Preliminary Findings of Feasibility of a Wearable Soft-robotic Glove Supporting Impaired Hand Function in Daily Life A Soft-robotic Glove Supporting ADL of Elderly People

被引:5
作者
Radder, B. [1 ]
Prange-Lasonder, G. B. [1 ,2 ]
Kottink, A. I. R. [1 ,3 ]
Gaasbeek, L. [4 ]
Holmberg, J. [5 ]
Meyer, T. [6 ]
Buurke, J. H. [1 ,3 ]
Rietman, J. S. [1 ,2 ]
机构
[1] Roessingh Res & Dev, Roessingsbleekweg 33b, Enschede, Netherlands
[2] Univ Twente, Dept Biomech Engn, Enschede, Netherlands
[3] Univ Twente, Dept Biosyst & Signals, Enschede, Netherlands
[4] Natl Fdn Elderly, Regulierenring 2D, Bunnik, Netherlands
[5] Eskilstuna Kommun Vard Och Omsorgsforvaltningen, Eleonoragatan 18, Eskilstuna, Sweden
[6] TerzStiftung, Seestr 112, Berlingen, Switzerland
来源
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES FOR AGEING WELL AND E-HEALTH (ICT4AWE) | 2016年
关键词
Assistive Technology; Assistive Device; Hand; Activities of Daily Living; ASSISTANCE; ADULT;
D O I
10.5220/0005879001800185
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Elderly people frequently encounter difficulties in independently performing activities of daily living (ADL) due to a reduced hand function. Robotic assistive devices have the potential to provide the assistance that is necessary to perform ADL independently without the need of personal assistance. Therefore, the objective of the present study was to explore feasibility of a wearable soft-robotic glove (ironHand (iH) system) that can support hand function of elderly people in daily life. Thirty elderly people (>56 years) with a reduced hand function resulting in difficulties in performing ADL were recruited to perform six functional tasks three times with and without the iH system. Evaluation measurements consisted of functional tasks performance times and user-acceptance of the iH system, measured by the System Usability Scale (SUS). Participants improved their functional task performance after multiple attempts either with and without the glove, but performed significantly faster without the glove (p <= 0.032). Besides, the mean of the SUS score for the iH system was 70.1%. Although this indicates a good probability for acceptance in the field, several design adaptations are necessary to have a user-friendly and accepted assistive device.
引用
收藏
页码:180 / 185
页数:6
相关论文
共 20 条
  • [1] Functional and usability assessment of a robotic exoskeleton arm to support activities of daily life
    Ambrosini, Emilia
    Ferrante, Simona
    Rossini, Mauro
    Molteni, Franco
    Gfoehler, Margit
    Reichenfelser, Werner
    Duschau-Wicke, Alexander
    Ferrigno, Giancarlo
    Pedrocchi, Alessandra
    [J]. ROBOTICA, 2014, 32 (08) : 1213 - 1224
  • [2] Robot-assisted rehabilitation of hand function
    Balasubramanian, Sivakumar
    Klein, Julius
    Burdet, Etienne
    [J]. CURRENT OPINION IN NEUROLOGY, 2010, 23 (06) : 661 - 670
  • [3] An empirical evaluation of the System Usability Scale
    Bangor, Aaron
    Kortum, Philip T.
    Miller, James T.
    [J]. INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2008, 24 (06) : 574 - 594
  • [4] Brooke J., 1996, USABILITY EVALUATION, P189
  • [5] The aging hand
    Carmeli, E
    Patish, H
    Coleman, R
    [J]. JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2003, 58 (02): : 146 - 152
  • [6] Assistive technologies after stroke: self-management or fending for yourself? A focus group study
    Demain, Sara
    Burridge, Jane
    Ellis-Hill, Caroline
    Hughes, Ann-Marie
    Yardley, Lucy
    Tedesco-Triccas, Lisa
    Swain, Ian
    [J]. BMC HEALTH SERVICES RESEARCH, 2013, 13
  • [7] Frappier J., 2011, CLINICOECONOMIC STUD
  • [8] CHANGES IN HAND FUNCTION IN THE AGING ADULT AS DETERMINED BY THE JEBSEN TEST OF HAND FUNCTION
    HACKEL, ME
    WOLFE, GA
    BANG, SM
    CANFIELD, JS
    [J]. PHYSICAL THERAPY, 1992, 72 (05): : 373 - 377
  • [9] Does assistive technology substitute for personal assistance among the disabled elderly?
    Hoenig, H
    Taylor, DH
    Sloan, FA
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH, 2003, 93 (02) : 330 - 337
  • [10] Kinoshita H, 1996, EUR J APPL PHYSIOL, V74, P450