Vickers hardness investigation of work-hardening in used NiTi rotary instruments

被引:18
作者
Alapati, Satish B.
Brantley, William A.
Nusstein, John M.
Daehn, Glenn S.
Svec, Timothy A.
Powers, John M.
Johnston, William M.
Guo, Wenhua
机构
[1] Ohio State Univ, Coll Dent, Sect Restorat & Prosthet Dent, Columbus, OH 43218 USA
[2] Ohio State Univ, Coll Dent, Sect Oral Biol, Columbus, OH 43218 USA
[3] Ohio State Univ, Coll Dent, Sect Endodont, Columbus, OH 43218 USA
[4] Ohio State Univ, Coll Engn, Dept Mat Sci & Engn, Columbus, OH 43218 USA
[5] Univ Texas, Dent Branch, Dept Endodont, Houston, TX USA
[6] Univ Texas, Dent Branch, Dept Restorat Dent & Biomat, Houston, TX USA
[7] Rice Univ, Ctr Environm & Biol Nanotechnol, Houston, TX 77251 USA
关键词
D O I
10.1016/j.joen.2006.07.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A contributing mechanism for clinical failure of NiTi rotary instruments might be excessive work hardening. Vickers hardness was measured with 300 gm load near the flutes in three regions (D2-D4, D6-D10, and D14 towards the shank) for nine representative clinically used ProFile GT instruments that had been axially sectioned (10 measurements in each region). Consistent values could not be obtained at D1. Minimum hardness occurred at D2 to D4, with means from 313 to 324 (SD from 7 to 16). Maximum hardness with means ranging widely from 330 to 481 was found beyond D14. Mean hardness at D2 to D4 was 320 for an as-received ProFile instrument. Because a mean Vickers hardness of 326 has been reported for a shape-memory NiTi orthodontic wire product, it can be concluded that the NiTi instruments did not experience substantial work hardening at D2 to D4 during clinical use, in agreement with previous differential scanning calorimetric analyses.
引用
收藏
页码:1191 / 1193
页数:3
相关论文
共 22 条
[1]   SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Nusstein, JM ;
Daehn, GS .
JOURNAL OF ENDODONTICS, 2005, 31 (01) :40-43
[2]   Proposed role of embedded dentin chips for the clinical failure of nickel-titanium rotary instruments [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Nusstein, JM ;
Daehn, GS .
JOURNAL OF ENDODONTICS, 2004, 30 (05) :339-341
[3]   K3 endo, ProTaper, and ProFile systems: Breakage and distortion, in severely curved roots of molars [J].
Ankrum, MT ;
Hartwell, GR ;
Truitt, JE .
JOURNAL OF ENDODONTICS, 2004, 30 (04) :234-237
[4]  
Bergmans L, 2001, AM J DENT, V14, P324
[5]  
Brantley W.A., 2001, Thieme., P77
[6]   Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use [J].
Brantley, WA ;
Svec, TA ;
Iijima, M ;
Powers, JM ;
Grentzer, TH .
JOURNAL OF ENDODONTICS, 2002, 28 (11) :774-778
[7]  
Brockhurst P, 1998, Aust Endod J, V24, P115
[8]  
DIETER CE, 1986, MECH METALLURGY, P329
[9]   Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors [J].
Gambarini, G .
JOURNAL OF ENDODONTICS, 2001, 27 (12) :772-774
[10]  
Gambarini G, 2000, ENDOD DENT TRAUMATOL, V16, P95