摘要
A sensitive LC-ESI-MS/MS method for simultaneous determination of MTC-220 and its metabolites (paclitaxel and MDA-linker) in dog plasma has been developed and validated. After addition of docetaxel (internal standard), plasma samples containing MTC-220, paclitaxel and MDA-linker were prepared based on a simple protein precipitation by adding two volumes of acetonitrile. The separation was performed on a ZorbaxSB-C18 column (3.5 mu m, 2.1 mm x 100 mm) at a flow rate of 0.2 ml/min, using acetonitrile/water containing 0.1% formic acid (v/v) as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) by selected reaction monitoring (SRM). The MS/MS ion transit ions monitored were 1444.4 -> 623.8 for MTC-220, 876.4 -> 307.9 for paclitaxel, 631.2 -> 531.2 for MDA-linker and 830.2 -> 549.1 for the internal standard. Linear detection responses were obtained for MTC-220, paclitaxel and MDA-linker ranging from 10 to 5000, 5 to 2500 and 5 to 500 ng/ml, respectively. The lower limits of quantitation (LLOQs) for MTC-220, paclitaxel and MDA-linker were 10, 5 and 5 ng/ml, respectively. The intra-day and inter-day precisions (RSD, %) of the three analytes do not exceed 10.9% except for LLOQs (<= 17.50), and the accuracy (RE, %) were within +/- 17.5% for LLOQs and +/- 12.6% for the others. The average recoveries of three compounds were greater than 85.0%. The analytes were proved to be stable during all sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic studies of MTC-220 and its metabolites in beagle dogs after intravenous infusion of MTC-220 at 2.5 mg/kg.. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
[41]   A validated method for the quantification of fosfomycin in human plasma by liquid chromatography-tandem mass spectrometry [J].
Martens-Lobenhoffer, Jens ;
Bode-Boeger, Stefanie M. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 :164-168
[42]   Simultaneous Determination of Artemether and Its Major Metabolites Dihydroartimisinin in Rat Plasma Using Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Li Chun ;
Qiu Yu-Qin ;
Yang Guo-Zhong ;
Meng Fan-Da ;
Zhang Suo-Hui ;
Gao Yun-Hua .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (04) :560-565
[43]   Simultaneous quantification of curdione, furanodiene and germacrone in rabbit plasma using liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study [J].
Wang, Baolian ;
Yang, Shuang ;
Sheng, Li ;
Li, Yan .
BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (09) :1393-1398
[44]   Simultaneous quantification and confirmation of oxycodone and its metabolites in equine urine using ultra-high performance liquid chromatography-tandem mass spectrometry [J].
You, Youwen ;
Missanelli, Jaclyn R. ;
Proctor, Rachel M. ;
Haughan, Joanne ;
Robinson, Mary A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1238
[45]   Simultaneous Determination of Flavonols and Terpene Lactones in Beagle Dog Plasma by Ultra-Performance Liquid Chromatography-Tandem - Mass Spectrometry: 1. Method Development [J].
Lu, Yang ;
Li, Pengyue ;
Liu, Huimin ;
Du, Shouying ;
Cheng, Yanke ;
Wu, Huichao ;
Feng, Jiannan ;
Shao, Beibei .
TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (05) :869-878
[46]   Simultaneous quantitation of hydrochlorothiazide and metoprolol in human plasma by liquid chromatography-tandem mass spectrometry [J].
Gao, Feng ;
Zhang, Mengliang ;
Cui, Xiangyong ;
Wang, Zhonghua ;
Sun, Yantong ;
Gu, Jingkai .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (01) :149-154
[47]   Determination of larotaxel and its metabolites in rat plasma by liquid chromatography-tandem mass spectrometry: Application for a pharmacokinetic study [J].
Liu, Zhenzhen ;
Zhang, Lunhui ;
Ju, Ping ;
Hou, Pengyi ;
Zhang, Yuanyuan ;
Tang, Xing ;
Bi, Kaishun ;
Chen, Xiaohui .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 :132-138
[48]   Validated liquid chromatography-tandem mass spectrometry method for quantification of ticagrelor and its active metabolite in human plasma [J].
Xu, Xiaomin ;
Ding, Xiaohong ;
Yuan, Bo ;
Li, Weiwei ;
Wang, Yimei ;
Jin, Yi ;
Xu, Haiyan .
BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (06)
[49]   Simultaneous quantification of dabrafenib and trametinib in human plasma using high-performance liquid chromatography-tandem mass spectrometry [J].
Nijenhuis, C. M. ;
Haverkate, H. ;
Rosing, H. ;
Schellens, J. H. M. ;
Beijnen, J. H. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 125 :270-279
[50]   Quantification of polygalasaponin F in rat plasma using liquid chromatography-tandem mass spectrometry and its pharmacokinetics application [J].
Zhou, Wenli ;
Zhang, Jiantao ;
Xu, Wei ;
Sun, Jinghui .
BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (09) :1388-1392