Direct current contamination of kilohertz frequency alternating current waveforms

被引:30
作者
Franke, Manfred [1 ]
Bhadra, Niloy [1 ]
Bhadra, Narendra [1 ]
Kilgore, Kevin [1 ,2 ,3 ]
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] MetroHlth Med Ctr, Cleveland, OH 44109 USA
[3] Louis Stokes Cleveland Dept Vet Affairs Med Ctr, Cleveland, OH 44106 USA
关键词
Kilohertz high frequency alternating current; Nerve block; KHFAC; HFAC; Direct current; DC in KHFAC; CHRONIC ELECTRICAL-STIMULATION; CONDUCTION BLOCK; AUDITORY-NERVE; PERIPHERAL-NERVE; SELECTIVE BLOCK; BALANCED STIMULI; PUDENDAL NERVE; SPINAL-CORD; ELECTRODES; PARAMETERS;
D O I
10.1016/j.jneumeth.2014.04.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Kilohertz frequency alternating current (KHFAC) waveforms are being evaluated in a variety of physiological settings because of their potential to modulate neural activity uniquely when compared to frequencies in the sub-kilohertz range. However, the use of waveforms in this frequency range presents some unique challenges regarding the generator output. In this study we explored the possibility of undesirable contamination of the KHFAC waveforms by direct current (DC). We evaluated current- and voltage-controlled KHFAC waveform generators in configurations that included a capacitive coupling between generator and electrode, a resistive coupling and combinations of capacitive with inductive coupling. Our results demonstrate that both voltage- and current-controlled signal generators can unintentionally add DC-contamination to a KHFAC signal, and that capacitive coupling is not always sufficient to eliminate this contamination. We furthermore demonstrated that high value inductors, placed in parallel with the electrode, can be effective in eliminating DC-contamination irrespective of the type of stimulator, reducing the DC contamination to less than 1 mu A. This study highlights the importance of carefully designing the electronic setup used in KHFAC studies and suggests specific testing that should be performed and reported in all studies that assess the neural response to KHFAC waveforms. Published by Elsevier B.V.
引用
收藏
页码:74 / 83
页数:10
相关论文
共 28 条
[1]   HISTOLOGIC AND PHYSIOLOGIC EVALUATION OF ELECTRICALLY STIMULATED PERIPHERAL-NERVE - CONSIDERATIONS FOR THE SELECTION OF PARAMETERS [J].
AGNEW, WF ;
MCCREERY, DB ;
YUEN, TGH ;
BULLARA, LA .
ANNALS OF BIOMEDICAL ENGINEERING, 1989, 17 (01) :39-60
[2]   High-frequency electrical conduction block of mammalian peripheral motor nerve [J].
Bhadra, N ;
Kilgore, KL .
MUSCLE & NERVE, 2005, 32 (06) :782-790
[3]   Selective block of external anal sphincter activation during electrical stimulation of the sacral anterior roots in a canine model [J].
Bhadra, N ;
Mortimer, JT .
NEUROGASTROENTEROLOGY AND MOTILITY, 2005, 17 (05) :721-726
[4]   Direct current electrical conduction block of peripheral nerve [J].
Bhadra, N ;
Kilgore, KL .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (03) :313-324
[5]   Bladder voiding by combined high frequency electrical pudendal nerve block and sacral root stimulation [J].
Boger, Adam ;
Bhadra, Narendra ;
Gustafson, Kenneth J. .
NEUROUROLOGY AND URODYNAMICS, 2008, 27 (05) :435-439
[6]  
BOWMAN BR, 1986, APPL NEUROPHYSIOL, V49, P121
[7]  
Chae J, 2000, Phys Med Rehabil Clin N Am, V11, P209
[8]  
Chae J., 2000, Phys Med Rehabil Clin N Am, V11, px
[9]   Neural stimulation and recording electrodes [J].
Cogan, Stuart F. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 :275-309
[10]   MUSCLE-SELECTIVE BLOCK USING INTRAFASCICULAR HIGH-FREQUENCY ALTERNATING CURRENT [J].
Dowden, Brett R. ;
Wark, Heather A. C. ;
Normann, Richard A. .
MUSCLE & NERVE, 2010, 42 (03) :339-347