Biomechanical investigation of four different fixation techniques in sacrum Denis type II fracture with low bone mineral density

被引:30
作者
Acklin, Yves P. [1 ]
Zderic, Ivan [1 ]
Richards, Robert G. [1 ]
Schmitz, Paul [2 ]
Gueorguiev, Boyko [1 ]
Grechenig, Stephan [2 ]
机构
[1] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
[2] Univ Klinikum Regensburg, Klin & Poliklin Unfallchirurg, Franz Josef Strauss Allee 11, D-93053 Regensburg, Bayern, Germany
关键词
fragility sacrum fracture; posterior sacral plating; triangular fixation; ILIOSACRAL SCREW FIXATION; TRIANGULAR OSTEOSYNTHESIS; FRAGILITY FRACTURES; OSTEOPOROSIS; INSERTION; INJURIES; LOCKING;
D O I
10.1002/jor.23798
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
With increasing life expectancy, fragility fractures of the pelvic ring are seen more frequently. Although their osteosynthesis can be very challenging, specific biomechanical studies for investigation of the fixation stability are still lacking. The aim of this study was to biomechanically evaluate four different fixation methods for sacrum Denis type II fractures in osteoporotic bone. Unstable Denis type II vertical sacrum fractures were created in 16 human pelves. Their osteosynthesis was performed with one sacro-iliac screw, posterior sacral plating, triangular fixation, or spino-pelvic fixation. For that purpose, each pelvis was randomly assigned to two paired groups for treatment with either SI-screw/posterior sacral plating or triangular fixation/spino-pelvic fixation. Each hemi-pelvis was cyclically tested under progressively increasing axial compression. Relative interfragmentary movements were investigated via optical motion tracking analysis. Axial stiffness of triangular fixation was significantly higher versus posterior sacral plating and spino-pelvic fixation (p0.022), but not significantly different in comparison to SI-screw fixation (p=0.337). Cycles to 2, 3, 5, and 8mm fracture displacement, as well as to 3 degrees, 5 degrees, and 8 degrees gap angle at the fracture site were significantly higher for triangular fixation compared to all other groups (p0.041). Main failure mode for all osteosynthesis techniques was screw cutting through the bone, leading loss of fixation stability. From a biomechanical point of view, triangular fixation in sacrum Denis type II fractures demonstrated less interfragmentary movements and should be considered in unstable fragility fractures of the sacrum. (c) 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1624-1629, 2018.
引用
收藏
页码:1624 / 1629
页数:6
相关论文
共 24 条
[1]  
Acklin YP, 2015, OPER ORTHOP TRAUMATO, V27, P74, DOI 10.1007/s00064-014-0307-2
[2]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[3]   Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025 [J].
Burge, Russel ;
Dawson-Hughes, Bess ;
Solomon, Daniel H. ;
Wong, John B. ;
King, Alison ;
Tosteson, Anna .
JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (03) :465-475
[4]  
DENIS F, 1988, CLIN ORTHOP RELAT R, P67
[5]   Transsacral Osseous Corridor Anatomy Is More Amenable To Screw Insertion In Males: A Biomorphometric Analysis of 280 Pelves [J].
Gras, Florian ;
Gottschling, Heiko ;
Schroeder, Manuel ;
Marintschev, Ivan ;
Hofmann, Gunther O. ;
Burgkart, Rainer .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (10) :2304-2311
[6]   Angular Stability Potentially Permits Fewer Locking Screws Compared With Conventional Locking in Intramedullary Nailed Distal Tibia Fractures: A Biomechanical Study [J].
Gueorguiev, Boyko ;
Ockert, Ben ;
Schwieger, Karsten ;
Waehnert, Dirk ;
Lawson-Smith, Matthew ;
Windolf, Markus ;
Stoffel, Karl .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) :340-346
[7]   THE EFFECT OF THREAD LENGTH AND LOCATION ON EXTRACTION STRENGTHS OF ILIOSACRAL LAG SCREWS [J].
KRAEMER, W ;
HEARN, T ;
TILE, M ;
POWELL, J .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (01) :5-9
[8]   Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues [J].
Liu, Helen ;
Holt, Cathy ;
Evans, Sam .
JOURNAL OF BIOMECHANICS, 2007, 40 (01) :210-214
[9]   Variations in Sacral Morphology and Implications for Iliosacral Screw Fixation [J].
Miller, Anna N. ;
Routt, Milton L. Chip, Jr. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (01) :8-16
[10]   Comparison of Two-transsacral-screw Fixation Versus Triangular Osteosynthesis for Transforaminal Sacral Fractures [J].
Min, Kyong S. ;
Zamorano, David P. ;
Wahba, George M. ;
Garcia, Ivan ;
Bhatia, Nitin ;
Lee, Thay Q. .
ORTHOPEDICS, 2014, 37 (09) :e754-e760