Influence of Thread Pitch, Helix Angle, and Compactness on Micromotion of Immediately Loaded Implants in Three Types of Bone Quality: A Three-Dimensional Finite Element Analysis

被引:24
作者
Ma, Pan [1 ,2 ]
Xiong, Wei [3 ]
Tan, Baosheng [1 ]
Geng, Wei [1 ]
Liu, Jiaqiang [4 ]
Li, Weihong [5 ]
Li, Dehua [2 ]
机构
[1] Capital Med Univ, Beijing Stomatol Hosp, Dept Oral Implantol, Beijing 100050, Peoples R China
[2] Fourth Mil Med Univ, State Key Lab Mil Stomatol, Sch Stomatol, Dept Oral Implantol, Xian 710032, Shanxi, Peoples R China
[3] Air Force Gen Hosp, Clin Aviat Med Ctr PLA, Beijing 100142, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Med, Peoples Hosp 9, Dept Oral & Craniomaxillofacial, Shanghai 200011, Peoples R China
[5] Capital Med Univ, Sch Basic Med Sci, Beijing 100069, Peoples R China
关键词
RESONANCE-FREQUENCY-ANALYSIS; PRIMARY STABILITY; IN-VIVO; VISCOELASTIC PROPERTIES; STRESS-DISTRIBUTION; OCCLUSAL FORCES; RELAXATION; OSSEOINTEGRATION; INTERFACE; DIAMETERS;
D O I
10.1155/2014/983103
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study investigated the influence of thread pitch, helix angle, and compactness on micromotion in immediately loaded implants in bone of varying density (D2, D3, and D4). Five models of the three-dimensional finite element (0.8 mm pitch, 1.6 mm pitch, 2.4 mm pitch, double-threaded, and triple-threaded implants) in three types of bone were created using Pro/E, Hypermesh, and ABAQUS software. The study had three groups: Group 1, different pitches (Pitch Group); Group 2, same compactness but different helix angles (Angle Group); and Group 3, same helix angle but different compactness (Compact Group). Implant micromotion was assessed as the comprehensive relative displacement. We found that vertical relative displacement was affected by thread pitch, helix angle, and compactness. Under vertical loading, displacement was positively correlated with thread pitch and helix angle but negatively with compactness. Under horizontal loading in D2, the influence of pitch, helix angle, and compactness on implant stability was limited; however, in D3 and D4, the influence of pitch, helix angle, and compactness on implant stability is increased. The additional evidence was provided that trabecular bone density has less effect on implant micromotion than cortical bone thickness. Bone type amplifies the influence of thread pattern on displacement.
引用
收藏
页数:13
相关论文
共 57 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   Implant design and intraosseous stability of immediately placed implants: a human cadaver study [J].
Akkocaoglu, M ;
Uysal, S ;
Tekdemir, I ;
Akca, K ;
Cehreli, MC .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) :202-209
[3]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[4]   Immediate and early implant loading protocols: A literature review of clinical studies [J].
Attard, NJ ;
Zarb, GA .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (03) :242-258
[5]   Immediate implant loading: Current status from available literature [J].
Avila, Gustavo ;
Galindo, Pablo ;
Rios, Hector ;
Wang, Hom-Lay .
IMPLANT DENTISTRY, 2007, 16 (03) :235-242
[6]  
Barewal RM, 2003, INT J ORAL MAX IMPL, V18, P641
[7]   The effects of preoperative resorption and jaw anatomy on implant success. A report of 303 cases [J].
Bass, S. L. ;
Triplett, R. G. .
CLINICAL ORAL IMPLANTS RESEARCH, 1991, 2 (04) :193-198
[8]  
Benzing U R, 1995, Int J Oral Maxillofac Implants, V10, P188
[9]   Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance-frequency analysis study with sandblasted-and-etched ITI implants [J].
Bischof, M ;
Nedir, R ;
Szmukler-Moncler, S ;
Bernard, JP ;
Samson, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) :529-539
[10]  
López AB, 2008, MED ORAL PATOL ORAL, V13, pE244