Methylene blue potentiometric sensor for selective determination of sulfide ions

被引:56
作者
Hassan, SSM [1 ]
Marzouk, SAM
Sayour, HEM
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Anim Hlth Res Inst, Dept Chem & Nutrit Deficiency Dis, Clin Chem Unit, Giza, Egypt
关键词
methylene blue; potentiometric sensor; sulfide ions; Caro's reaction; wastewaters analysis; potentiometric titration;
D O I
10.1016/S0003-2670(02)00515-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new poly(vinyl chloride) (PVC) membrane sensor for methylene blue cation (MB+) is prepared, characterized and used for determination of sulfide ions. The sensor shows a cationic response slope of 56.2 +/- 0.3 mV per concentration decade and a linear response range of 6 x 10(-7) to 10(-4) Mol 1(-1) MB+ with a lower detection limit of 3.8 x 10(-7) Mol 1(-1) MB+ in Tris buffer of pH 8.7. The sensor is used for determination of sulfide ions after conversion into MB using Caro's reaction. Optimized reaction conditions result in a wide dynamic, linear response range (0.12-15 mug ml(-1) sulfide-sulfur), short reaction time (1-2 min), low detection limit (0.01 mug ml(-1) sulfide-sulfur), high accuracy (>98% recovery) and remarkable selectivity. The method displays significant advantages over many other techniques used for quantification of sulfide ions. Determination of sulfide ions in real samples of complex matrices, e.g. wastewaters gives results that compare fairly well with those obtained with the standard methods. The sensor is also used to monitor titration of some complex anions such as reineckate, hexanitrocobaltate(III), tetraphenylborate and tetraiodomercurate with MB as a titrant. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 31 条
[1]  
*AM PUBL HLTH ASS, 1985, STAND METH EX WAT WA, P740
[2]  
[Anonymous], 1939, Journal of the American Chemical Society, DOI [10.1021/ja01877a013, DOI 10.1021/JA01877A013]
[3]  
BAETZOLD RC, 1971, J AM CHEM SOC, V93, P1347
[4]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[5]   PHOTOMETRIC DETERMINATION OF SULFIDE AND REDUCIBLE SULFUR IN ALKALIES [J].
BUDD, MS ;
BEWICK, HA .
ANALYTICAL CHEMISTRY, 1952, 24 (10) :1536-1540
[6]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN SULFIDE - METHYLENE BLUE METHOD [J].
FOGO, JK ;
POPOWSKY, M .
ANALYTICAL CHEMISTRY, 1949, 21 (06) :732-734
[7]  
Gustafsson L., 1960, TALANTA, V4, P227
[8]   Ribonucleic acid as a novel ionophore for potentiometric membrane sensors of some transition metal ions [J].
Hassan, SSM ;
Mahmoud, WH ;
Othman, AHM .
TALANTA, 1998, 47 (02) :377-385
[9]   A NOVEL FERROIN MEMBRANE SENSOR FOR POTENTIOMETRIC DETERMINATION OF IRON [J].
HASSAN, SSM ;
MARZOUK, SAM .
TALANTA, 1994, 41 (06) :891-899
[10]  
Hofmeister F., 1888, ARCH F R EXP PATHOL, V24, P247, DOI DOI 10.1007/BF01918191