Simple and novel electrochemical sensor for the determination of tetracycline based on iron/zinc cations-exchanged montmorillonite catalyst

被引:89
作者
Gan, Tian [1 ]
Shi, Zhaoxia [1 ]
Sun, Junyong [1 ]
Liu, Yanming [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
关键词
Tetracycline; Electrochemical sensor; Iron; Zinc; Montmorillonite; CARBON NANOTUBE; K10; MONTMORILLONITE; ANTIBIOTIC-RESIDUES; AMPEROMETRIC SENSOR; CHROMATOGRAPHY; NANOPARTICLES; EXPRESSION; ELECTRODE; WATER; FATE;
D O I
10.1016/j.talanta.2014.01.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and novel electrochemical sensor for the determination of tetracycline (TC), a kind of antibiotic that may induce residue in the food chain, was developed by the modification of iron/zinc cation-exchanged montmorillonite (Fe/Zn-MMT) catalyst on glassy carbon electrode (GCE). The morphology and the structure of the Fe/Zn-MMT nanomaterial were characterized by scanning electron microscopy and X-ray diffraction, respectively. The results of electrochemical experiments demonstrated that the sensor exhibited excellent electrocatalytic activity to the oxidation of TC in the presence of sodium dodecyl sulfate. The sensor displayed a wide linear range from 0.30 to 52.0 mu M and a low detection limit of 0.10 mu M by using the derivative differential pulse voltammetry. Moreover, the electrochemical sensor was applied to the detection of TC in feedstuff and meat samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 34 条
[1]   Resistance to antibiotics: Are we in the post-antibiotic era? [J].
Alanis, AJ .
ARCHIVES OF MEDICAL RESEARCH, 2005, 36 (06) :697-705
[2]  
Bard A.J, 2002, Student Solutions Manual to accompany Electrochemical Methods: Fundamentals and Applicaitons, V2e
[3]   A sensitive amperometric sensor for hydrazine and hydrogen peroxide based on palladium nanoparticles/onion-like mesoporous carbon vesicle [J].
Bo, Xiangjie ;
Bai, Jing ;
Ju, Jian ;
Guo, Liping .
ANALYTICA CHIMICA ACTA, 2010, 675 (01) :29-35
[4]  
Calixto CMF, 2012, J BRAZIL CHEM SOC, V23, P938, DOI 10.1590/S0103-50532012000500020
[5]   Fate of antibacterial spiramycin in river waters [J].
Calza, P. ;
Marchisio, S. ;
Medana, C. ;
Baiocchi, C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (04) :1539-1550
[6]  
Chen GY, 2013, ACS SYM SER, V1138, P49
[7]   Bimetallic PtM (M = Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for H2O2 [J].
Chen, Kuan-Jung ;
Pillai, K. Chandrasekara ;
Rick, John ;
Pan, Chun-Jern ;
Wang, Shih-Han ;
Liu, Chung-Chiun ;
Hwang, Bing-Joe .
BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) :120-127
[8]   Tetracycline antibiotics: Mode of action, applications, molecular biology, and epidemiology of bacterial resistance [J].
Chopra, I ;
Roberts, M .
MICROBIOLOGY AND MOLECULAR BIOLOGY REVIEWS, 2001, 65 (02) :232-+
[9]   Disposable amperometric magneto-immunosensor for direct detection of tetracyclines antibiotics residues in milk [J].
Conzuelo, Felipe ;
Gamella, Maria ;
Campuzano, Susana ;
Julio Reviejo, A. ;
Pingarron, Jose M. .
ANALYTICA CHIMICA ACTA, 2012, 737 :29-36
[10]   Sensitivity improvement of the oxidation of tetracycline at acetylene black electrode in the presence of sodium dodecyl sulfate [J].
Dang, XP ;
Hu, CG ;
Wei, YL ;
Chen, WH ;
Hu, SS .
ELECTROANALYSIS, 2004, 16 (23) :1949-1955