Development of Ammonium-Selective Electrode Based on PVC/MB28 Membrane

被引:3
作者
Alva, Sagir [1 ]
Sundari, R. [1 ]
Aziz, A. S. A. [2 ]
Rashid, N. A. A. [2 ]
Gunawan, W. [3 ]
机构
[1] Mercubuana Univ, Mech Engn, South Meruya 1 Kembangan West, Jakarta 11650, Indonesia
[2] MIMOS Berhad, Photon R&D NST Dept, Technol Pk Malaysia, Kuala Lumpur 57000, Malaysia
[3] Univ Teknol PETRONAS, Elect & Elect Engn Dept, Fac Engn, Seri Iskandar 32610, Perak Darul Rid, Malaysia
来源
INTERNATIONAL CONFERENCE ON DESIGN, ENGINEERING AND COMPUTER SCIENCES | 2018年 / 453卷
关键词
PVC; MB28; ISE-NH4+; PVC/MB28; membrane; ammonium ion;
D O I
10.1088/1757-899X/453/1/012042
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In this study, the ISE-NH4+ sensor based on hybrid membrane of the poly (vinyl chloride)/methyl methacrylate-butyl acrylate 2: 8 co-polymer (PVC/MB28) has been successfully developed, where the ratio between PVC: MB28 is 9:1. Meanwhile, the plasticized material used is dioctyl sebacate (DOS) of 66.34 wt. %, the amount of lipophilic salt of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) used is 0.99 wt. %, and nonactine as much as 2.97 wt.%. The addition of the MB28 co-polymer has successfully improved the performance and mechanical strength of ISE-NH4+ especially at measurements at 40 degrees C. The ISE-NH4+ sensor based on PVC/MB28 has a Nernstian number of 55.4 and 58.7 mV/dec for measurement at 25oC and 40oC with the linear range between 0.1 - 10(-5) M. While the ISE-NH4+ sensors based on PVC used as benchmarking have Nernstian numbers of 54.2 and 35.3 mV/dec for measurements at 25 degrees C and 40 degrees C, where the linear range is 0.1 - 10(-5) M and 0.1 - 10(-3) M. The addition of MB28 also does not cause the selectivity of the ISE-NH4+ sensor to decrease, where the result of the selectivity between PVC/MB28 is comparable to PVC.
引用
收藏
页数:5
相关论文
共 12 条
[1]  
Alva S., 2017, J PHYS SCI, V28, P161, DOI [10.21315/jps2017.28.2.11, DOI 10.21315/JPS2017.28.2.11]
[2]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[3]  
Claude G., 2004, J ELECTROANAL CHEM, V570, P275
[4]   Ammonium ion sensor based on photocured and self-plasticising acrylic films for the analysis of sewage [J].
Heng, LY ;
Alva, S ;
Ahmad, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (2-3) :160-165
[5]   Methacrylic-acrylic polymers in ion-selective membranes: achieving the right polymer recipe [J].
Heng, LY ;
Hall, EAH .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :77-89
[6]   Bilayer membranes for ion-selective electrodes [J].
Kisiel, Anna ;
Michalska, Agata ;
Maksymiuk, Krzysztof .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 :128-134
[7]   Ion-Selective Electrodes with Unusual Response Functions: Simultaneous Formation of Ionophore-Primary Ion Complexes with Different Stoichiometries [J].
Miyake, Masafumi ;
Chen, Li D. ;
Pozzi, Gianluca ;
Buehlmann, Philippe .
ANALYTICAL CHEMISTRY, 2012, 84 (02) :1104-1111
[8]  
Nurato S. A., 2016, IJASEAT, P37
[9]   A conductive polypyrrole based ammonium ion selective electrode [J].
Quan, DP ;
Quang, CX ;
Duan, LT ;
Viet, PH .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2001, 70 (1-2) :153-165
[10]   Screening highly selective ionophores for heavy metal ion-selective electrodes and potentiometric sensors [J].
Sun, Lingzhi ;
Sun, Chengjun ;
Sun, Xianxiang .
ELECTROCHIMICA ACTA, 2016, 220 :690-698