Polymerization Shrinkage Evaluation of Restorative Resin-Based Composites Using Fiber Bragg Grating Sensors

被引:16
作者
Lins, Rodrigo [1 ]
Vinagre, Alexandra [2 ]
Alberto, Nelia [3 ]
Domingues, Maria F. [3 ]
Messias, Ana [2 ]
Martins, Luis R. [1 ]
Nogueira, Rogerio [3 ]
Ramos, Joao C. [2 ,4 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Ave Limeira 901, BR-13414903 Piracicaba, SP, Brazil
[2] Univ Coimbra, Inst Operat Dent, Dent Area, Fac Med, Ave Bissaya Barreto,Blocos Celas, P-3700075 Coimbra, Portugal
[3] Campus Univ Santiago, Inst Telecomunicacoes, P-3810193 Aveiro, Portugal
[4] Inst Portugues Med Dent, Rua Jose Luciano Castro 141, P-3800207 Aveiro, Portugal
关键词
resin based-composites; bulk-fill composite resins; light curing; polymerization shrinkage; optical fiber sensors; fiber Bragg gratings; BULK-FILL RESIN; PHYSICAL-PROPERTIES; STRESS; LIGHT; MODULUS;
D O I
10.3390/polym11050859
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The purpose of this study was to compare the linear polymerization shrinkage of different restorative resin-based composites (RBCs) using fiber Bragg grating (FBG) sensors. Five RBCs were evaluated: Zirconfill((R)) (ZFL); Aura Bulk-Fill (ABF); Tetric((R)) N-Ceram Bulk-Fill (TBF); Filtek(TM) Bulk-Fill (FBF); and Admira Fusion-Ormocer((R)) (ADF). Ten samples per resin were produced in standardized custom-made half-gutter silicone molds. Two optical FBG sensors were used to assess temperature and polymerization shrinkage. Light curing was performed for 40 s and polymerization shrinkage was evaluated at 5, 10, 40, 60, 150, and 300 s. Statistical analysis was accomplished for normal distribution (Shapiro-Wilk, p > 0.05). Two-way repeated measures ANOVA with Greenhouse-Geisser correction followed by Bonferroni ' s post-hoc test was used to analyze the linear shrinkage data (p < 0.05). ZFL showed the highest linear shrinkage and ADF the lowest. Shrinkage increased for all RBCs until 300 s, where significant differences were found between ADF and all other resins (p < 0.05). Among bulk-fill RBCs, TBF showed the lowest shrinkage value, but not statistically different from FBF. The ADF presented lower linear shrinkage than all other RBCs, and restorative bulk-fill composites exhibited an intermediate behavior.
引用
收藏
页数:12
相关论文
共 36 条
[1]   Characterization of different water/powder ratios of dental gypsum using fiber Bragg grating sensors [J].
Alberto, Nelia ;
Carvalho, Lidia ;
Lima, Hugo ;
Antunes, Paulo ;
Nogueira, Rogerio ;
Pinto, Joao L. .
DENTAL MATERIALS JOURNAL, 2011, 30 (05) :700-706
[2]   Evaluation of polymerization shrinkage and hydroscopic expansion of fiber-reinforced biocomposites using optical fiber Bragg grating sensors [J].
Anttila, Emilia J. ;
Krintila, Outi H. ;
Laurila, Toni K. ;
Lassila, Lippo V. J. ;
Vallittu, Pekka K. ;
Hernberg, Rolf G. R. .
DENTAL MATERIALS, 2008, 24 (12) :1720-1727
[3]   Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review [J].
Braga, RR ;
Ballester, RY ;
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (10) :962-970
[4]  
Carletti T., 2017, P 24 DENT M PIR 9 IN
[5]   Polymerization stress, shrinkage and elastic modulus of current low-shrinkage restorative composites [J].
Cidreira Boaro, Leticia Cristina ;
Goncalves, Flavia ;
Guimaraes, Thayse Costa ;
Ferracane, Jack Liborio ;
Versluis, Antheunis ;
Braga, Roberto Ruggiero .
DENTAL MATERIALS, 2010, 26 (12) :1144-1150
[6]   Recent Advances and Developments in Composite Dental Restorative Materials [J].
Cramer, N. B. ;
Stansbury, J. W. ;
Bowman, C. N. .
JOURNAL OF DENTAL RESEARCH, 2011, 90 (04) :402-416
[7]   Polymerization Shrinkage Stress Kinetics and Related Properties of Bulk-fill Resin Composites [J].
El-Damanhoury, H. M. ;
Platt, J. A. .
OPERATIVE DENTISTRY, 2014, 39 (04) :374-382
[8]   Polymerization stress - Is it clinically meaningful? [J].
Ferracane, Jack L. ;
Hilton, Thomas J. .
DENTAL MATERIALS, 2016, 32 (01) :1-10
[9]   Contraction stress related to composite inorganic content [J].
Goncalves, F. ;
Kawano, Y. ;
Braga, R. R. .
DENTAL MATERIALS, 2010, 26 (07) :704-709
[10]   BisGMA/TEGDMA ratio and filler content effects on shrinkage stress [J].
Goncalves, Flavia ;
Azevedo, Caio L. N. ;
Ferracane, Jack L. ;
Braga, Roberto R. .
DENTAL MATERIALS, 2011, 27 (06) :520-526