The effect of applied sensor contact force on pulse transit time

被引:48
作者
Teng, X. F. [1 ]
Zhang, Y. T. [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Joint Res Ctr Biomed Engn, Shatin, Hong Kong, Peoples R China
关键词
contact force; photoplethysmogram; pulse transit time;
D O I
10.1088/0967-3334/27/8/002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pulse transit time (PTT) is usually determined as the time interval between the peak of the electrocardiogram (ECG) R wave and a characteristic point of the peripheral pulse measured by photoplethysmography. However, it was found that the photoplethysmogram (PPG) is affected by the contact force between the photoplethysmographic sensor and the measurement site, i.e. finger. Therefore, we hypothesized that the PTT may be altered by the applied sensor contact force. An ECG and PPG were recorded simultaneously from 30 healthy subjects using 12 magnitudes of contact force (0.1 N-1.8 N). Three characteristic points of the PPG were selected to determine the PTT, including the points near the foot (PTT1), on the systole phase (PTT2) and near the peak (PTT3). Both PTT1 and PTT2 increased significantly (p = 0.014 for PTT1 and p = 0.038 for PTT2) with the sensor contact force until the transmural force reached -0.1 N. With further increase in the contact force, they kept at an almost constant level. Such a changing trend was not found in PTT3. The results of this study suggest that the applied sensor contact force should be carefully controlled in PTT measurement to avoid diminishing its value as a diagnostic tool.
引用
收藏
页码:675 / 684
页数:10
相关论文
共 44 条
[11]   OSCILLOMETRIC DETERMINATION OF DIASTOLIC, MEAN AND SYSTOLIC BLOOD-PRESSURE - A NUMERICAL-MODEL [J].
FORSTER, FK ;
TURNEY, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (04) :359-364
[12]  
FRANCHI D, 1996, COMPUT CARDIOL, V23, P397
[13]   ON A NON-INVASIVE EVALUATION OF PULSE-WAVE VELOCITY IN HUMAN PERIPHERAL ARTERIES [J].
GIZDULICH, P .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1984, 5 (01) :33-36
[14]   A CRITIQUE - RELATIONSHIP OF TIME DERIVATIVE OF PRESSURE TO BLOOD FLOW [J].
GREENFIELD, JC ;
FRY, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (06) :1141-+
[15]   ON THE PRESSURE-VOLUME RELATIONSHIP IN CIRCULATORY ELEMENTS [J].
HARDY, HH ;
COLLINS, RE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (05) :565-570
[16]  
Hertzman AB, 1937, P SOC EXP BIOL MED, V37, P529
[17]   REPEATABILITY OF PERIPHERAL PULSE MEASUREMENTS ON EARS, FINGERS AND TOES USING PHOTOELECTRIC PLETHYSMOGRAPHY [J].
JAGO, JR ;
MURRAY, A .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (04) :319-329
[18]   AN ARTERIAL TO PERIPHERAL PULSE-WAVE VELOCITY MEASURE [J].
JENNINGS, JR ;
CHOI, S .
PSYCHOPHYSIOLOGY, 1983, 20 (04) :410-418
[19]   PULSE TRANSIT-TIME AND BLOOD-PRESSURE - AN INTENSIVE ANALYSIS [J].
LANE, JD ;
GREENSTADT, L ;
SHAPIRO, D ;
RUBINSTEIN, E .
PSYCHOPHYSIOLOGY, 1983, 20 (01) :45-49
[20]   PRESSURE DIAMETER RELATIONSHIPS OF SEGMENTS OF HUMAN FINGER ARTERIES [J].
LANGEWOUTERS, GJ ;
ZWART, A ;
BUSSE, R ;
WESSELING, KH .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1986, 7 (01) :43-56