Improvement of Wear, Pitting Corrosion Resistance and Repassivation Ability of Mg-Based Alloys Using High Pressure Cold Sprayed (HPCS) Commercially Pure-Titanium Coatings

被引:17
作者
Daroonparvar, Mohammadreza [1 ]
Kasar, Ashish K. [2 ]
Farooq Khan, Mohammad Umar [3 ]
L. Menezes, Pradeep [2 ]
Kay, Charles M. [4 ]
Misra, Manoranjan [1 ]
Gupta, Rajeev K. [3 ]
机构
[1] Univ Nevada, Dept Chem & Mat Engn, Reno, NV 89501 USA
[2] Univ Nevada, Dept Mech Engn, Reno, NV 89501 USA
[3] North Carolina State Univ, Coll Engn, Dept Mat Sci & Engn, 911 Partners Way, Raleigh, NC 27695 USA
[4] ASB Ind Inc, Barberton, OH 44203 USA
基金
美国国家科学基金会;
关键词
Ti coating; cyclic potentiodynamic polarization (CPP) test; hysteresis loop; wear;
D O I
10.3390/coatings11010057
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, a compact cold sprayed (CS) Ti coating was deposited on Mg alloy using a high pressure cold spray (HPCS) system. The wear and corrosion behavior of the CS Ti coating was compared with that of CS Al coating and bare Mg alloy. The Ti coating yielded lower wear rate compared to Al coating and Mg alloy. Electrochemical impedance spectroscopy (EIS) and cyclic potentiodynamic polarization (CPP) tests revealed that CS Ti coating can substantially reduce corrosion rate of AZ31B in chloride containing solutions compared to CS Al coating. Interestingly, Ti-coated Mg alloy demonstrated negative hysteresis loop, depicting repassivation of pits, in contrast to AZ31B and Al-coated AZ31B with positive hysteresis loops where corrosion potential (E-corr) > repassivation potential (E-rp); indicating irreversible growth of pits. AZ31B and Al-coated AZ31B were most susceptible to pitting corrosion, while Ti-coated Mg alloy indicated noticeable resistance to pitting in 3.5 wt % NaCl solution. In comparison to Al coating, Ti coating considerably separated the AZ31BMg alloy surface from the corrosive electrolyte during long term immersion test for 11 days.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 66 条
[1]   Cold spraying - A materials perspective [J].
Assadi, H. ;
Kreye, H. ;
Gaertner, F. ;
Klassen, T. .
ACTA MATERIALIA, 2016, 116 :382-407
[2]   On the Improvement of AA2024 Wear Properties through the Deposition of a Cold-Sprayed Titanium Coating [J].
Astarita, Antonello ;
Rubino, Felice ;
Carlone, Pierpaolo ;
Ruggiero, Alessandro ;
Leone, Claudio ;
Genna, Silvio ;
Merola, Massimiliano ;
Squillace, Antonino .
METALS, 2016, 6 (08)
[3]  
ASTM, 2014, ASTM STANDARD G61 86
[4]  
ASTM, 2005, ASTM G133 05 STANDAR
[5]  
ASTM, 2014, ASTM E2109 01 STANDA
[6]   Introducing a composite coating containing CNTs with good corrosion properties: characterization and simulation [J].
Bakhsheshi-Rad, H. R. ;
Abdellahi, M. ;
Hamzah, E. ;
Daroonparvar, M. ;
Rafiei, M. .
RSC ADVANCES, 2016, 6 (110) :108498-108512
[7]   Fabrication and characterization of hydrophobic microarc oxidation/poly-lactic acid duplex coating on biodegradable Mg-Ca alloy for corrosion protection [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Ebrahimi-Kahrizsangi, R. ;
Daroonparvar, M. ;
Medraj, M. .
VACUUM, 2016, 125 :185-188
[8]   Improved corrosion performance of biodegradable magnesium in simulated inflammatory condition via drug-loaded plasma electrolytic oxidation coatings [J].
Bordbar-Khiabani, Aidin ;
Yarmand, Benyamin ;
Sharifi-Asl, Samin ;
Mozafari, Masoud .
MATERIALS CHEMISTRY AND PHYSICS, 2020, 239
[9]   Corrosion behaviour of thermally sprayed Al and Al/SiCp composite coatings on ZE41 magnesium alloy in chloride medium [J].
Carboneras, M. ;
Lopez, M. D. ;
Rodrigo, P. ;
Campo, M. ;
Torres, B. ;
Otero, E. ;
Rams, J. .
CORROSION SCIENCE, 2010, 52 (03) :761-768
[10]   Effect of ultrasonic cold forging technology as the pretreatment on the corrosion resistance of MAO Ca/P coating on AZ31B Mg alloy [J].
Chen, Lingling ;
Gu, Yanhong ;
Liu, Lu ;
Liu, Shujing ;
Hou, Binbin ;
Liu, Qi ;
Ding, Haiyang .
JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 635 :278-288