Real-time visualization and interaction with static and live optical coherence tomography volumes in immersive virtual reality

被引:26
作者
Draelos, Mark [1 ]
Keller, Brenton [1 ]
Viehland, Christian [1 ]
Carrasco-Zevallos, Oscar M. [1 ]
Kuo, Anthony [1 ,2 ]
Izatt, Joseph [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
HEADS-UP DISPLAY; VITREORETINAL SURGERY; SURGICAL MANEUVERS; INTRAOPERATIVE OCT; OPHTHALMIC SURGERY; MOUNTED DISPLAY; INTEGRATED OCT; HAND-HELD; SIMULATOR; MEMBRANE;
D O I
10.1364/BOE.9.002825
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Virtual reality (VR) head-mounted displays are an attractive technology for viewing intrasurgical optical coherence tomography (OCT) volumes because they liberate surgeons from microscope oculars. We demonstrate real-time, interactive viewing of OCT volumes in a commercial HTC Vive immersive VR system using previously reported ray casting techniques. Furthermore, we show interactive manipulation and sectioning of volumes using handheld controllers and guidance of mock surgical procedures in porcine eyes exclusively within VR. To the best of our knowledge, we report the first immersive VR-OCT viewer with stereo ray casting volumetric renders, arbitrary sectioning planes, and live acquisition support. We believe VR-OCT volume displays will advance ophthalmic surgery towards VR-integrated surgery. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:2825 / 2843
页数:19
相关论文
共 44 条
[1]  
Aaker Grant D, 2011, Ophthalmic Surg Lasers Imaging, V42 Suppl, pS116, DOI 10.3928/15428877-20110627-11
[2]   FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY [J].
Binder, Susanne ;
Falkner-Radler, Christiane I. ;
Hauger, Christoph ;
Matz, Holger ;
Glittenberg, Carl .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (07) :1332-1336
[3]  
BUKATY E, 2015, INVEST OPHTHALMOL VI, V56
[4]   The Effect of Apparent Latency on Simulator Sickness While Using a See-Through Helmet-Mounted Display: Reducing Apparent Latency With Predictive Compensation [J].
Buker, Timothy J. ;
Vincenzi, Dennis A. ;
Deaton, John E. .
HUMAN FACTORS, 2012, 54 (02) :235-249
[5]  
Carl Zeiss Meditec, OPMI LUMERA 700 RESC
[6]   Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography [J].
Carrasco-Zevallos, O. M. ;
Keller, B. ;
Viehland, C. ;
Shen, L. ;
Waterman, G. ;
Todorich, B. ;
Shieh, C. ;
Hahn, P. ;
Farsiu, S. ;
Kuo, A. N. ;
Toth, C. A. ;
Izatt, J. A. .
SCIENTIFIC REPORTS, 2016, 6
[7]   Review of intraoperative optical coherence tomography: technology and applications [Invited] [J].
Carrasco-Zevallos, Oscar M. ;
Viehland, Christian ;
Keller, Brenton ;
Draelos, Mark ;
Kuo, Anthony N. ;
Toth, Cynthia A. ;
Izatt, Joseph A. .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03) :1607-1637
[8]   INTRAOPERATIVE USE OF HANDHELD SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING IN MACULAR SURGERY [J].
Dayani, Pouya N. ;
Maldonado, Ramiro ;
Farsiu, Sina ;
Toth, Cynthia A. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (10) :1457-1468
[9]  
Draelos M, 2017, IEEE INT C INT ROBOT, P2549, DOI 10.1109/IROS.2017.8206076
[10]  
Ehlers J. P., 2017, RETINA