of the cardiac waveform.
引用
收藏
页码:303 / 316
页数:14
相关论文
共 36 条
[11]  
Chollet F., 2015, Keras
[12]   AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages [J].
Cox, RW .
COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (03) :162-173
[13]   Image Super-Resolution Using Deep Convolutional Networks [J].
Dong, Chao ;
Loy, Chen Change ;
He, Kaiming ;
Tang, Xiaoou .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2016, 38 (02) :295-307
[14]   On the Analysis of Fingertip Photoplethysmogram Signals [J].
Elgendi, Mohamed .
CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) :14-25
[15]   Correcting for Blood Arrival Time in Global Mean Regression Enhances Functional Connectivity Analysis of Resting State fMRI-BOLD Signals [J].
Erdogan, Sinem B. ;
Tong, Yunjie ;
Hocke, Lia M. ;
Lindsey, Kimberly P. ;
Frederick, Blaise deB .
FRONTIERS IN HUMAN NEUROSCIENCE, 2016, 10
[16]   Scalable Object Detection using Deep Neural Networks [J].
Erhan, Dumitru ;
Szegedy, Christian ;
Toshev, Alexander ;
Anguelov, Dragomir .
2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, :2155-2162
[17]  
Frederick B., 2016, RAPIDTIDE SUITE PYTH
[18]  
Girshick R., 2014, IEEE COMP SOC C COMP, DOI [10.1109/CVPR.2014.81, DOI 10.1109/CVPR.2014.81]
[19]   The minimal preprocessing pipelines for the Human Connectome Project [J].
Glasser, Matthew F. ;
Sotiropoulos, Stamatios N. ;
Wilson, J. Anthony ;
Coalson, Timothy S. ;
Fischl, Bruce ;
Andersson, Jesper L. ;
Xu, Junqian ;
Jbabdi, Saad ;
Webster, Matthew ;
Polimeni, Jonathan R. ;
Van Essen, David C. ;
Jenkinson, Mark .
NEUROIMAGE, 2013, 80 :105-124
[20]  
Glover GH, 2000, MAGNET RESON MED, V44, P162, DOI 10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO