Outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent in patients with chronic total occlusions: A multicenter registry

被引:6
作者
Azzalini, Lorenzo [1 ]
Demir, Ozan M. [1 ]
Gasparini, Agabriele L. [2 ]
Grancini, Luca [3 ]
La Manna, Alessio [4 ]
Ojeda, Soledad [5 ]
Benincasa, Susanna [1 ]
Bellini, Barbara [1 ]
Poletti, Enrico [1 ]
Maccagni, Davide [1 ]
Soldi, Margherita [2 ]
Lannetta, Loredana [3 ]
Trabattoni, Daniela [3 ,6 ]
Gravina, Giacomo [4 ]
Hidalgo, Francisco [5 ]
Giannini, Francesco [1 ]
Pan, Manuel
Tamburino, Corrado [4 ]
Bartorelli, Antonio L. [3 ,6 ]
Reimers, Bernhard [2 ]
Godino, Cosmo [1 ]
Carlino, Mauro [1 ]
Colombo, Antonio [1 ]
机构
[1] Ist Sci San Raffaele, Cardiothorac Vasc Dept, Intervent Cardiol Div, Via Olgettina 60, I-20132 Milan, Italy
[2] Humanitas Res Hosp, Invas Cardiol & Hemodynam, Rozzano, Italy
[3] IRCCS Ctr Cardiol Monzino, Dept Cardiovasc Sci, Milan, Italy
[4] Univ Catania, Ferrarotto Hosp, Div Cardiol, Catania, Italy
[5] Univ Cordoba, Reim Sofia Hosp, Intervent Cardiol, Cordoba, Spain
[6] Univ Milan, Milan, Italy
关键词
Chronic total occlusion; Drug-eluting stents; Bioresorbable polymer; Percutaneous coronary intervention; PERCUTANEOUS CORONARY INTERVENTION; CLINICAL-EVALUATION; DURABLE POLYMER; TRIAL; SYSTEM; LESIONS; ARTERY;
D O I
10.1016/j.ijcard.2018.01.115
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We aimed to evaluate the mid-term outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent (BP-SES) in chronic total occlusion (CTO) percutaneous coronary intervention (PCI), as compared with durable-polymer everolimus-eluting stents (EES). Methods: We compiled a multicenter registry of patients undergoing CTO recanalization followed by BP-SES or EES implantation. The primary endpoint was the incidence of target-lesion failure (TLF, a composite of cardiac death, target-vessel myocardial infarction, and target-lesion revascularization) at one year. Propensity score matching (PSM) was used to adjust for case mix. Results: Overall, 413 patients were included (BP-SES n = 242, EES n = 171). PSM resulted in 131 matched pairs, which represented the subject of the main analysis. Antegrade wire escalation was the most successful crossing technique (66% vs. 63%, p = 0.98) in both the BP-SES and EES groups, respectively. Procedural success rates were similar between groups (BP-SES 96% vs. EES 93%, p = 0.24). At one-year follow-up, there were no differences in the primary endpoint of TLF (5.7% vs. 8.3%, p = 0.44), and in cardiac death (0.9% vs. 2.8%, p = 0.32), target-vessel myocardial infarction (0.9% vs 1.9%, p = 0.57), target-lesion revascularization (3.7% vs 3.7%, p = 0.99), or stent thrombosis (0.9% vs. 1.9%, P = 0.57), in BP-SES vs. EES, respectively. Conclusions: Patients undergoing CTO PCI with BP-SES suffer a low rate of TLF at one-year follow-up, which is similar to that of subjects treated with durable-polymer EES. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
[11]   First-in-man randomised comparison of a novel sirolimus-eluting stent with abluminal biodegradable polymer and thin-strut cobalt-chromium alloy: INSPIRON-I trial [J].
Ribeiro, Expedito E. ;
Campos, Carlos M. ;
Ribeiro, Henrique B. ;
Lopes, Augusto C. ;
Esper, Rodrigo B. ;
Meirelles, George X. ;
Perin, Marco A. ;
Abizaid, Alexandre ;
Lemos, Pedro A. .
EUROINTERVENTION, 2014, 9 (12) :1380-1384
[12]   Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction [J].
Gasior, Pawel ;
Gierlotka, Marek ;
Szczurek-Katanski, Krzysztof ;
Osuch, Marcin ;
Roleder, Magda ;
Hawranek, Michal ;
Gasior, Mariusz ;
Wojakowski, Wojciech ;
Polonski, Lech .
POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (04) :347-355
[13]   Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trial [J].
Ghione, Matteo ;
Wykrzykowska, Joanna J. ;
Windecker, Stephan ;
Serruys, Patrick W. ;
Buszman, Pawel ;
Linke, Axel ;
Sohn, Hae Young ;
Corti, Roberto ;
Antoni, Diethmar ;
Wijns, William ;
Estevez-Loureiro, Rodrigo ;
Morice, Marie-Claude ;
Van Es, Gerrit-Anne ;
van Geuns, Robert Jan ;
Juni, Peter ;
Eerdmans, Pedro ;
De Vries, Ton ;
Konik, Stephanie ;
Di Mario, Carlo .
