Energy-Resolving Photon-Counting Detectors in CT Based Explosive Detection Systems (EDS)

被引:0
|
作者
Skatter, Sondre [1 ]
Olesinski, Stephan [2 ]
机构
[1] Morpho Detect LLC, Newark, CA USA
[2] Morpho Detect Germany GmbH, Hamburg, Germany
来源
2014 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY (ICCST) | 2014年
关键词
X-rays; dual energy; material discrimination; photon counting detectors; TOMOGRAPHY;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We evaluated a data set consisting of 38 different materials - threats and non-threats - to determine whether there are signatures detectable in CT systems equipped with energyresolving photon-counting detectors that would help the detection task. Data with such detectors was collected in a lab setup using a Compton spectrometer and simple transmission measurements through samples of known material and thickness. Two alternative decomposition methods, SVD and NNMF, were evaluated and found to produce equivalent model predictions as a physics-based model. Furthermore, all three methods performed equally well with respect to material discrimination, which was evaluated by Kullback-Leibler divergence. No additional material signatures, beyond electron density and effective atomic number, appeared to be extractable from the attenuation spectra.
引用
收藏
页数:6
相关论文
共 32 条
  • [21] Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT
    El-Ali, Alexander M.
    Strubel, Naomi
    Pinkney, Lynne
    Xue, Christine
    Dane, Bari
    Lala, Shailee V.
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1984 - 1995
  • [22] A multi-wavelength, single-pixel SFD imaging system based on lock-in photon-counting detection
    Hou, Xi
    Li, Tongxin
    Zhao, Kuanxin
    Dan, Mai
    Gao, Feng
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XIII, 2019, 10874
  • [23] Assessment of multi-energy inter-pixel coincidence counters for photon-counting detectors at the presence of charge sharing and pulse pileup: A simulation study
    Taguchi, Katsuyuki
    Iwanczyk, Jan S.
    MEDICAL PHYSICS, 2021, 48 (09) : 4909 - 4925
  • [24] An investigation into the temporal stability of CdTe-based photon counting detectors during spectral micro-CT acquisitions
    Zuber, Marcus
    Hamann, Elias
    Ballabriga, Rafael
    Campbell, Michael
    Fiederle, Michael
    Baumbach, Tilo
    Koenig, Thomas
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (02):
  • [25] A method based on wavelet transforms for source detection in photon-counting detector images .2. Application to ROSAT PSPC images
    Damiani, F
    Maggio, A
    Micela, G
    Sciortino, S
    ASTROPHYSICAL JOURNAL, 1997, 483 (01) : 370 - 389
  • [26] Photon-counting detector CT-based virtual monoenergetic reconstructions: repeatability and reproducibility of radiomics features of an organic phantom and human myocardium
    Wolf, Elias V.
    Mueller, Lukas
    Schoepf, U. Joseph
    Fink, Nicola
    Griffith, Joseph P.
    Zsarnoczay, Emese
    Baruah, Dhiraj
    Suranyi, Pal
    Kabakus, Ismael M.
    Halfmann, Moritz C.
    Emrich, Tilman
    Varga-Szemes, Akos
    O'Doherty, Jim
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [27] Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
    Booij, Ronald
    van der Werf, Niels R.
    Dijkshoorn, Marcel L.
    van der Lugt, Aad
    van Straten, Marcel
    DIAGNOSTICS, 2022, 12 (06)
  • [28] Determination of Optimal Image Type and Lowest Detectable Concentration for Iodine Detection on a Photon Counting Detector Based Multi-Energy CT System
    Zhou, Wei
    Schornak, Rachel
    Michalak, Gregory
    Weaver, Jayse
    Abdurakhimova, Dilbar
    Ferrero, Andrea
    Fetterly, Kenneth A.
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [29] Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT
    Stephan Rau
    Alexander Rau
    Thomas Stein
    Muhammad Taha Hagar
    Sebastian Faby
    Fabian Bamberg
    Jakob Weiss
    La radiologia medica, 2024, 129 : 669 - 676
  • [30] Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT
    Rau, Stephan
    Rau, Alexander
    Stein, Thomas
    Hagar, Muhammad Taha
    Faby, Sebastian
    Bamberg, Fabian
    Weiss, Jakob
    RADIOLOGIA MEDICA, 2024, 129 (04): : 585 - 597