Sensitive detection of Porcine circovirus-2 by droplet digital polymerase chain reaction

被引:33
作者
Zhao, Shan [1 ]
Lin, Hua [3 ]
Chen, Shijie [3 ]
Yang, Miao [3 ]
Yan, Qigui [1 ,2 ]
Wen, Caifang [1 ]
Hao, Zhongxiang [1 ]
Yan, Yubao [3 ]
Sun, Yingjie [3 ]
Hu, Juan [3 ]
Chen, Zhenrong [1 ]
Xi, Lixin [1 ]
机构
[1] Sichuan Agr Univ, Coll Vet Med, Chengdu 611130, Peoples R China
[2] Sichuan Agr Univ, Key Lab Anim Dis & Human Hlth Sichuan Prov, Chengdu 611130, Peoples R China
[3] Sichuan Entry Exit Inspect & Quarantine Bur, Chengdu, Peoples R China
关键词
Detection; droplet digital PCR; Porcine circovirus-2; TaqMan real-time PCR; REAL-TIME PCR; PORCINE CIRCOVIRUS TYPE-2; DNA COPY NUMBER; QUANTITATIVE DETECTION; QUANTIFICATION; SAMPLES; ASSAY; PIGS;
D O I
10.1177/1040638715608358
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Sensitive detection of Porcine circovirus-2 (PCV-2) is very important for surveillance of postweaning multisystemic wasting syndrome. Droplet digital polymerase chain reaction (ddPCR) is novel PCR method that can achieve high precision. Our study aimed to develop a sensitive assay utilizing ddPCR to detect PCV-2. Specificity of the assay was confirmed by the failure of amplification of DNA of other relevant viruses. The detection limit for ddPCR was 25 copies/L, a 4-fold greater sensitivity than TaqMan real-time PCR. Both methods showed a high degree of linearity (R-2 = similar to 1), although TaqMan real-time PCR showed less sensitivity than ddPCR for clinical detection. Our findings indicate that ddPCR might represent a promising platform for detecting PCV-2 viral loads.
引用
收藏
页码:784 / 788
页数:5
相关论文
共 16 条
  • [1] Quantitation of porcine circovirus type 2 isolated from serum/plasma and tissue samples of healthy pigs and pigs with postweaning multisystemic wasting syndrome using a TaqMan-based real-time PCR
    Brunborg, IM
    Moldal, T
    Jonassen, CM
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2004, 122 (02) : 171 - 178
  • [2] Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus
    Hayden, R. T.
    Gu, Z.
    Ingersoll, J.
    Abdul-Ali, D.
    Shi, L.
    Pounds, S.
    Caliendo, A. M.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (02) : 540 - 546
  • [3] Droplet Digital™ PCR quantitation of HER2 expression in FFPE breast cancer samples
    Heredia, Nicholas J.
    Belgrader, Phillip
    Wang, Shenglong
    Koehler, Ryan
    Regan, Jack
    Cosman, Angela M.
    Saxonov, Serge
    Hindson, Benjamin
    Tanner, Stephanie C.
    Brown, Alexandra S.
    Karlin-Neumann, George
    [J]. METHODS, 2013, 59 (01) : S20 - S23
  • [4] Absolute quantification by droplet digital PCR versus analog real-time PCR
    Hindson, Christopher M.
    Chevillet, John R.
    Briggs, Hilary A.
    Gallichotte, Emily N.
    Ruf, Ingrid K.
    Hindson, Benjamin J.
    Vessella, Robert L.
    Tewari, Muneesh
    [J]. NATURE METHODS, 2013, 10 (10) : 1003 - +
  • [5] Molecular quantification of environmental DNA using microfluidics and digital PCR
    Hoshino, Tatsuhiko
    Inagaki, Fumio
    [J]. SYSTEMATIC AND APPLIED MICROBIOLOGY, 2012, 35 (06) : 390 - 395
  • [6] Comparison of droplet digital PCR and quantitative real-time PCR for examining population dynamics of bacteria in soil
    Kim, Tae Gwan
    Jeong, So-Yeon
    Cho, Kyung-Suk
    [J]. APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2014, 98 (13) : 6105 - 6113
  • [7] Use of artificial DNA with multiple probe sites as reference DNA templates for quantitative real-time PCR to examine methanogen communities
    Kim, Tae Gwan
    Yi, Taewoo
    Cho, Kyung-Suk
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2013, 48 (04): : 417 - 421
  • [8] Droplet digital PCR as a useful tool for the quantitative detection of Enterovirus 71
    Lui, Yan Long Edmund
    Tan, Eng Lee
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2014, 207 : 200 - 203
  • [9] High Sensitivity Detection and Quantitation of DNA Copy Number and Single Nucleotide Variants with Single Color Droplet Digital PCR
    Miotke, Laura
    Lau, Billy T.
    Rumma, Rowza T.
    Ji, Hanlee P.
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (05) : 2618 - 2624
  • [10] High-throughput and sensitive next-generation droplet digital PCR assay for the quantitation of the hepatitis C virus mutation at core amino acid 70
    Mukaide, Motokazu
    Sugiyama, Masaya
    Korenaga, Masaaki
    Murata, Kazumoto
    Kanto, Tatsuya
    Masaki, Naohiko
    Mizokami, Masashi
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2014, 207 : 169 - 177