Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study

被引:30
作者
Mao, Li [1 ]
Liu, Tianyu [1 ]
Caracappa, Peter F. [1 ,2 ]
Lin, Hui [1 ,3 ]
Gao, Yiming [4 ]
Dauer, Lawrence T. [4 ]
Xu, X. George [1 ]
机构
[1] Rensselaer Polytech Inst, Nucl Engn Program, Troy, NY 12180 USA
[2] Columbia Univ, Dept Appl Phys & Appl Math, New York, NY 10032 USA
[3] Univ Penn, Sch Med, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[4] Mem Sloan Kettering Canc Ctr, Radiol & Med Phys, New York, NY 10065 USA
关键词
eye lens dose to radiologists; interventional radiology; Monte Carlo; phantom; RADIATION PROTECTION; PARAMETERS; CARDIOLOGY; STAFF;
D O I
10.1002/mp.13528
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify the effects of operator head posture and different types of protective eyewear on the eye lens dose to operators in interventional radiology (IR). Methods: A deformable computational human phantom, Rensselaer Polytechnic Institute (RPI) Adult Male, consisting of a high-resolution eye model, was used to simulate a radiologist who is performing an interventional radiology procedure. The radiologist phantom was deformed to a set of different head postures. Three different protective eyewear models were incorporated into the posture-deformed radiologist phantom. The eye lens dose of the radiologist was calculated using the Monte Carlo code, MCNP. Effects of the radiologist's head posture and different types of protective eyewear on eye lens doses were studied. The relationship between efficacy of protective eyewear and the radiologist's head posture was investigated. Effects of other parameters on efficacy of protective eyewear were also studied, including the angular position of the radiologist, the gap between the eyewear and the face of the radiologist, and the lead equivalent thickness. Results: The dose to both lenses decreased by 80% as the head posture moved from looking downward to looking upward. Sports wrap glasses were found to reduce doses further than the other two studied models. The efficacy of eyewear was found to be related to radiologist's head posture as well. When the radiologist was looking up, the protective eyewear almost provided no protection to both lenses. Other factors such as the face-to-eyewear distance and the lead equivalent thickness were also found to have an impact on the efficacy of protective eyewear. The dose reduction factor (DRF), defined as the ratio of the dose to the lens without protection to that with protection, decreased from 4.25 to 1.07 as the face-to-eyewear distance increased. The DRF almost doubled when the lead equivalent thickness increased from 0.07 to 0.35 mm. However, further increase in lead equivalent thickness showed little improvement in dose reduction. Conclusion: The radiologist's head posture has a significant influence on the eye lens dose in IR. Sports wrap protective eyewear which conforms to the curve of the face is essential for the radiation protection of the eye lens. However, the radiologist's head posture and other exposure parameters should be considered when evaluating the protection of the radiologist's eyes. (c) 2019 American Association of Physicists in Medicine
引用
收藏
页码:2744 / 2751
页数:8
相关论文
共 29 条
  • [1] [Anonymous], NUCL INSTRUMENTS MET
  • [2] Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry
    Caracappa, Peter F.
    Rhodes, Ashley
    Fiedler, Derek
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) : 5261 - 5275
  • [3] MONTE CARLO CALCULATIONS ON EXTREMITY AND EYE LENS DOSIMETRY FOR MEDICAL STAFF AT INTERVENTIONAL RADIOLOGY PROCEDURES
    Carinou, E.
    Ferrari, P.
    Koukorava, C.
    Krim, S.
    Struelens, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 492 - 496
  • [4] Redundant Protective Barriers: Minimizing Operator Occupational Risk
    Challa, Karthik
    Warren, Stafford G.
    Danak, Subhash
    Bates, Mark C.
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (03) : 299 - 307
  • [5] AN EPIDEMIOLOGICAL ASSESSMENT OF LENS OPACIFICATIONS THAT IMPAIRED VISION IN PATIENTS INJECTED WITH RADIUM-224
    CHMELEVSKY, D
    MAYS, CW
    SPIESS, H
    STEFANI, FH
    KELLERER, AM
    [J]. RADIATION RESEARCH, 1988, 115 (02) : 238 - 257
  • [6] Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP Commentary No. 26
    Dauer, Lawrence T.
    Ainsbury, Elizabeth A.
    Dynlacht, Joseph
    Hoel, David
    Klein, Barbara E. K.
    Maye, Donald
    Prescott, Christina R.
    Thornton, Raymond H.
    Vano, Eliseo
    Woloschak, Gayle E.
    Flannery, Cynthia M.
    Goldstein, Lee E.
    Hamada, Nobuyuki
    Tran, Phung K.
    Grissom, Michael P.
    Blakely, Eleanor A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2017, 93 (10) : 1015 - 1023
  • [7] Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens-results of the EURALOC study
    Domienik-Andrzejewska, Joanna
    Ciraj-Bjelac, Olivera
    Askounis, Panagiotis
    Covens, Peter
    Dragusin, Octavian
    Jacob, Sophie
    Farah, Jad
    Gianicolo, Emilio
    Padovani, Renato
    Teles, Pedro
    Widmark, Anders
    Struelens, Lara
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (03) : 934 - 950
  • [8] Goorley T, 2014, MCNP6 1 1 BETA RELEA
  • [9] Fifty years of the nuclear industry in Russia - Through the eyes of a physician
    Gus'kova, AK
    [J]. ATOMIC ENERGY, 1999, 87 (06) : 903 - 908
  • [10] Possible associations between computed tomography scan and cataract: The Blue Mountains Eye Study
    Hourihan, F
    Mitchell, P
    Cumming, RG
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH, 1999, 89 (12) : 1864 - 1866