Global tidal variations, regional distribution of ventilation, and the regional onset of filling determined by electrical impedance tomography: reproducibility

被引:3
作者
Caruana, L. R. [1 ]
Barnett, A. G. [2 ,3 ]
Tronstad, O. [4 ]
Paratz, J. D. [5 ,6 ]
Chang, A. T. [7 ]
Fraser, J. F. [8 ]
机构
[1] Univ Queensland, Prince Charles Hosp, Sch Med, Crit Care Res Grp, Brisbane, Qld, Australia
[2] Queensland Univ Technol, Prince Charles Hosp, Sch Publ Hlth, Crit Care Res Grp, Brisbane, Qld, Australia
[3] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld, Australia
[4] Prince Charles Hosp, Crit Care Res Grp, Brisbane, Qld, Australia
[5] Univ Queensland, Prince Charles Hosp, Burns Trauma & Crit Res Ctr, Sch Med,Critical Care Res Grp, Brisbane, Qld, Australia
[6] Griffith Univ, Southport, Qld, Australia
[7] Univ Queensland, Prince Charles Hosp, Sch Hlth & Rehabil Sci, Crit Care Res Grp, Brisbane, Qld, Australia
[8] Univ Queensland, Prince Charles Hosp, Sch Hlth & Rehabil Sci, Crit Care Res Grp, Brisbane, Qld, Australia
关键词
electrical impedance tomography; regional distribution of ventilation; reproducibility; repeatability; tidal variation; EXPIRATORY LUNG-VOLUME; PULSE OXIMETRY; COMPUTED-TOMOGRAPHY; PORCINE MODEL; RECRUITMENT; INJURY; AGREEMENT; SURGERY; PEEP; AIR;
D O I
10.1177/0310057X1704500214
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The reproducibility of the regional distribution of ventilation and the timing of onset of regional filling as measured by electrical impedance tomography lacks evidence. This study investigated whether electrical impedance tomography measurements in healthy males were reproducible when electrodes were replaced between measurements. Part 1: Recordings of five volunteers lying supine were made using electrical impedance tomography and a pneumotachometer. Measurements were repeated at least three hours later. Skin marking ensured accurate replacement of electrodes. No stabilisation period was allowed. Part 2: Electrical impedance tomography recordings of ten volunteers; a 15 minute stabilisation period, extra skin markings, and time-averaging were incorporated to improve the reproducibility. Reproducibility was determined using the Bland-Altman method. To judge the transferability of the limits of agreement, a Pearson correlation was used for electrical impedance tomography tidal variation and tidal volume. Tidal variation was judged to be reproducible due to the significant correlation between tidal variation and tidal volume (r(2) = 0.93). The ventilation distribution was not reproducible. A stabilisation period, extra skin markings and time-averaging did not improve the outcome. The timing of regional onset of filling was reproducible and could prove clinically valuable. The reproducibility of the tidal variation indicates that non-reproducibility of the ventilation distribution was probably a biological difference and not measurement error. Other causes of variability such as electrode placement variability or lack of stabilisation when accounted for did not improve the reproducibility of the ventilation distribution.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 38 条
  • [1] Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    Adler, A
    Amyot, R
    Guardo, R
    Bates, JHT
    Berthiaume, Y
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) : 1762 - 1767
  • [2] Maximizing the Laboratory Setting for Testing Devices and Understanding Statistical Output in Pulse Oximetry
    Batchelder, Paul B.
    Raley, Dena M.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 : S85 - S94
  • [3] Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels
    Bikker, Ido G.
    Leonhardt, Steffen
    Bakker, Jan
    Gommers, Diederik
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (08) : 1362 - 1367
  • [4] Agreement between methods of measurement with multiple observations per individual
    Bland, J. Martin
    Altman, Douglas G.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) : 571 - 582
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] APPLIED POTENTIAL TOMOGRAPHY - POSSIBLE CLINICAL-APPLICATIONS
    BROWN, BH
    BARBER, DC
    SEAGAR, AD
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1985, 6 (02): : 109 - 121
  • [7] How to monitor lung recruitment in patients with acute lung injury
    Caironi, Pietro
    Gattinoni, Luciano
    [J]. CURRENT OPINION IN CRITICAL CARE, 2007, 13 (03) : 338 - 343
  • [8] Electrical impedance tomography: looking behind the secrets of regional lung function
    Calzia, E
    Hahn, G
    Hellige, G
    [J]. INTENSIVE CARE MEDICINE, 2005, 31 (11) : 1474 - 1475
  • [9] The time taken for the regional distribution of ventilation to stabilise: an investigation using electrical impedance tomography
    Caruana, L. R.
    Paratz, J. D.
    Chang, A.
    Barnett, A. G.
    Fraser, J. F.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (01) : 88 - 91
  • [10] Electrical impedance tomography in the clinical assessment of lung volumes following recruitment manoeuvres
    Caruana, Lawrence
    Paratz, Jennifer
    Chang, Angela
    Fraser, John
    [J]. PHYSICAL THERAPY REVIEWS, 2011, 16 (01) : 66 - 74