Tricuspid insufficiency does not increase early after permanent implantation of pacemaker leads

被引:47
作者
Kucukarslan, N
Kirilmaz, A
Ulusoy, E
Yokusoglu, M
Gramatnikovski, N
Ozal, E
Tatar, H
机构
[1] GATA Mil Med Hosp, Dept Cardiovasc Surg, Ankara, Turkey
[2] GATA Haydarpasa Mil Hosp, Cardiol Sect, TR-34668 Istanbul, Turkey
[3] GATA Mil Med Hosp, Dept Cardiol, TR-34668 Istanbul, Turkey
关键词
D O I
10.1111/j.1540-8191.2006.00251.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Interference between pacemaker (PM) lead and tricuspid apparatus may cause tricuspid regurgitation (TR). However, data regarding TR in patients with implanted PM are controversial. Our aim is to find out the degree of TR in a group of patients before and following PM implantation in a prospective manner. Methods: The study group consisted of the patients referred for implantation of permanent PM or implantable cardioverter defibrillator (ICD). All patients underwent two-dimensional and Doppler echocardiographic evaluation before and after device implantation. The severity of TR was qualitatively classified into four groups as normal or trivial, mild, moderate, or severe. All studies were reviewed for accuracy by a second independent interpreter. Results: Sixty-one patients (mean age 53 +/- 8 years, 44 male) referred for PM (n = 55) or ICD (n = 6) implantation consisted of the study population. Echocardiographic degree of TR was mild in 21 (70%), moderate in 7 (23%) and severe in 2 (7%) patients before PM implantation. Following device implantation, mild TR was noted in 23 (76%), moderate in 10 (33%), and severe in 2 (6%) cases. After the procedure, the TR severity was increased from normal/trivial to mild in 5 (16%) cases and from mild to moderate in 3 (10%). There was no worsening of the severity of TR in patients with moderate regurgitation following device implantation. The severity of TR did not change at a mean follow-up of 6 +/- 3 months. Conclusions: New or worsening TR is relatively rare after PM implantation. It is not associated with an acute worsening or clinical deterioration. But echocardiographic follow-up is recommended to monitor other complications in chronic phase.
引用
收藏
页码:391 / 394
页数:4
相关论文
共 17 条
[1]  
Cooper J W, 1989, J Am Soc Echocardiogr, V2, P56
[2]   ENTRAPMENT OF A TINED PACEMAKER ELECTRODE IN THE TRICUSPID-VALVE - A CASE-REPORT [J].
FRANDSEN, F ;
OXHOJ, H ;
NIELSEN, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (09) :1082-1083
[3]   PRESUMPTIVE TRICUSPID-VALVE MALFUNCTION INDUCED BY A PACEMAKER LEAD - CASE-REPORT AND REVIEW OF THE LITERATURE [J].
GIBSON, TC ;
DAVIDSON, RC ;
DESILVEY, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1980, 3 (01) :88-95
[4]  
GILON D, 1993, J AM SOC ECHOCARDIOG, V8, P103
[5]   REAL-TIME, TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FEATURES OF PACEMAKER PERFORATION [J].
GONDI, B ;
NANDA, NC .
CIRCULATION, 1981, 64 (01) :97-106
[6]   PERFORATION OF TRICUSPID-VALVE BY A TRANSVENOUS PACEMAKER [J].
GOULD, L ;
REDDY, CVR ;
YACOB, U ;
TEICH, M ;
DEMARTINO, A ;
DEPALMA, D ;
GOMPRECHT, RF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1974, 230 (01) :86-87
[7]   REPORT OF THE AMERICAN-SOCIETY-OF-ECHOCARDIOGRAPHY COMMITTEE-ON-NOMENCLATURE-AND-STANDARDS-IN-2-DIMENSIONAL-ECHOCARDIOGRAPHY [J].
HENRY, WL ;
DEMARIA, A ;
GRAMIAK, R ;
KING, DL ;
KISSLO, JA ;
POPP, RL ;
SAHN, DJ ;
SCHILLER, NB ;
TAJIK, A ;
TEICHHOLZ, LE ;
WEYMAN, AE .
CIRCULATION, 1980, 62 (02) :212-217
[8]   COMPLICATIONS OF PERMANENT TRANSVENOUS CARDIAC PACING - A 14-YEAR REVIEW OF ALL TRANSVENOUS PACEMAKERS INSERTED AT ONE COMMUNITY-HOSPITAL [J].
HILL, PE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03) :564-570
[9]   Transvenous pacemaker leads do not worsen tricuspid regurgitation: A prospective echocardiographic study [J].
Leibowitz, DW ;
Rosenheck, S ;
Pollak, A ;
Geist, M ;
Gilon, D .
CARDIOLOGY, 2000, 93 (1-2) :74-77
[10]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC CONTRAST ASSESSMENT OF PACING-INDUCED MITRAL REGURGITATION - RELATION TO ALTERED REGIONAL LEFT-VENTRICULAR FUNCTION [J].
MAURER, G ;
TORRES, MAR ;
CORDAY, E ;
HAENDCHEN, RV ;
MEERBAUM, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (04) :986-991