HIGH RESOLUTION WRIST MR ARTHROGRAPHY AT 1.5 T

被引:0
作者
van Dijke, C. F. [1 ]
Wiarda, B. M. [1 ]
机构
[1] Med Cent Alkmaar, Dept Radiol, NL-1815 JD Alkmaar, Netherlands
来源
JBR-BTR | 2009年 / 92卷 / 01期
关键词
Wrist; arthrography; MR; TRIANGULAR FIBROCARTILAGE COMPLEX; IODINATED CONTRAST MATERIAL; ASYMPTOMATIC WRISTS; NORMAL APPEARANCE; DEFECTS; LESIONS; GADOLINIUM; INJECTION; LIGAMENTS; SHOULDER;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR arthrography of the wrist is a valuable tool for the diagnosis and evaluation of a wide spectrum of acute and chronic articular disorders. The method has the potential of replacing diagnostic arthroscopy for the evaluation of the triangular fibrocartilage complex and the intrinsic and extrinsic ligaments. High resolution MR imaging with a dedicated coil is essential for detecting partial thickness tears. Abnormalities, such as leakage of injected contrast agent from one compartment into another are common in asymptomatic subjects. An optimal communication concerning clinical symptoms between the radiologist and referring clinician is essential not to overreport abnormalities without clinical importance. Awareness of normal variants and pitfalls is essential. Combining iodinated and gadolinium based contrast agents for MR arthrography may have additional value.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 21 条
[1]   Direct MR arthrography at 1.5 and 3.0 T: Signal dependence on gadolinium and iodine concentrations - Phantom study [J].
Andreisek, Gustav ;
Froehlich, Johannes M. ;
Hodler, Juerg ;
Weishaupt, Dominik ;
Beutler, Verena ;
Pfirrmann, Christian W. A. ;
Boesch, Chris ;
Nanz, Daniel .
RADIOLOGY, 2008, 247 (03) :706-716
[2]   MR arthrography of the shoulder, hip, and wrist: Evaluation of contrast dynamics and image quality with increasing injection-to-imaging time [J].
Andreisek, Gustav ;
Duc, Sylvain R. ;
Froehlich, Johannes M. ;
Hodler, Juerg ;
Weishaupt, Dominik .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) :1081-1088
[3]   Direct MR arthrography of the wrist-value in detecting complete and partial defects of intrinsic ligaments and the TFCC in comparison with arthroscopy [J].
Braun, H ;
Kenn, W ;
Schneider, S ;
Graf, M ;
Sandstede, J ;
Hahn, D .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (11) :1515-1524
[4]   Is a mixture of gadolinium and iodinated contract material safe during MR arthrography? [J].
Brown, RR ;
Clarke, DW ;
Daffner, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :1087-1090
[5]   Wrist MR arthrography:: How, why, when [J].
Cerezal, L ;
Abascal, F ;
Garcia-Valtuille, R ;
del Piñal, F .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (04) :709-+
[6]   Technical considerations for injection of a mixture of iodinated contrast material and Artirem® for combined CT and MR arthrography [J].
Detreille, R. ;
Sauer, B. ;
Zabel, J. P. ;
Batch, T. ;
Zhu, X. ;
Blum, A. .
JOURNAL DE RADIOLOGIE, 2007, 88 (06) :863-869
[7]  
Garcia-Elias M, 1998, HAND CLIN, V14, P165
[8]   MR ARTHROGRAPHY OF THE SHOULDER WITH GADOPENTETATE DIMEGLUMINE - INFLUENCE OF CONCENTRATION, IODINATED CONTRAST MATERIAL, AND TIME ON SIGNAL INTENSITY [J].
KOPKA, L ;
FUNKE, M ;
FISCHER, U ;
KEATING, D ;
OESTMANN, J ;
GRABBE, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :621-623
[9]   Scapholunate ligamentous communicating defects in symptomatic and asymptomatic wrists: Characteristics [J].
Linkous, MD ;
Pierce, SD ;
Gilula, LA .
RADIOLOGY, 2000, 216 (03) :846-850
[10]   Optimization of gadodiamide concentration for MR arthrography at 3 T [J].
Masi, JN ;
Newitt, D ;
Sell, CA ;
Daldrup-Link, H ;
Steinbach, L ;
Majumdar, S ;
Link, TM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) :1754-1761