On the importance of modelling organ geometry and boundary conditions for predicting three-dimensional prostate deformation

被引:10
作者
Jahya, Alex [1 ]
Schouten, Martijn G. [2 ]
Fuetterer, Jurgen J. [2 ]
Misra, Sarthak [1 ]
机构
[1] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiol, Med Ctr, NL-6525 ED Nijmegen, Netherlands
关键词
computer-assisted surgical simulation; finite element modelling; biopsy; needle insertion; magnetic resonance; ultrasound; REGISTRATION; ULTRASOUND; ELASTICITY;
D O I
10.1080/10255842.2012.694876
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The use of an ultrasound probe or a needle guide during biopsy deforms both the rectal wall and the prostate, resulting in lesion motion. An accurate patient-specific finite element (FE)-based biomechanical model can be used to predict prostate deformations. In this study, an FE model of a prostate phantom is developed using magnetic resonance images, while soft-tissue elasticity is estimated in vivo using an ultrasound-based acoustic radiation force impulse imaging technique. This study confirms that three-dimensional FE-predicted prostate deformation is predominantly dependent on accurate modelling of prostate geometry and boundary conditions. Upon application of various compressive displacements, our results show that a linear elastic FE model can accurately predict prostate deformations. The maximum global error between FE-predicted simulations and experimental results is 0.76mm. Moreover, the effect of including the urethra, puboprostatic ligament and urinary bladder on prostate deformations is investigated by a sensitivity study.
引用
收藏
页码:497 / 506
页数:10
相关论文
共 27 条
[21]  
Ottensmeyer MP, 2007, PERFUSION, V24, P219
[22]   Quantifying hepatic shear modulus in vivo using acoustic radiation force [J].
Palmeri, M. L. ;
Wang, M. H. ;
Dahl, J. J. ;
Frinkley, K. D. ;
Nightingale, K. R. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (04) :546-558
[23]  
Pezzernenti Z, 2008, SYMPOSIUM ON HAPTICS INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS 2008, PROCEEDINGS, P209
[24]  
Reddy J.N., 2005, An Introduction to the Finite Element Method
[25]  
Shariat Shahrokh F, 2008, Rev Urol, V10, P262
[26]  
Siemens Medical Solutions USA Inc, 2010, ACUSON S2000 DIAGN U
[27]   Clinical and physical determinants for toxicity of 125-I seed prostate brachytherapy [J].
Wust, P ;
von Borczyskowski, DW ;
Henkel, T ;
Rosner, C ;
Graf, R ;
Tilly, W ;
Budach, V ;
Felix, R ;
Kahmann, F .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (01) :39-48