Radiation Dose Metrics in CT: Assessing Dose Using the National Quality Forum CT Patient Safety Measure

被引:10
|
作者
Keegan, Jillian [1 ]
Miglioretti, Diana L. [2 ]
Gould, Robert [1 ]
Donnelly, Lane F. [3 ]
Wilson, Nicole D. [1 ]
Smith-Bindman, Rebecca [1 ,4 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif Davis, Dept Publ Hlth Sci, Davis, CA 95616 USA
[3] Nemours Childrens Hosp, Off Chief Med Officer, Orlando, FL USA
[4] Univ Calif San Francisco, Dept Epidemiol & Biostat, San Francisco, CA 94143 USA
[5] Univ Calif San Francisco, Dept Obstet Gynecol & Reprod Sci, San Francisco, CA 94143 USA
关键词
CT; dose metrics; radiation; quality improvement; COMPUTED-TOMOGRAPHY; EXPOSURE; RISK;
D O I
10.1016/j.jacr.2013.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The National Quality Forum (NQF) is a nonprofit consensus organization that recently endorsed a measure focused on CT radiation doses. To comply, facilities must summarize the doses from consecutive scans within age and anatomic area strata and report the data in the medical record. Our purpose was to assess the time needed to assemble the data and to demonstrate how review of such data permits a facility to understand doses. Methods and Materials: To assemble the data we used for analysis, we used the dose monitoring software eXposure to automatically export dose metrics from consecutive scans in 2010 and 2012. For a subset of 50 exams, we also collected dose metrics manually, copying data directly from the PACS into an excel spreadsheet. Results: Manual data collection for 50 scans required 2 hours and 15 minutes. eXposure compiled the data in under an hour. All dose metrics demonstrated a 30% to 50% reduction between 2010 and 2012. There was also a significant decline and a reduction in the variability of the doses over time. Conclusion: The NQF measure facilitates an institution's capacity to assess the doses they are using for CT as part of routine practice. The necessary data can be collected within a reasonable amount of time either with automatic software or manually. The collection and review of these data will allow facilities to compare their radiation dose distributions with national distributions and allow assessment of temporal trends in the doses they are using.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 50 条
  • [1] CT Dose Metrics
    Huda, Walter
    RADIOLOGY, 2013, 267 (03) : 964 - 965
  • [2] Reducing Radiation Dose in Body CT: A Primer on Dose Metrics and Key CT Technical Parameters
    Maldjian, Pierre D.
    Goldman, Alice R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 741 - 747
  • [3] CT radiation dose and image quality
    Payne, JT
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) : 953 - +
  • [4] Reducing Variability of Radiation Dose in CT: The New Frontier in Patient Safety
    Lee, Ryan K.
    Sun, Joel Y.
    Lockerby, Samantha
    Soltycki, Eric
    Matalon, Terence
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (11) : 1633 - 1641
  • [5] A national survey on radiation dose in CT in The Netherlands
    van der Molen, A. J.
    Schilham, A.
    Stoop, P.
    Prokop, M.
    Geleijns, J.
    INSIGHTS INTO IMAGING, 2013, 4 (03): : 383 - 390
  • [6] A national survey on radiation dose in CT in The Netherlands
    A. J. van der Molen
    A. Schilham
    P. Stoop
    M. Prokop
    J. Geleijns
    Insights into Imaging, 2013, 4 (3) : 383 - 390
  • [7] Automated Patient-Specific CT Dose Monitoring System: Assessing Variability in CT Dose
    Christianson, O.
    Li, X.
    Frush, D.
    Samei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] CT arthrography of the human knee to measure cartilage quality with low radiation dose
    van Tiel, J.
    Siebelt, M.
    Waarsing, J. H.
    Piscaer, T. M.
    van Straten, M.
    Booij, R.
    Dijkshoorn, M. L.
    Kleinrensink, G. J.
    Verhaar, J. A. N.
    Krestin, G. P.
    Weinans, H.
    Oei, E. H. G.
    OSTEOARTHRITIS AND CARTILAGE, 2012, 20 (07) : 678 - 685
  • [9] CT Dose Metrics Response
    Bankier, Alexander A.
    Kressel, Herbert Y.
    RADIOLOGY, 2013, 267 (03) : 966 - 966
  • [10] IMPLEMENTATION OF MODULATED LOW DOSE CT FOR PET/CT SCANS TO REDUCE RADIATION DOSE TO PATIENT
    Ng, W.
    Welch, J.
    Pathmaraj, K.
    Scott, A.
    INTERNAL MEDICINE JOURNAL, 2017, 47 : 33 - 33