Liquid-Based Cytology in Fine-Needle Aspirates of the Thyroid and Breast

被引:5
|
作者
Kim, Ji-Young [1 ]
机构
[1] CHA Univ, CHA Gangnam Med Ctr, Dept Pathol, Seoul, South Korea
关键词
Cytology; Fine needle aspiration; Thyroid gland; Breast; THINPREP(R) TECHNIQUE; CONVENTIONAL SMEAR; LESIONS; SPECIMENS; DIAGNOSIS; ARTIFACTS; ACCURACY; PITFALLS; UTILITY;
D O I
10.4132/KoreanJPathol.2009.43.2.99
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Liquid-based cytology (LBC) is becoming more widely used in analyzing the fine-needle aspirates (FNAs) from various organs, including the thyroid and breast. Compared to the conventional smear, LBC can achieve more consistent cellularity and evenly distributed mono-layered cell preparations and it can diminish the obscuring background, thus lower the rate of 'unsatisfactory' specimens. The cytomorphological details are better preserved with LBC, and it also provides the opportunity to perform ancillary tests such as immunocytochemical or molecular studies. It requires less time and manpower for screening, too. Yet there are drawbacks for the liquid-based technique. The cell clusters tend to be more fragmented and they often lose their typical structural characteristics that may have helped in making a diagnosis. Some useful background material such as colloid and mucin is diminished. However, LBC still retains many of the cytological features of a conventional smear and possesses unique characteristics as well. Here, some of the typical cytological findings of the liquid-based technique for FNA of the thyroid and breast are reviewed. Experience, and awareness of the cylomorphological characteristics of liquid-based technique in non-gynecological aspirates is crucial for correct interpretation.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [21] Thyroid fine-needle aspiration cytology: Is there a place to virtual cytology?
    Gerhard, Rene
    Teixeira, Sofia
    da Rocha, Adriana Gaspar
    Schmitt, Fernando
    DIAGNOSTIC CYTOPATHOLOGY, 2013, 41 (09) : 793 - 798
  • [22] Expression of p63 immunostaining in liquid-based cytology (BD SurePath) of breast fine-needle aspiration
    Osugi, Masumi
    Kinoshita, Kosei
    Sugita, Atsuro
    Kito, Katsumi
    Maeda, Toshiharu
    DIAGNOSTIC CYTOPATHOLOGY, 2018, 46 (10) : 845 - 852
  • [23] Thyroid Fine-Needle Aspiration Cytology
    Eilers, Stan G.
    LaPolice, Paula
    Mukunyadzi, Perkins
    Kapur, Umesh
    Spiczka, Amy Wendel
    Shah, Ajay
    Saleh, Husain
    Adeniran, Adebowale
    Nunez, Amberly
    Balachandran, Indra
    Clark, Jennifer J.
    Lemon, Larry
    CANCER CYTOPATHOLOGY, 2014, 122 (10) : 745 - 750
  • [24] Utility of manual liquid-based cytology and conventional smears in the evaluation of various fine-needle aspiration samples
    Arul, P.
    JOURNAL OF CYTOLOGY, 2016, 33 (04) : 177 - 181
  • [25] UbcH10 Expression on Thyroid Fine-Needle Aspirates
    Guerriero, Eliana
    Ferraro, Angelo
    Desiderio, Doriana
    Pallante, Pierlorenzo
    Berlingieri, Maria Teresa
    Iaccarino, Antonino
    Palmieri, Emiliano
    Palombini, Lucio
    Fusco, Alfredo
    Troncone, Giancarlo
    CANCER CYTOPATHOLOGY, 2010, 118 (03) : 157 - 165
  • [26] Subclassification of "Atypia of Undetermined Significance" in Thyroid Fine-Needle Aspirates
    Wu, Howard H.
    Inman, Ashley
    Cramer, Harvey M.
    DIAGNOSTIC CYTOPATHOLOGY, 2014, 42 (01) : 23 - 29
  • [27] Primary pure squamous cell carcinoma of the breast diagnosed by fine-needle aspiration cytology:: A case study using liquid-based cytology
    Vera-Alvarez, J.
    Garcia-Prats, M. D.
    Marigil-Gomez, M.
    Abascal-Agorreta, M.
    Lopez-Lopez, J. I.
    Ramon-Cajal, J. M.
    DIAGNOSTIC CYTOPATHOLOGY, 2007, 35 (07) : 429 - 432
  • [28] Adequacy of Fine-Needle Aspiration Cytology for Breast Lesions: The SurePath (R) Liquid-Based Technique versus Conventional Smears
    Eleuterio, Jose, Jr.
    Aragao, Alessa
    Magno Cavalcante, Diane Isabelle
    ACTA CYTOLOGICA, 2015, 59 (03) : 253 - 257
  • [29] Diagnostic accuracy of fine-needle aspiration cytology of the breast in Japan: Report from the Working Group on the Accuracy of Breast Fine-Needle Aspiration Cytology of the Japanese Society of Clinical Cytology
    Yamaguchi, Rin
    Tsuchiya, Shin-Ichi
    Koshikawa, Takashi
    Ishihara, Akinori
    Masuda, Shinobu
    Maeda, Ichiro
    Takimoto, Masafumi
    Kawamoto, Masashi
    Satoh, Haruaki
    Narita, Michihiko
    Itoh, Hitoshi
    Kitamura, Takashi
    Tsuda, Yoshiko
    Ogane, Naoki
    Abe, Eiji
    Ikeda, Katsuhide
    Nakamura, Takeshi
    Kamaguchi, Harumi
    Tokoro, Yoshiro
    ONCOLOGY REPORTS, 2012, 28 (05) : 1606 - 1612
  • [30] ANALYSIS OF THE CAUSES OF FALSE-NEGATIVE CYTOLOGY REPORTS ON BREAST-CANCER FINE-NEEDLE ASPIRATES
    CARIAGGI, MP
    BULGARESI, P
    CONFORTINI, M
    BONARDI, L
    MADDAU, C
    MATUCCI, N
    CIATTO, S
    CYTOPATHOLOGY, 1995, 6 (03) : 156 - 161