Radiation Dose Metrics in CT: Assessing Dose Using the National Quality Forum CT Patient Safety Measure

被引:10
作者
Keegan, Jillian [1 ]
Miglioretti, Diana L. [2 ]
Gould, Robert [1 ]
Donnelly, Lane F. [3 ]
Wilson, Nicole D. [1 ]
Smith-Bindman, Rebecca [1 ,4 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif Davis, Dept Publ Hlth Sci, Davis, CA 95616 USA
[3] Nemours Childrens Hosp, Off Chief Med Officer, Orlando, FL USA
[4] Univ Calif San Francisco, Dept Epidemiol & Biostat, San Francisco, CA 94143 USA
[5] Univ Calif San Francisco, Dept Obstet Gynecol & Reprod Sci, San Francisco, CA 94143 USA
关键词
CT; dose metrics; radiation; quality improvement; COMPUTED-TOMOGRAPHY; EXPOSURE; RISK;
D O I
10.1016/j.jacr.2013.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The National Quality Forum (NQF) is a nonprofit consensus organization that recently endorsed a measure focused on CT radiation doses. To comply, facilities must summarize the doses from consecutive scans within age and anatomic area strata and report the data in the medical record. Our purpose was to assess the time needed to assemble the data and to demonstrate how review of such data permits a facility to understand doses. Methods and Materials: To assemble the data we used for analysis, we used the dose monitoring software eXposure to automatically export dose metrics from consecutive scans in 2010 and 2012. For a subset of 50 exams, we also collected dose metrics manually, copying data directly from the PACS into an excel spreadsheet. Results: Manual data collection for 50 scans required 2 hours and 15 minutes. eXposure compiled the data in under an hour. All dose metrics demonstrated a 30% to 50% reduction between 2010 and 2012. There was also a significant decline and a reduction in the variability of the doses over time. Conclusion: The NQF measure facilitates an institution's capacity to assess the doses they are using for CT as part of routine practice. The necessary data can be collected within a reasonable amount of time either with automatic software or manually. The collection and review of these data will allow facilities to compare their radiation dose distributions with national distributions and allow assessment of temporal trends in the doses they are using.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 50 条
  • [41] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    David B. Larson
    Pediatric Radiology, 2014, 44 : 501 - 505
  • [42] CT radiation dose awareness among paediatricians
    Al-Rammah, Tamader Y.
    ITALIAN JOURNAL OF PEDIATRICS, 2016, 42
  • [43] Image texture and radiation dose properties in CT
    Mozejko, Dawid
    Andersen, Hilde Kjernlie
    Pedersen, Marius
    Waaler, Dag
    Martinsen, Anne Catrine Traegde
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 408 - 418
  • [44] Radiation dose of cardiac CT—what is the evidence?
    Hatem Alkadhi
    European Radiology, 2009, 19 : 1311 - 1315
  • [45] RADIATION DOSE DETERMINATION IN ABDOMINAL CT EXAMINATIONS OF CHILDREN AT SUDANESE HOSPITALS USING SIZE-SPECIFIC DOSE ESTIMATES
    Bashier, Einas H.
    Suliman, I. I.
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 444 - 449
  • [46] Size based dependence of patient dose metrics, and image quality metrics for clinical indicator-based imaging protocols in abdominal CT procedures
    Sebelego, I.
    Acho, S.
    van der Merwe, B.
    Rae, W. I. D.
    RADIOGRAPHY, 2023, 29 (06) : 961 - 974
  • [47] Radiation dose to the lens from CT of the head in young people
    Harbron, R. W.
    Ainsbury, E. A.
    Barnard, S. G. R.
    Lee, C.
    McHugh, K.
    de Gonzalez, A. Berrington
    Edyvean, S.
    Pearce, M. S.
    CLINICAL RADIOLOGY, 2019, 74 (10) : 816.e9 - 816.e17
  • [48] Minimizing Radiation Dose for Coronary CT Angiography
    Vorobiof, Gabriel
    Achenbach, Stephan
    Narula, Jagat
    CARDIOLOGY CLINICS, 2012, 30 (01) : 9 - +
  • [49] Comparison of Radiation Dose and Image Quality of Abdominopelvic CT Using Iterative (AIDR 3D) and Conventional Reconstructions
    de Mello-Amoedo, Caroline Duarte
    Martins, Aparecido Nakano
    Tachibana, Adriano
    Pinho, Daniella Ferraro
    Baroni, Ronaldo Hueb
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (01) : 127 - 133
  • [50] Dedicated breast CT: Radiation dose and image quality evaluation
    Boone, JM
    Nelson, TR
    Lindfors, KK
    Seibert, JA
    RADIOLOGY, 2001, 221 (03) : 657 - 667