Chemical exchange saturation transfer MRI using intermolecular double-quantum coherences with multiple refocusing pulses

被引:3
作者
Lu, Jianhua [1 ]
Cai, Congbo [2 ]
Cai, Shuhui [1 ]
Chen, Zhong [1 ]
Zhou, Jinyuan [3 ]
机构
[1] Xiamen Univ, Dept Elect Sci, Fujian Prov Key Lab Plasma & Magnet Resonance, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Dept Commun Engn, Xiamen 361005, Peoples R China
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
基金
美国国家卫生研究院; 中国国家自然科学基金;
关键词
CEST; MRI; Intermolecular double-quantum coherence; Image contrast; Nuclear Overhauser enhancement; DIPOLAR FIELD; IN-VIVO; HUMAN BRAIN; 7; T; INHOMOGENEOUS FIELDS; SIGNAL ENHANCEMENT; CONTRAST AGENTS; TRANSFER CEST; SOLUTION NMR; RELAXATION;
D O I
10.1016/j.mri.2014.03.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chemical exchange saturation transfer (CEST) provides a new type of image contrast in MRI. Due to the intrinsically low CEST effect, new and improved experimental techniques are required to achieve reliable and quantitative CEST images. In the present work, we proposed a novel and more sensitive CEST acquisition approach, based on the intermolecular double-quantum coherence with a module of multiple refocusing pulses (iDQC-MRP). Experiments were performed on creatine and egg white phantoms using a Varian 7 T animal MRI scanner. The iDQC-MRP CEST technique showed a substantial enhancement in CEST and nuclear Overhauser enhancement (NOE) signal intensities, compared to the standard single-quantum coherence approach. In addition, the iDQC-MRP approach increased the signal-to-noise ratio of acquired saturation images, compared to the conventional iDQC approach. The new iDQC-MRP CEST sequence provides a promising way for exploiting in vivo CEST and NOE imaging applications. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:759 / 765
页数:7
相关论文
共 50 条
  • [1] Chemical exchange saturation transfer by intermolecular double-quantum coherence
    Ling, Wen
    Eliav, Uzi
    Navon, Gil
    Jerschow, Alexej
    JOURNAL OF MAGNETIC RESONANCE, 2008, 194 (01) : 29 - 32
  • [2] Isolating quantum coherences in structural imaging using intermolecular double-quantum coherence MRI
    Chin, CL
    Tang, XP
    Bouchard, LS
    Saha, PK
    Warren, WS
    Wehrli, FW
    JOURNAL OF MAGNETIC RESONANCE, 2003, 165 (02) : 309 - 314
  • [3] Clinical applications of chemical exchange saturation transfer (CEST) MRI
    Jones, Kyle M.
    Pollard, Alyssa C.
    Pagel, Mark D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (01) : 11 - 27
  • [4] pH Imaging Using Chemical Exchange Saturation Transfer (CEST) MRI
    Pavuluri, KowsalyaDevi
    McMahon, Michael T.
    ISRAEL JOURNAL OF CHEMISTRY, 2017, 57 (09) : 862 - 879
  • [5] Chemical Exchange Saturation Transfer (CEST) Agents: Quantum Chemistry and MRI
    Li, Jikun
    Feng, Xinxin
    Zhu, Wei
    Oskolkov, Nikita
    Zhou, Tianhui
    Kim, Boo Kyung
    Baig, Noman
    McMahon, Michael T.
    Oldfield, Eric
    CHEMISTRY-A EUROPEAN JOURNAL, 2016, 22 (01) : 264 - 271
  • [6] Resolution enhancement in MR spectroscopy of red bone marrow fat via intermolecular double-quantum coherences
    Bao, Jianfeng
    Cui, Xiaohong
    Huang, Yuqing
    Zhong, Jianhui
    Chen, Zhong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) : 6391 - 6406
  • [7] Visualization of Injectable Hydrogels Using Chemical Exchange Saturation Transfer MRI
    Dorsey, Shauna M.
    Haris, Mohammad
    Singh, Anup
    Witschey, Walter R. T.
    Rodell, Christopher B.
    Kogan, Feliks
    Reddy, Ravinder
    Burdick, Jason A.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2015, 1 (04): : 227 - 237
  • [8] Hadamard-encoded localized high-resolution NMR spectroscopy via intermolecular double-quantum coherences
    Ke, Hanping
    Cai, Honghao
    Lin, Yanqin
    Lin, Liangjie
    Cai, Shuhui
    Chen, Zhong
    CHEMICAL PHYSICS LETTERS, 2015, 622 : 63 - 68
  • [9] Intermolecular double-quantum coherence imaging without coherence selection gradients and its application in in vivo MRI
    Shen, Guiping
    Cai, Congbo
    Chen, Zhong
    Cai, Shuhui
    MAGNETIC RESONANCE IMAGING, 2013, 31 (04) : 515 - 523
  • [10] Investigating Hydroxyl Chemical Exchange Using a Variable Saturation Power Chemical Exchange Saturation Transfer (vCEST) Method at 3 T
    Clark, Daniel James
    Smith, Alex K.
    Dortch, Richard D.
    Knopp, Michael V.
    Smith, Seth A.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 826 - 837