Development of a method for the analysis of drugs of abuse in vitreous humor by capillary electrophoresis with diode array detection (CE-DAD)

被引:29
作者
Costa, Jose Luiz [1 ,5 ]
Morrone, Andre Ribeiro [2 ]
Resende, Rodrigo Ribeiro [3 ]
da Matta Chasin, Alice Aparecida [4 ]
Maggi Tavares, Marina Franco [5 ]
机构
[1] Criminalist Inst Sao Paulo, Forens Toxicol & Chem Lab, Sao Paulo, Brazil
[2] Sao Paulo State Police, Inst Legal Med, Sao Paulo, Brazil
[3] Univ Fed Minas Gerais, Inst Biol Sci, Dept Biochem & Immunol, Belo Horizonte, MG, Brazil
[4] Univ Sao Paulo, Fac Pharmaceut Sci, Sao Paulo, Brazil
[5] Univ Sao Paulo, Inst Chem, Sao Paulo, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 945卷
关键词
Capillary zone electrophoresis; Vitreous humor; Forensic toxicology; Cocaine; Liquid chromatography-mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SYSTEMATIC TOXICOLOGICAL ANALYSIS; FLIGHT MASS-SPECTROMETRY; ZONE-ELECTROPHORESIS; FORENSIC TOXICOLOGY; SAMPLE STACKING; HPLC-DAD; BLOOD; POTASSIUM; COCAINE;
D O I
10.1016/j.jchromb.2013.10.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work presents the development of an analytical method based on capillary electrophoresis with diode array detection for the analysis of drugs of abuse and biotransformation products in vitreous humor. Composition of the background electrolyte, implementation of an online pre-concentration strategy and sample preparation procedures were objects of study. The complete electrophoretic separation of 12 analytes (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDEA), ketamine, cocaine, cocaethylene, lidocaine, morphine, 6-monoacetylmorphine and heroin) and the internal standard N-methyl-1-(3,4-methylenedioxyphenyl)-2-butamine (MBDB) was obtained within 13 min of run. The method was validated presenting good linearity (r(2) > 0.99), recovery >= 90%, precision better than 12% RSD and acceptable accuracy in the range of 86-118% at three concentration levels (50, 100 and 500 ng/mL). LODs and LOQs in the order of 1-5 ng/mL and 5-10 ng/mL, respectively, were obtained. After validation, the method was applied to eighty-seven vitreous humor samples and the results were compared to those obtained by a liquid chromatography tandem mass spectrometry (LC-MS/MS) screening method, routinely used by the forensic toxicology laboratory of the Sao Paulo State Police, Brazil. Cocaine was detected in 7.1%, cocaethylene in 3.6%, lidocaine in 2.4% and ketamine in 1.2% of the total number of analyzed samples. (C) 2013 Published by Elsevier B.V.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 48 条
[1]  
[Anonymous], 2009, Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens
[2]   Chemical analysis of ecstasy pills [J].
Baggott, M ;
Heifets, B ;
Jones, RT ;
Mendelson, J ;
Sferios, E ;
Zehnder, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 284 (17) :2190-2190
[3]  
Beckers JL, 2000, ELECTROPHORESIS, V21, P2747, DOI 10.1002/1522-2683(20000801)21:14<2747::AID-ELPS2747>3.0.CO
[4]  
2-Z
[5]   STANDARDIZED HPLC/DAD SYSTEM, BASED ON RETENTION INDEXES AND SPECTRAL LIBRARY, APPLICABLE FOR SYSTEMATIC TOXICOLOGICAL SCREENING [J].
BOGUSZ, M ;
WU, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :188-197
[6]   Study of vitreous potassium correlation with time since death in the postmortem range from 2 to 110 hours using capillary ion analysis [J].
Bortolotti, Federica ;
Pascali, Jennifer P. ;
Davis, Gregory G. ;
Smith, Frederick P. ;
Brissie, Robert M. ;
Tagliaro, Franco .
MEDICINE SCIENCE AND THE LAW, 2011, 51 :S20-S23
[7]  
Coe J I, 1974, J Forensic Sci, V19, P13
[8]   Distribution of phencyclidine into vitreous humor [J].
Cox, Dawn ;
Phipps, Rebecca A. Jufer ;
Levinel, Barry ;
Jacobs, Aaron ;
Fowler, David .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (08) :537-539
[9]   Development of a capillary zone electrophoresis method including a factorial design and simplex optimisation for analysis of amphetamine, amphetamine analogues, cocaine, and heroin [J].
Dahlén, J ;
von Eckardstein, S .
FORENSIC SCIENCE INTERNATIONAL, 2006, 157 (2-3) :93-105
[10]   A CLASS-INDEPENDENT DRUG SCREEN IN FORENSIC TOXICOLOGY USING A PHOTODIODE-ARRAY DETECTOR [J].
DRUMMER, OH ;
KOTSOS, A ;
MCINTYRE, IM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (04) :225-229