A new fullerene-C60 - Nanogold composite for non-enzymatic glucose sensing

被引:43
作者
Sutradhar, Sanjeeb [1 ]
Patnaik, Archita [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Colloid & Interface Chem Lab, Madras 600036, Tamil Nadu, India
关键词
Functionalized fullerene C-60; Gold nanocomposite; DFT computation; Amperometry; Non-enzymatic glucose sensing; GLASSY-CARBON ELECTRODES; GOLD NANOPARTICLES; BIOMEDICAL APPLICATIONS; HYDROGEN-PEROXIDE; ACID DERIVATIVES; SENSOR; BIOSENSOR; FILM; ELECTROCHEMISTRY; C-60;
D O I
10.1016/j.snb.2016.10.111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new functionalized fullerene C-60 - thiol capped gold nanoparticle based nanocomposite using 3-amino5-mercapto-1,2,4-triazole as the ligand was designed and synthesized following electronic structure calculation via DFT formalism. The electrostatic potential map from the OFT optimized geometry implied C-60 core of the composite to remain electron deficient, and a much reduced HOMO-LUMO energy gap for the composite towards enhanced electron-transport ability was noted. Experimentally, first, fullerene-C-60 was functionalized with the multipolar group containing ligand 3-amino-5-mercapto-1,2,4-triazole, making it hydrophilic and its aqueous dispersion was subsequently used to make a composite with in-situ prepared aqueous phase gold nanoparticles. The composite modified glassy carbon electrode showed electrocatalytic behaviour towards sensing of glucose, studied via cyclic voltammetry and electrochemical impedance spectroscopy. Thus, the highly stable and low onset potential non-enzymatic sensor exhibited high electro-catalytic activity and effective electron transfer from the electro-catalyst to the substrate electrode in a linear concentration range spanning over 0.025-0.8 mM and a higher sensitivity response of 1.2 mu A mM(-1) cm(-2) with good reproducibility, long term stability, anti-interference ability and chloride poisoning resistance. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:681 / 689
页数:9
相关论文
共 55 条
[31]   Synthesis of gold nanoparticles in an interdigital micromixer using ascorbic acid and sodium borohydride as reducers [J].
Luty-Blocho, M. ;
Fitzner, K. ;
Hessel, V. ;
Loeb, P. ;
Maskos, M. ;
Metzke, D. ;
Paclawski, K. ;
Wojnicki, M. .
CHEMICAL ENGINEERING JOURNAL, 2011, 171 (01) :279-290
[32]   Electrochemical oxidation of glucose at Hg adatom-modified Au electrode in alkaline aqueous solution [J].
Matsumoto, F ;
Harada, M ;
Koura, N ;
Uesugi, S .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (01) :42-46
[33]   Reactions between aliphatic amines and [60]fullerene: a review [J].
Miller, GP .
COMPTES RENDUS CHIMIE, 2006, 9 (7-8) :952-959
[34]   Electrochemiluminescence biosensor for cholesterol detection based on AuNPs/L-cys-C60 nanocomposites [J].
Ou, Xin ;
Tan, Xingrong ;
Wei, Shaping ;
Chen, Shihong ;
Zhang, Juanjuan ;
Liu, Xiaofang .
ANALYTICAL METHODS, 2014, 6 (11) :3804-3810
[35]   Interaction of amino acids with gold and silver clusters [J].
Pakiari, A. H. ;
Jamshidi, Z. .
JOURNAL OF PHYSICAL CHEMISTRY A, 2007, 111 (20) :4391-4396
[36]   Electrochemical fabrication of gold nanoparticles decorated on activated fullerene C60: an enhanced sensing platform for trace level detection of toxic hydrazine in water samples [J].
Palanisamy, Selvakumar ;
Thirumalraj, Balamurugan ;
Chen, Shen-Ming .
RSC ADVANCES, 2015, 5 (115) :94591-94598
[37]   Hydrophilic [60]fullerene carboxylic acid derivatives retaining the original 60π electronic system [J].
Periya, VK ;
Koike, I ;
Kitamura, Y ;
Iwamatsu, SI ;
Murata, S .
TETRAHEDRON LETTERS, 2004, 45 (45) :8311-8313
[38]   Recent Advances in Electrochemical Biosensors Based on Fullerene-C-60 Nano-Structured Platforms [J].
Pilehvar, Sanaz ;
De Wael, Karolien .
BIOSENSORS-BASEL, 2015, 5 (04) :712-735
[39]   A Glucose Biosensor Based on Deposition of Glucose Oxidase onto Crystalline Gold Nanoparticle Modified Carbon Nanotube Electrode [J].
Rakhi, Raghavan Baby ;
Sethupathi, Kanikrishnan ;
Ramaprabhu, Sundara .
JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (10) :3190-3194
[40]   Development of sensitive amperometric hydrogen peroxide sensor using a CuNPs/MB/MWCNT-C60-Cs-IL nanocomposite modified glassy carbon electrode [J].
Roushani, Mahmoud ;
Bakyas, Kobra ;
Dizajdizi, Behruz Zare .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 64 :54-60