A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array

被引:20
|
作者
Baek, Jongduk [1 ]
De Man, Bruno [2 ]
Uribe, Jorge [2 ]
Longtin, Randy [2 ]
Harrison, Daniel [2 ]
Reynolds, Joseph [2 ]
Neculaes, Bogdan [2 ]
Frutschy, Kristopher [2 ]
Inzinna, Louis [2 ]
Caiafa, Antonio [2 ]
Senzig, Robert [3 ]
Pelc, Norbert J. [4 ,5 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Inchon 406840, South Korea
[2] GE Global Res, Niskayuna, NY USA
[3] GE Healthcare, Waukesha, WI USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 05期
关键词
CT; inverse geometry; multiple source array; image quality; NOISE POWER SPECTRUM; COMPUTED-TOMOGRAPHY; RECONSTRUCTION;
D O I
10.1088/0031-9155/59/5/1189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present initial experimental results of a rotating-gantry multi-source inverse-geometry CT (MS-IGCT) system. The MS-IGCT system was built with a single module of 2 x 4 x-ray sources and a 2D detector array. It produced a 75 mm in-plane field-of-view (FOV) with 160 mm axial coverage in a single gantry rotation. To evaluate system performance, a 2.5 inch diameter uniform PMMA cylinder phantom, a 200 mu m diameter tungsten wire, and a euthanized rat were scanned. Each scan acquired 125 views per source and the gantry rotation time was 1 s per revolution. Geometric calibration was performed using a bead phantom. The scanning parameters were 80 kVp, 125 mA, and 5.4 mu s pulse per source location per view. A data normalization technique was applied to the acquired projection data, and beam hardening and spectral nonlinearities of each detector channel were corrected. For image reconstruction, the projection data of each source row were rebinned into a full cone beam data set, and the FDK algorithm was used. The reconstructed volumes from upper and lower source rows shared an overlap volume which was combined in image space. The images of the uniform PMMA cylinder phantom showed good uniformity and no apparent artifacts. The measured in-plane MTF showed 13 lp cm(-1) at 10% cutoff, in good agreement with expectations. The rat data were also reconstructed reliably. The initial experimental results from this rotating-gantry MS-IGCT system demonstrated its ability to image a complex anatomical object without any significant image artifacts and to achieve high image resolution and large axial coverage in a single gantry rotation.
引用
收藏
页码:1189 / 1202
页数:14
相关论文
共 50 条
  • [1] Initial results with a multi-source inverse-geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    Deman, Bruno
    Uribe, Jorge
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Inzinna, Louis
    Caiafa, Antonio
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [2] Multi-source inverse-geometry CT: from system concept to research prototype
    De Man, Bruno
    Caiafa, Antonio
    Cao, Yang
    Frutschy, Kristopher
    Harrison, Daniel
    Inzinna, Lou
    Longtin, Randy
    Neculaes, Bogdan
    Reynolds, Joseph
    Roy, Jaydeep
    Short, Jonathan
    Uribe, Jorge
    Waters, William
    Yin, Zhye
    Zhang, Xi
    Zou, Yun
    Senzig, Bob
    Baek, Jongduk
    Pelc, Norbert
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3531 - +
  • [3] Multi-source inverse geometry CT :: a new system concept for X-ray computed tomography
    De Man, Bruno
    Basu, Samit
    Beque, Dirk
    Claus, Bernhard
    Edic, Pete
    Iatrou, Maria
    LeBlanc, James
    Senzig, Bob
    Thompson, Richard
    Vermilyea, Mark
    Wilson, Colin
    Yin, Zhye
    Pelc, Norbert
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [4] Preliminary study on optimization of the stationary inverse-geometry digital tomosynthesis: X-ray source array
    Kim, Burnyoung
    Eom, Jisoo
    Kim, Wonhyung
    Lee, Seungwan
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [5] Multisource inverse-geometry CT. Part II. X-ray source design and prototype
    Neculaes, V. Bogdan
    Caiafa, Antonio
    Cao, Yang
    De Man, Bruno
    Edic, Peter M.
    Frutschy, Kristopher
    Gunturi, Satish
    Inzinna, Lou
    Reynolds, Joseph
    Vermilyea, Mark
    Wagner, David
    Zhang, Xi
    Zou, Yun
    Pelc, Norbert J.
    Lounsberry, Brian
    MEDICAL PHYSICS, 2016, 43 (08) : 4617 - 4627
  • [6] Optimization of a multi-source rectangular X-ray CT geometry for inline inspection
    Bossuyt, C.
    De Beenhouwer, J.
    Sijbers, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [7] Dynamic X-ray Flux Modulation of Inverse-Geometry CT
    Shen, Liuxing
    Windsor, Haydon
    Zhou, Shuang
    Jiang, Hao
    Zhang, Tiezhi
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [8] Data normalization method for a multi-source inverse geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [9] A volumetric reconstruction algorithm for stationary source inverse-geometry CT
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [10] Analytical cone-beam reconstruction using a multi-source inverse geometry CT system
    Yin, Zhye
    De Man, Bruno
    Pack, Jed
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510