Dose calculation and treatment plan optimization including imaging dose from kilovoltage cone beam computed tomography

被引:22
作者
Alaei, Parham [1 ]
Spezi, Emiliano [2 ]
Reynolds, Margaret [1 ]
机构
[1] Univ Minnesota, Dept Radiat Oncol, Minneapolis, MN 55455 USA
[2] Velindre Canc Ctr, Dept Med Phys, Cardiff, S Glam, Wales
关键词
PEDIATRIC CANCER-PATIENTS; MONTE-CARLO-SIMULATION; RADIATION-THERAPY; GUIDED RADIOTHERAPY; PATIENT DOSIMETRY; CT; SYSTEM; QUALITY; IMRT; CBCT;
D O I
10.3109/0284186X.2013.875626
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. With the increasing use of cone beam computed tomography (CBCT) for patient position verification and radiotherapy treatment adaptation, there is an increasing need to develop techniques that can take into account concomitant dose using a personalized approach. Material and methods. A total of 20 patients (10 pelvis and 10 head and neck) who had undergone radiation therapy using intensity modulated radiation therapy (IMRT) were selected and the dose from kV CBCT was retrospectively calculated using a treatment planning system previously commissioned for this purpose. The imaging dose was added to the CT images used for treatment planning and the difference in its addition prior to and after the planning was assessed. Results. The additional isocenter dose as a result of daily CBCT is in the order of 3-4 cGy for 35-fraction head and neck and 23-47 cGy for 25-fraction pelvis cases using the standard head and neck and pelvis image acquisition protocols. The pelvic dose is especially dependent on patient size and body mass index (BMI), being higher for patients with lower BMI. Due to the low energy of the kV CBCT beam, the maximum energy deposition is at or near the surface with the highest dose being on the patient's left side for the head and neck (similar to 7 cGy) and on the posterior for the pelvic cases (similar to 80 cGy). Addition of imaging dose prior to plan optimization resulted in an average reduction of 4% in the plan monitor units and 5% in the number of control points. Conclusion. Dose from daily kV CBCT has been added to patient treatment plans using previously commissioned kV CBCT beams in a treatment planning system. Addition of imaging dose can be included in IMRT treatment plan optimization and would facilitate customization of imaging protocol based on patient anatomy and location of isocenter.
引用
收藏
页码:839 / 844
页数:6
相关论文
共 25 条
[11]   Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit [J].
Downes, P. ;
Jarvis, R. ;
Radu, E. ;
Kawrakow, I. ;
Spezi, E. .
MEDICAL PHYSICS, 2009, 36 (09) :4156-4167
[12]   Patient dose and image quality from mega-voltage cone beam computed tomography imaging [J].
Gayou, Olivier ;
Parda, David S. ;
Johnson, Mark ;
Miften, Moyed .
MEDICAL PHYSICS, 2007, 34 (02) :499-506
[13]   Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy [J].
Islam, Mohammad K. ;
Purdie, Thomas G. ;
Norrlinger, Bernhard D. ;
Alasti, Hamideh ;
Moseley, Douglas J. ;
Sharpe, Michael B. ;
Siewerdsen, Jeffrey H. ;
Jaffray, David A. .
MEDICAL PHYSICS, 2006, 33 (06) :1573-1582
[14]   Fast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation [J].
Jia, Xun ;
Yan, Hao ;
Gu, Xuejun ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) :577-590
[15]   Radiation dose from cone beam computed tomography for image-guided radiation therapy [J].
Kan, Monica W. K. ;
Leung, Lucullus H. T. ;
Wong, Wicger ;
Lam, Nelson .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :272-279
[16]   IMRT planning and delivery incorporating daily dose from mega-voltage cone-beam computed tomography imaging [J].
Miften, Moyed ;
Gayou, Olivier ;
Reitz, Bodo ;
Fuhrer, Russell ;
Leicher, Brian ;
Parda, David S. .
MEDICAL PHYSICS, 2007, 34 (10) :3760-3767
[17]   Patient dose considerations for routine megavoltage cone-beam CT imaging [J].
Morin, Olivier ;
Gillis, Amy ;
Descovich, Martina ;
Chen, Josephine ;
Aubin, Michele ;
Aubry, Jean-Francois ;
Chen, Hong ;
Gottschalk, Alexander R. ;
Xia, Ping ;
Pouliot, Jean .
MEDICAL PHYSICS, 2007, 34 (05) :1819-1827
[18]   Estimation of organ and effective doses resulting from cone beam CT imaging for radiotherapy treatment planning [J].
Sawyer, L. J. ;
Whittle, S. A. ;
Matthews, E. S. ;
Starritt, H. C. ;
Jupp, T. P. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (979) :577-584
[19]   A dose comparison study between XVI® and OBI® CBCT systems [J].
Song, William Y. ;
Kamath, Srijit ;
Ozawal, Shuichi ;
Al Ani, Shlomi ;
Chvetsov, Alexei ;
Lhandare, Niranjan ;
Palta, Jatinder R. ;
Liu, Chihray ;
Li, Jonathan G. .
MEDICAL PHYSICS, 2008, 35 (02) :480-486
[20]   Patient-Specific Three-Dimensional Concomitant Dose From Cone Beam Computed Tomography Exposure in Image-Guided Radiotherapy [J].
Spezi, Emiliano ;
Downes, Patrick ;
Jarvis, Richard ;
Radu, Emil ;
Staffurth, John .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01) :419-426