CARDIOLOGY JOURNAL, 2016, 23 (06) :626-636
[14]   A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry [J].
Zheng, Bo ;
Liu, Yi ;
Zhang, Ruining ;
Yang, Wangwei ;
Su, Fangju ;
Wang, Rutao ;
Chen, Dapeng ;
Shen, Guidong ;
Qiu, Yumin ;
Wang, Lianmin ;
Chen, Chang ;
Wu, Zhongwei ;
Li, Fei ;
Li, Jiayi ;
Li, Chengxiang ;
Gao, Chao ;
Tao, Ling .
CHINESE MEDICAL JOURNAL, 2023, 136 (15) :1848-1854
[15]   Angiographic and clinical outcomes after recanalization of coronary chronic total occlusions with the Orsiro sirolimus-eluting stent compared with the resolute zotarolimus-eluting stent [J].
Markovic, Sinisa ;
Luetzner, Michael ;
Dragomir, Sergiu ;
Rottbauer, Wolfgang ;
Woehrle, Jochen .
CORONARY ARTERY DISEASE, 2017, 28 (05) :376-380
[16]   Efficacy and Safety of Sirolimus-Eluting Stent With Biodegradable Polymer UltimasterTM in Unselected Korean Population: A Multicenter, Prospective, Observational Study From Korean Multicenter Ultimaster Registry [J].
Park, Soohyung ;
Rha, Seung-Woon ;
Choi, Byoung Geol ;
Seo, Jae -Bin ;
Choi, Ik Jun ;
Woo, Sung-Il ;
Kim, Soo -Han ;
Ahn, Tae Hoon ;
Kim, Jae Sang ;
Her, Ae-Young ;
Ahn, Ji-Hun ;
Lee, Han Cheol ;
Choi, Jaewoong ;
Byon, Jin Soo ;
Sinurat, Markz R. M. P. ;
Choi, Se Yeon ;
Cha, Jinah ;
Hyun, Su Jin ;
Choi, Cheol Ung ;
Park, Chang Gyu .
KOREAN CIRCULATION JOURNAL, 2024, 54 (06) :339-350
[17]   First report of the use of long-tapered sirolimus-eluting coronary stent for the treatment of chronic total occlusions with the hybrid algorithm [J].
Zivelonghi, Carlo ;
van Kuijk, Jan P. ;
Nijenhuis, Vincent ;
Poletti, Enrico ;
Suttorp, Maarten J. ;
van der Heyden, Jan A. S. ;
Eefting, Frank D. ;
Rensing, Benno J. ;
ten Berg, Jurrien M. ;
Azzalini, Lorenzo ;
van den Brink, Floris S. ;
Ribichini, Flavio ;
Colombo, Antonio ;
Henriques, Jose P. S. ;
Agostoni, Pierfrancesco .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) :E299-E307
[18]   Serial Angiographic Follow-Up after Successful Implantation of Sirolimus, Paclitaxel and Everolimus-Eluting Stent for Chronic Total Occlusions: Multicenter Registry in Asia [J].
Nakamura, Sunao ;
Ogawa, Hisao ;
Bae, Jang-Ho ;
Cahyadi, Yeo H. ;
Udayachalerm, Wasan ;
Tresukosol, Damras ;
Tansuphaswadikul, Sudaratana .
CIRCULATION, 2010, 122 (21)
[19]   Five-year outcomes of a drug-coated polymer-free biolimus-eluting stent versus an ultrathin-strut biodegradable-polymer sirolimus-eluting stent [J].
Jensen, Lisette Okkels ;
Jakobsen, Lars ;
Eftekhari, Ashkan ;
Ellert-Gregersen, Julia ;
Stottrup, Nicolaj Brejnholt ;
Engstrom, Thomas ;
Kahlert, Johnny ;
Freeman, Philip ;
Veien, Karsten Tange ;
Jensen, Rebekka Vibjerg ;
Lassen, Jens Flensted ;
Junker, Anders ;
Christiansen, Evald Hoj .
EUROINTERVENTION, 2025, 21 (11) :e617-e628
[20]   Safety and Effectiveness of the SVELTE Fixed-Wire and Rapid Exchange Bioresorbable-Polymer Sirolimus-Eluting Coronary Stent Systems for the Treatment of Atherosclerotic Lesions Results of the OPTIMIZE Randomized Study [J].
Kereiakes, Dean J. ;
Feldman, Robert L. ;
Ijsselmuiden, A. J. J. ;
Saito, Shigeru ;
Amoroso, Giovanni ;
Zidar, James P. ;
Wong, S. Chiu ;
Stella, Pieter ;
Yakubov, Steven ;
Lasala, John ;
Cohen, David J. ;
Doros, Gheorghe ;
Cutlip, Donald E. ;
Rao, Sunil, V .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (09) :E010609