Dichromatic source for the application of dual-energy tissue cancellation in mammography

被引:2
作者
Tuffanelli, A [1 ]
Fabbri, S [1 ]
Marziani, M [1 ]
Taibi, A [1 ]
Sarnelli, A [1 ]
Gambaccini, M [1 ]
机构
[1] Univ Ferrara, Dipartmento Fis, I-44100 Ferrara, Italy
来源
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING | 2002年 / 4682卷
关键词
dual energy mammography; tungsten anode x-ray tube; dichromatic x-ray beams; Bragg diffraction; mosaic crystal;
D O I
10.1117/12.465559
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel x-ray source, providing dichromatic beams for the application of dual-energy radiography, has been assembled and studied. The system works via Bragg diffraction, by monochromatizing the beam produced by a conventional W-anode x-ray tube with a mosaic crystal monochromator. The source generates a laminar beam (10 cm-high and 0.8 cm-wide), composed by two spatially superimposed quasi-monochromatic beams. The characteristics of the radiation field in terms of energy resolution and fluence have been reported, for three pairs of energies. A study of the spectra attenuated by several phantoms of breast equivalent tissue of different thicknesses shows that the optimal energy of the dichromatic beam for dual energy mammography application ranges between 18/36 keV and 18.6/37.2 keV and may be set as a function of the thickness or density of investigated tissue.
引用
收藏
页码:192 / 201
页数:4
相关论文
共 28 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   SECONDARY EXTINCTION AND NEUTRON CRYSTALLOGRAPHY [J].
BACON, GE ;
LOWDE, RD .
ACTA CRYSTALLOGRAPHICA, 1948, 1 (1-6) :303-314
[3]   DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS [J].
BOONE, JM ;
SHABER, GS ;
TECOTZKY, M .
MEDICAL PHYSICS, 1990, 17 (04) :665-675
[4]   DUAL-ENERGY DIGITAL MAMMOGRAPHY UTILIZING STIMULATED PHOSPHOR COMPUTED RADIOGRAPHY [J].
BRETTLE, DS ;
COWEN, AR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :1989-2004
[5]   X-ray characterization of breast phantom materials [J].
Byng, JW ;
Mainprize, JG ;
Yaffe, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1367-1377
[6]   Niobium/molybdenum K-edge filtration in mammography: Contrast and dose evaluation [J].
Calicchia, A ;
Gambaccini, M ;
Indovina, PL ;
Mazzei, F ;
Pugliani, L .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1717-1726
[7]  
*COMP IM REF SYST, 1995, MODEL A, V12, P1
[8]   Focusing properties of mosaic crystals [J].
del Río, MS ;
Gambaccini, M ;
Pareschi, G ;
Taibi, A ;
Tuffanelli, A ;
Freund, A .
CRYSTAL AND MULTILAYER OPTICS, 1998, 3448 :246-255
[9]   XOP:: Recent developments [J].
del Río, MS ;
Dejus, RJ .
CRYSTAL AND MULTILAYER OPTICS, 1998, 3448 :340-345
[10]  
FREUND A, 1992, SPIE P, V1740, P58