A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array

被引:20
|
作者
Baek, Jongduk [1 ]
De Man, Bruno [2 ]
Uribe, Jorge [2 ]
Longtin, Randy [2 ]
Harrison, Daniel [2 ]
Reynolds, Joseph [2 ]
Neculaes, Bogdan [2 ]
Frutschy, Kristopher [2 ]
Inzinna, Louis [2 ]
Caiafa, Antonio [2 ]
Senzig, Robert [3 ]
Pelc, Norbert J. [4 ,5 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Inchon 406840, South Korea
[2] GE Global Res, Niskayuna, NY USA
[3] GE Healthcare, Waukesha, WI USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 05期
关键词
CT; inverse geometry; multiple source array; image quality; NOISE POWER SPECTRUM; COMPUTED-TOMOGRAPHY; RECONSTRUCTION;
D O I
10.1088/0031-9155/59/5/1189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present initial experimental results of a rotating-gantry multi-source inverse-geometry CT (MS-IGCT) system. The MS-IGCT system was built with a single module of 2 x 4 x-ray sources and a 2D detector array. It produced a 75 mm in-plane field-of-view (FOV) with 160 mm axial coverage in a single gantry rotation. To evaluate system performance, a 2.5 inch diameter uniform PMMA cylinder phantom, a 200 mu m diameter tungsten wire, and a euthanized rat were scanned. Each scan acquired 125 views per source and the gantry rotation time was 1 s per revolution. Geometric calibration was performed using a bead phantom. The scanning parameters were 80 kVp, 125 mA, and 5.4 mu s pulse per source location per view. A data normalization technique was applied to the acquired projection data, and beam hardening and spectral nonlinearities of each detector channel were corrected. For image reconstruction, the projection data of each source row were rebinned into a full cone beam data set, and the FDK algorithm was used. The reconstructed volumes from upper and lower source rows shared an overlap volume which was combined in image space. The images of the uniform PMMA cylinder phantom showed good uniformity and no apparent artifacts. The measured in-plane MTF showed 13 lp cm(-1) at 10% cutoff, in good agreement with expectations. The rat data were also reconstructed reliably. The initial experimental results from this rotating-gantry MS-IGCT system demonstrated its ability to image a complex anatomical object without any significant image artifacts and to achieve high image resolution and large axial coverage in a single gantry rotation.
引用
收藏
页码:1189 / 1202
页数:14
相关论文
共 50 条
  • [41] Quantitative characterization of an x-ray source in an x-ray photoelectron spectroscopy system
    Pepper, SV
    Wheeler, DR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1509 - 1515
  • [42] Development of an X-ray photoelectron microscopic system with a compact X-ray source
    Fujikawa, C
    Yamaguchi, N
    Ohchi, T
    Hara, T
    Watanabe, K
    Tanaka, I
    Taguchi, M
    LASER AND PARTICLE BEAMS, 2002, 20 (01) : 39 - 42
  • [43] Development of x-ray photoelectron microscopic system with a compact x-ray source
    Fujikawa, C
    Yamaguchi, N
    Ohchi, T
    Ham, T
    Watanabe, K
    Tanaka, I
    Taguchi, M
    ECLIM 2000: 26TH EUROPEAN CONFERENCE ON LASER INTERACTION WITH MATTER, 2001, 4424 : 422 - 425
  • [44] Ray Tracing Simulation of X-ray Microdiffraction Beamline on the Inverse Compton Source
    Vinogradov, Alexander
    Feshchenko, Ruslan
    Shvedunov, Vasiliy
    Artyukov, Igor
    SYMMETRY-BASEL, 2023, 15 (05):
  • [45] Simulation study of a novel small animal FLASH irradiator (SAFI) with integrated inverse-geometry CT based on circularly distributed kV X-ray sources
    Yuewen Tan
    Shuang Zhou
    Jonathan Haefner
    Qinghao Chen
    Thomas R. Mazur
    Arash Darafsheh
    Tiezhi Zhang
    Scientific Reports, 13
  • [46] A beam optics study of a modular multi-source X-ray tube for novel computed tomography applications
    Walker, Brandon J.
    Radtke, Jeff
    Chen, Guang-Hong
    Eliceiri, Kevin W.
    Mackie, Thomas R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 868 : 1 - 9
  • [47] UniChest: Conquer-and-Divide Pre-Training for Multi-Source Chest X-Ray Classification
    Dai, Tianjie
    Zhang, Ruipeng
    Hong, Feng
    Yao, Jiangchao
    Zhang, Ya
    Wang, Yanfeng
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (08) : 2901 - 2912
  • [48] On a new multi-source X-ray tube concept for minimizing imaging time in digital breast tomosynthesis
    Behling, Rolf
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 20 - 22
  • [49] Dual-energy X-ray CT by Compton scattering hard X-ray source
    Kaneyasu, T
    Uesaka, N
    Dobashi, K
    Torikoshi, M
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1680 - 1682
  • [50] Simulation study of a novel small animal FLASH irradiator (SAFI) with integrated inverse-geometry CT based on circularly distributed kV X-ray sources
    Tan, Yuewen
    Zhou, Shuang
    Haefner, Jonathan
    Chen, Qinghao
    Mazur, Thomas R.
    Darafsheh, Arash
    Zhang, Tiezhi
    SCIENTIFIC REPORTS, 2023, 13 (01)