PRE-TENSIONED STEEL CABLES EXPOSED TO LOCALISED FIRES

被引:7
作者
Du, Yong [1 ,2 ,3 ]
Liew, J. Y. Richard [1 ,3 ]
Zhang, Hao [1 ]
Guoqiang-Li [2 ]
机构
[1] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211800, Jiangsu, Peoples R China
[2] Civil Engn Disaster Prevent Natl Key Lab, Shanghai 200092, Peoples R China
[3] Natl Univ Singapore, Dept Civil & Environm Engn, Singapore 117576, Singapore
来源
ADVANCED STEEL CONSTRUCTION | 2018年 / 14卷 / 02期
关键词
Cable-tensioned structure; fire resistance; localised fire; pre-tensioned structure; steel cable;
D O I
10.18057/IJASC.2018.14.2.5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Pre-tensioned steel cables are often used in hybrid string structures, suspended roofs and cable suspended bridges. When subjected to localised fire, the tensile force in the steel cables reduces due to thermal expansion, and thus, the geometry of the structure and the internal force distribution in the cable-tensioned structure will be affected. The mechanical behavior of pre-tensioned steel cables is sensitive to the elevated temperature history. In this paper, a set of analytical formulation has been proposed to determine the transient tension force in a cable subjected to localised heating considenng the mechanical properties at elevated temperature and the effects of loading configuration, pre-tensioned force level, and thermal expansion at elevated temperature. The fire resistance of a pre-tensioned steel cable can be determined when the cable tension force is equal to its effective yield strength at elevated temperature. Meanwhile, the proposed method is able to capture the relationship between the transient tension forces with each influence parameter in order to study the behavior of steel cables subjected to localised fire. The mechanical responses predicted by the proposed analytical method of pre-tensioned cables exposed to localised fires are validated against the numerical results obtained from nonlinear finite element software. Finally, a design flow chart is proposed for fire resistant design of pre-tensioned steel cables and the calculations can be implemented using a spreadsheet program.
引用
收藏
页码:206 / 226
页数:21
相关论文
共 14 条
[1]  
[Anonymous], 1992, 199112 EN EUR COMM S
[2]  
[Anonymous], 2005, 140905 ASTM INT
[3]  
Du Y., 2009, INT C APPL STRUCT FI, P356
[4]   A new temperature-time curve for fire-resistance analysis of structures [J].
Du, Yong ;
Li, Guo-qiang .
FIRE SAFETY JOURNAL, 2012, 54 :113-120
[5]  
Fan D, 2015, THESIS
[6]  
Krishna P., 1978, CABLE SUSPENSION ROO
[7]  
National Institute of Standards for Engineering, 2006, CECS, V200
[8]  
NFPA, 2006, 251 NFPA
[9]   The role of string in hybrid string structure [J].
Saitoh, M ;
Okada, A .
ENGINEERING STRUCTURES, 1999, 21 (08) :756-769
[10]  
Shen S., 2006, Design of Cable Structures