Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair

被引:23
作者
Desimone, Christopher V. [1 ]
Hu, Tiffany [2 ]
Ebrille, Elisa [1 ,3 ]
Syed, Faisal F. [1 ]
Vaidya, Vaibhav R. [4 ]
Cha, Yong-Mei [1 ]
Valverde, Arturo M. [5 ]
Friedman, Paul A. [1 ]
Suri, Rakesh M. [6 ]
Asirvatham, Samuel J. [1 ,7 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Dept Internal Med, Rochester, MN 55905 USA
[2] Mayo Clin, Mayo Clin Sch Med, Rochester, MN 55905 USA
[3] Univ Turin, Dept Internal Med, Div Cardiovasc Dis Citta Salute & Sci, Turin, Italy
[4] Mayo Clin, Dept Internal Med, Rochester, MN USA
[5] Mayo Clin Hlth Syst, Dept Cardiovasc Dis, Eau Claire, WI USA
[6] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[7] Mayo Clin, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
关键词
atrial fibrillation; catheter ablation; mitral valve damage; ventricular tachycardia; WPW syndrome; CIRCULAR MAPPING CATHETER; RADIOFREQUENCY ABLATION; ENTRAPMENT; APPARATUS; REGURGITATION; COMPLICATION; RELEASE;
D O I
10.1111/jce.12439
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Mitral Valve Injury with Catheter Ablation. Introduction: An increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation-related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes. Methods: We searched the Mayo Clinic MV surgical database over a 19-year period (1993-2012) and the electrophysiologic procedures database over a 23-year period (1990-2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention. Results: Indications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left-sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure. Conclusion: Circular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
引用
收藏
页码:971 / 975
页数:5
相关论文
共 18 条
  • [1] Mitral Valve Injury After Radiofrequency Ablation for Wolff-Parkinson-White Syndrome
    Canal, Juan G. Penaranda
    Enriquez-Sarano, Maurice
    Asirvatham, Samuel J.
    Munger, Thomas M.
    Friedman, Paul A.
    Suri, Rakesh M.
    [J]. CIRCULATION, 2013, 127 (25) : 2551 - 2552
  • [2] Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation
    Cappato, R
    Calkins, H
    Chen, SA
    Davies, W
    Iesaka, Y
    Kalman, J
    Kim, YH
    Klein, G
    Packer, D
    Skanes, A
    [J]. CIRCULATION, 2005, 111 (09) : 1100 - 1105
  • [3] CATHETER ENTRAPMENT IN THE MITRAL-VALVE APPARATUS DURING RADIOFREQUENCY ABLATION
    CONTI, JB
    GEISER, E
    CURTIS, AB
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (10): : 1681 - 1685
  • [4] Fisch-Thomsen M, 2011, J HEART VALVE DIS, V20, P351
  • [5] Electrophysiological breakthroughs from the left atrium to the pulmonary veins
    Haïssaguerre, M
    Shah, DC
    Jaïs, P
    Hocini, M
    Yamane, T
    Deisenhofer, I
    Chauvin, M
    Garrigue, S
    Clémenty, J
    [J]. CIRCULATION, 2000, 102 (20) : 2463 - 2465
  • [6] Minimally invasive surgical release of entrapped mapping catheter in the mitral valve
    Je, Hyung Gon
    Kim, Jeong Won
    Jung, Sung Ho
    Lee, Jae Won
    [J]. CIRCULATION JOURNAL, 2008, 72 (08) : 1378 - 1380
  • [7] Entrapment of circular mapping catheter in the mitral valve
    Kesek, Milos
    Englund, Anders
    Jensen, Steen M.
    Jensen-Urstad, Mats
    [J]. HEART RHYTHM, 2007, 4 (01) : 17 - 19
  • [8] Correlative Anatomy for the Electrophysiologist: Ablation for Atrial Fibrillation. Part II: Regional Anatomy of the Atria and Relevance to Damage of Adjacent Structures During AF Ablation
    Macedo, Paula G.
    Kapa, Suraj
    Mears, Jennifer A.
    Fratianni, Amy
    Asirvatham, Samuel J.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (07) : 829 - 836
  • [9] Catheter entrapment in the mitral valve apparatus requiring surgical removal: An unusual complication of radiofrequency ablation
    Mandawat, MK
    Turitto, G
    El-Sherif, N
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (04): : 772 - 773
  • [10] Successful release of entrapped circumferential mapping catheters in patients undergoing pulmonary vein isolation for atrial fibrillation
    Mansour, M
    Mela, T
    Ruskin, J
    Keane, D
    [J]. HEART RHYTHM, 2004, 1 (05) : 558 - 561