Comparison of distal radius fracture intra-articular step reduction with volar locking plates and K wires: a retrospective review of quality and maintenance of fracture reduction

被引:9
作者
Johnson, N. A. [1 ]
Dias, J. J. [1 ]
Wildin, C. J. [1 ]
Cutler, L. [1 ]
Bhowal, B. [1 ]
Ullah, A. S. [1 ]
机构
[1] Leicester Royal Infirm, Infirm Sq, Leicester LE1 5WW, Leics, England
关键词
Distal radius fracture; volar locking plate; Kirschner wires; wrist fracture; X-RAY RADIOGRAMMETRY; PERCUTANEOUS FIXATION; FUNCTIONAL OUTCOMES; INTERNAL-FIXATION; METACARPAL INDEX; PREDICTS HIP; YOUNG-ADULTS; COMPLICATIONS; DISPLACEMENT; WRIST;
D O I
10.1177/1753193416669502
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study investigated the accuracy and maintenance of reduction of intra-articular steps achieved with closed reduction and percutaneous K wires and open reduction and a volar locking plate for the treatment of intra-articular distal radius fractures. We performed a retrospective review of 359 patients with an intra-articular fracture of their distal radius. Multivariate linear regression was undertaken to investigate the influence of multiple variables such as age, gender, initial displacement and treatment method on reduction despite differences between groups. A total of 36% of patients treated with K wires and 29% with volar locking plate had a step greater than or equal to 1mm present on the first post-operative radiograph. A total of 23% treated with K wires and 28% with volar locking plate had a residual step of 1mm or more on the last available radiograph. There was no difference identified between the two techniques for quality of initial reduction or persisting step on the last available radiographs. Step behaviour and further reduction of step post-operatively was similar for both treatment methods. Initial displacement and increased age influenced initial reduction. Initial fracture displacement shown radiologically was the only variable identified that influenced the persistence of a step on post-operative radiographs. Level of evidence: IV
引用
收藏
页码:144 / 150
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 2003, COCHRANE DB SYST REV
[2]   Unstable extra-articular fractures of the distal radius - A prospective, randomised study of immobilisation in a cast versus supplementary percutaneous pinning [J].
Azzopardi, T ;
Ehrendorfer, S ;
Coulton, T ;
Abela, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06) :837-840
[3]   Displaced intra-articular fractures of the distal radius: The effect of fracture displacement on contact stresses in a cadaver model [J].
Baratz, ME ;
Jardins, JDD ;
Anderson, DD ;
Imbriglia, JE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (02) :183-188
[4]   Digital X-ray radiogrammetry predicts hip, wrist and vertebral fracture risk in elderly women: A prospective analysis from the study of osteoporotic fractures [J].
Bouxsein, ML ;
Palermo, L ;
Yeung, C ;
Black, DM .
OSTEOPOROSIS INTERNATIONAL, 2002, 13 (05) :358-365
[5]   Displaced intra-articular fractures of the distal aspect of the radius - Long-term results in young adults after open reduction and internal fixation [J].
Catalano, LW ;
Cole, RJ ;
Gelberman, RH ;
Evanoff, BA ;
Gilula, LA ;
Borrelli, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1290-1302
[6]   Predictors of functional outcomes after surgical treatment of distal radius fractures [J].
Chung, Kevin C. ;
Kotsis, Sandra V. ;
Kim, H. Myra .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (01) :76-83
[7]   Treatment of unstable distal radial fractures with the volar locking plating system [J].
Chung, Kevin C. ;
Watt, Andrew J. ;
Kotsis, Sandra V. ;
Margaliot, Zvi ;
Haase, Steven C. ;
Kim, Myra .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2687-2694
[8]  
Cole RJ, 1997, J HAND SURG-AM, V22A, P792
[9]   Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial [J].
Costa, Matthew L. ;
Achten, Juul ;
Parsons, Nick R. ;
Rangan, Amar ;
Griffin, Damian ;
Tubeuf, Sandy ;
Lamb, Sarah E. .
BMJ-BRITISH MEDICAL JOURNAL, 2014, 349
[10]   A revolution in the management of the distal radius? [J].
Downing, N. D. ;
Karantana, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1271-1275