Deep Learning Automated Detection of Reticular Pseudodrusen from Fundus Autofluorescence Images or Color Fundus Photographs in AREDS2

被引:22
|
作者
Keenan, Tiarnan D. L. [1 ]
Chen, Qingyu [2 ]
Peng, Yifan [2 ]
Domalpally, Amitha [3 ]
Agron, Elvira [1 ]
Hwang, Christopher K. [1 ]
Thavikulwat, Alisa T. [1 ]
Lee, Debora H. [1 ]
Li, Daniel [2 ]
Wong, Wai T. [1 ,4 ]
Lu, Zhiyong [2 ]
Chew, Emily Y. [1 ]
机构
[1] NEI, Div Epidemiol & Clin Applicat, NIH, Bethesda, MD 20892 USA
[2] Natl Lib Med, Natl Ctr Biotechnol Informat, NIH, Bethesda, MD 20894 USA
[3] Univ Wisconsin, Fundus Photograph Reading Ctr, Madison, WI USA
[4] NEI, Sect Neuron Glia Interact Retinal Dis, Lab Retinal Cell & Mol Biol, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
MACULAR DEGENERATION; SEVERITY SCALE; EYE DISEASE; ATROPHY; CLASSIFICATION; TRIAL;
D O I
10.1016/j.ophtha.2020.05.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop deep learning models for detecting reticular pseudodrusen (RPD) using fundus auto-fluorescence (FAF) images or, alternatively, color fundus photographs (CFP) in the context of age-related macular degeneration (AMD). Design: Application of deep learning models to the Age-Related Eye Disease Study 2 (AREDS2) dataset. Participants: FAF and CFP images (n = 11 535) from 2450 AREDS2 participants. Gold standard labels from reading center grading of the FAF images were transferred to the corresponding CFP images. Methods: A deep learning model was trained to detect RPD in eyes with intermediate to late AMD using FAF images (FAF model). Using label transfer from FAF to CFP images, a deep learning model was trained to detect RPD from CFP (CFP model). Performance was compared with 4 ophthalmologists using a random subset from the full test set. Main Outcome Measures: Area under the receiver operating characteristic curve (AUC), kappa value, accuracy, and F1 score. Results: The FAF model had an AUC of 0.939 (95% confidence interval [CI], 0.927-0.950), a k value of 0.718 (95% CI, 0.685-0.751), and accuracy of 0.899 (95% CI, 0.887-0.911). The CFP model showed equivalent values of 0.832 (95% CI, 0.812-0.851), 0.470 (95% CI, 0.426-0.511), and 0.809 (95% CI, 0.793-0.825), respectively. The FAF model demonstrated superior performance to 4 ophthalmologists, showing a higher k value of 0.789 (95% CI, 0.675-0.875) versus a range of 0.367 to 0.756 and higher accuracy of 0.937 (95% CI, 0.907-0.963) versus a range of 0.696 to 0.933. The CFP model demonstrated substantially superior performance to 4 ophthalmologists, showing a higher k value of 0.471 (95% CI, 0.330-0.606) versus a range of 0.105 to 0.180 and higher accuracy of 0.844 (95% CI, 0.798-0.886) versus a range of 0.717 to 0.814. Conclusions: Deep learning-enabled automated detection of RPD presence from FAF images achieved a high level of accuracy, equal or superior to that of ophthalmologists. Automated RPD detection using CFP achieved a lower accuracy that still surpassed that of ophthalmologists. Deep learning models can assist, and even augment, the detection of this clinically important AMD-associated lesion. Published by Elsevier on behalf of the American Academy of Ophthalmology
引用
收藏
页码:1674 / 1687
页数:14
相关论文
共 50 条
  • [1] Deep learning automated detection of reticular pseudodrusen from fundus autofluorescence images and color fundus photographs in the Age-Related Eye Disease Study 2 (AREDS2)
    Keenan, Tiarnan D. L.
    Chen, Qingyu
    Peng, Yifan
    Domalpally, Amitha
    Agron, Elvira
    Hwang, Christopher K.
    Thavikulwat, Alisa Therese
    Lee, Debora Hana
    Li, Daniel
    Wong, Wai T.
    Lu, Zhiyong
    Chew, Emily
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [2] A deep learning model for generating fundus autofluorescence images from color fundus photography
    Song, Fan
    Zhang, Weiyi
    Zheng, Yingfeng
    Shi, Danli
    He, Mingguang
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (04): : 192 - 198
  • [3] Detection of Reticular Pseudodrusen on Embossed Color Fundus Photos
    Kadomoto, Shin
    Nittala, Muneeswar Gupta
    Karamat, Ayesha Nuri
    Nanegrungsunk, Onnisa
    Sadda, Srinivas R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [4] A Deep Learning Approach for Automated Detection of Geographic Atrophy from Color Fundus Photographs
    Keenan, Tiarnan D.
    Dharssi, Shazia
    Peng, Yifan
    Chen, Qingyu
    Agron, Elvira
    Wong, Wai T.
    Lu, Zhiyong
    Chew, Emily Y.
    OPHTHALMOLOGY, 2019, 126 (11) : 1533 - 1540
  • [5] COMPARISON OF COLOR FUNDUS PHOTOGRAPHS AND FUNDUS AUTOFLUORESCENCE IMAGES IN MEASURING GEOGRAPHIC ATROPHY AREA
    Khanifar, Aziz A.
    Lederer, David E.
    Ghodasra, Jason H.
    Stinnett, Sandra S.
    Lee, Jane J.
    Cousins, Scott W.
    Bearelly, Srilaxmi
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (09): : 1884 - 1891
  • [6] Enhanced Detection of Reticular Pseudodrusen on Color Fundus Photos by Image Embossing
    Kadomoto, Shin
    Nanegrungsunk, Onisa
    Nittala, Muneeswar Gupta
    Karamat, Ayesha
    Sadda, SriniVas R.
    CURRENT EYE RESEARCH, 2022, 47 (11) : 1547 - 1552
  • [7] Deep Learning for Automated Assessment of Retinal Degeneration in Fundus Autofluorescence Images
    Lo, Pei-An
    Pollalis, Dimitrios
    Chen, Yuning
    Chan, Anson
    Nguyen, Andrew
    Chong, Peter
    Humayun, Mark S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [8] Deep learning-based automated detection of glaucomatous optic neuropathy on color fundus photographs
    Li, Feng
    Yan, Lei
    Wang, Yuguang
    Shi, Jianxun
    Chen, Hua
    Zhang, Xuedian
    Jiang, Minshan
    Wu, Zhizheng
    Zhou, Kaiqian
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (04) : 851 - 867
  • [9] Deep learning-based automated detection of glaucomatous optic neuropathy on color fundus photographs
    Feng Li
    Lei Yan
    Yuguang Wang
    Jianxun Shi
    Hua Chen
    Xuedian Zhang
    Minshan Jiang
    Zhizheng Wu
    Kaiqian Zhou
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 851 - 867
  • [10] Fundus Autofluorescence Imaging and Macular Atrophy in Eyes with Neovascular Age Related Macular Degeneration in AREDS2
    Domalpally, Amitha
    Danis, Ronald P.
    Chew, Emily Y.
    Clemons, Traci E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)