Intramedullary devices fixation versus plate fixation for adult displaced mid-shaft clavicle fractures: an update meta-analysis

被引:0
作者
Zhang, Xiao [1 ,2 ]
Geng, Tao [1 ,2 ,3 ]
Xue, Haitao [4 ]
Zhang, Wenqiang [4 ]
Yin, Yingchao [1 ,2 ,3 ]
Jiang, Zhen [5 ]
Hu, Zeqing [6 ]
Luo, Tong [1 ,2 ]
Zhang, Guisheng [1 ]
Xu, Yi [1 ,2 ,3 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Orthoped Surg, 139 Ziqiang Rd, Shijiazhuang 050051, Peoples R China
[2] Key Lab Biomech Hebei Prov, Shijiazhuang, Peoples R China
[3] Orthoped Res Inst Hebei Prov, Shijiazhuang, Peoples R China
[4] Peoples Hosp Quzhou Country, Dept Orthoped Surg, Handan, Peoples R China
[5] Tradit Chinese Med Hosp Hebei Prov, Dept Orthoped Surg, Shijiazhuang, Peoples R China
[6] Peoples Hosp Pingxiang Country, Dept Emergency, Xingtai, Peoples R China
关键词
Intramedullary; plate; mid-shaft clavicle fractures; meta-analysis; MIDCLAVICULAR FRACTURES; PIN;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Nowadays, the exact efficacy of intramedullary devices fixation and plate fixation for adult displaced midshaft clavicle fractures (DMCF) is still debated. This study aims to re-assess the functional outcomes and complications of the two optimal surgical approaches. Cochrane Central Register of Controlled Trials, EMABASE, and PubMed databases were searched for the literature that studied the efficacy of intramedullary devices fixation versus plate fixation for acute DMCF before August 2015. This meta-analysis focused on the Constant Shoulder Score, Oxford Shoulder Score and the incidence of infection, implant irritation, implant failure and nonunion. Revman 5.2 was used to analyze the difference between two approaches. Six trials altogether including 335 fractures were eligible, in which 163 clavicle fractures were treated with intramedullary repair and 172 with plates. The final results of our study indicate that the Constant Shoulder Score is significantly higher (MD, 2.64; 95% CI, 1.42 to 3.87; P< 0.05) and the infection rate is slightly lower (RR, 0.25; 95% CI, 0.07 to 0.96; P< 0.05) in intramedullary devices fixation group than the plate fixation group. And the occurrence of other adverse effects remains the same. The present meta-analysis indicates that intramedullary devices fixation could improve the functional recovery and reduce the infection rate. The intramedullary approach does not yield the irritation rate significantly.
引用
收藏
页码:1840 / 1846
页数:7
相关论文
共 21 条
[1]   Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures [J].
Assobhi J.E.H. .
Journal of Orthopaedics and Traumatology, 2011, 12 (4) :185-192
[2]   A systematic review of plate versus intramedullary fixation in the treatment of midshaft clavicle fractures [J].
Barlow, T. ;
Beazley, J. ;
Barlow, D. .
SCOTTISH MEDICAL JOURNAL, 2013, 58 (03) :163-167
[3]   Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures [J].
Bernstein, Joseph .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (08) :1866-1866
[4]   Current Treatment Concepts for Mid-Shaft Fractures of the Clavicle - Results of a Prospective Multicentre Study [J].
Boehme, J. ;
Bonk, A. ;
Bacher, G. O. ;
Wilharm, A. ;
Hoffmann, R. ;
Josten, C. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2011, 149 (01) :68-76
[5]   Biomechanical Analysis of Fixation of Middle Third Fractures of the Clavicle [J].
Drosdowech, Darren S. ;
Manwell, Stuart E. E. ;
Ferreira, Louis M. ;
Goel, Danny P. ;
Faber, Kenneth J. ;
Johnson, James A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) :39-43
[6]   Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials [J].
Duan, Xin ;
Zhong, Gang ;
Cen, Shiqiang ;
Huang, Fuguo ;
Xiang, Zhou .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (06) :1008-1015
[7]   Locked intramedullary fixation vs plating for displaced and shortened mid-shaft clavicle fractures: A randomized clinical trial [J].
Ferran, Nicholas A. ;
Hodgson, Paul ;
Vannet, Nicola ;
Williams, Rhys ;
Evans, Richard O. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (06) :783-789
[8]   Is intramedullary nailing more effective than non-operative treatment in adults with displaced middle-third clavicle fractures? [J].
Hill C.E. .
Journal of Orthopaedics and Traumatology, 2014, 15 (3) :155-164
[9]   Closed treatment of displaced middle-third fractures of the clavicle gives poor results [J].
Hill, JM ;
McGuire, MH ;
Crosby, LA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04) :537-539
[10]   Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review [J].
Houwert, R. Marijn ;
Wijdicks, Frans-Jasper ;
Bisschop, Charlotte Steins ;
Verleisdonk, Egbert-Jan ;
Kruyt, Moyo .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) :579-585