Radiation Dose Metrics in CT: Assessing Dose Using the National Quality Forum CT Patient Safety Measure

被引:10
作者
Keegan, Jillian [1 ]
Miglioretti, Diana L. [2 ]
Gould, Robert [1 ]
Donnelly, Lane F. [3 ]
Wilson, Nicole D. [1 ]
Smith-Bindman, Rebecca [1 ,4 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif Davis, Dept Publ Hlth Sci, Davis, CA 95616 USA
[3] Nemours Childrens Hosp, Off Chief Med Officer, Orlando, FL USA
[4] Univ Calif San Francisco, Dept Epidemiol & Biostat, San Francisco, CA 94143 USA
[5] Univ Calif San Francisco, Dept Obstet Gynecol & Reprod Sci, San Francisco, CA 94143 USA
关键词
CT; dose metrics; radiation; quality improvement; COMPUTED-TOMOGRAPHY; EXPOSURE; RISK;
D O I
10.1016/j.jacr.2013.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The National Quality Forum (NQF) is a nonprofit consensus organization that recently endorsed a measure focused on CT radiation doses. To comply, facilities must summarize the doses from consecutive scans within age and anatomic area strata and report the data in the medical record. Our purpose was to assess the time needed to assemble the data and to demonstrate how review of such data permits a facility to understand doses. Methods and Materials: To assemble the data we used for analysis, we used the dose monitoring software eXposure to automatically export dose metrics from consecutive scans in 2010 and 2012. For a subset of 50 exams, we also collected dose metrics manually, copying data directly from the PACS into an excel spreadsheet. Results: Manual data collection for 50 scans required 2 hours and 15 minutes. eXposure compiled the data in under an hour. All dose metrics demonstrated a 30% to 50% reduction between 2010 and 2012. There was also a significant decline and a reduction in the variability of the doses over time. Conclusion: The NQF measure facilitates an institution's capacity to assess the doses they are using for CT as part of routine practice. The necessary data can be collected within a reasonable amount of time either with automatic software or manually. The collection and review of these data will allow facilities to compare their radiation dose distributions with national distributions and allow assessment of temporal trends in the doses they are using.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 50 条
  • [31] TOWARDS DOSE REDUCTION IN CT: PATIENT RADIATION DOSE ASSESSMENT FOR CT EXAMINATIONS AT UNIVERSITY HEALTH CENTER IN CANADA AND COMPARISON WITH NATIONAL DIAGNOSTIC REFERENCE LEVELS
    Heliou, Regis
    Normandeau, Lysanne
    Beaudoin, Gilles
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (02) : 202 - 210
  • [32] Radiation dose reduction by using low dose CT protocol of thorax
    Ramac, J. Popic
    Knezevic, Z.
    Hebrang, A.
    Kristo, D. Radic
    Vidjak, V.
    Slavica, M.
    Ranogajec-Komor, M.
    RADIATION MEASUREMENTS, 2013, 55 : 46 - 50
  • [33] Impact of head CT organ dose modulation on lens dose and image quality
    Dalah, Entesar Z.
    Grazyna, Wasilewska
    Al Bastaki, Usama M.
    Abedzadeh, Ayoub A.
    AL Musfari, Yousuf M.
    Khan, Sabaa A.
    Elawad, Noon M.
    Bradley, David A.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [34] Radiation Dose in Cardiac CT
    Mayo, John R.
    Leipsic, Jonathon A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 646 - 653
  • [35] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [36] Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Toncheva, Greta
    Yoshizumi, Terry T.
    Frush, Donald P.
    MEDICAL PHYSICS, 2011, 38 (01) : 408 - 419
  • [37] Patient dose estimation in CT examination using dose conversion coefficient method and CT -expo software
    Kofi Okyere Akyea-Larbi
    Francis Hasford
    Stephen Inkoom
    Mercy Afadzi Tetteh
    Health and Technology, 2022, 12 : 809 - 814
  • [38] Patient dose estimation in CT examination using dose conversion coefficient method and CT -expo software
    Akyea-Larbi, Kofi Okyere
    Hasford, Francis
    Inkoom, Stephen
    Tetteh, Mercy Afadzi
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 809 - 814
  • [39] Evaluation of Impact of Factors Affecting CT Radiation Dose for Optimizing Patient Dose Levels
    Yang, Ching-Ching
    DIAGNOSTICS, 2020, 10 (10)
  • [40] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    Larson, David B.
    PEDIATRIC RADIOLOGY, 2014, 44 : 501 - 505