Randomized trial of a biofragmentable bowel anastomosis ring in high-risk colonic resection

被引:0
作者
Pahlman, L
Ejerblad, S
Graf, W
Kader, F
Kressner, U
Lindmark, G
Raab, Y
机构
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Biofragmentable anastomosis ring (BAR) has been proven to be a safe anastomotic device in elective surgery. The use of this anastomotic ring in high-risk patients has not been established. Methods During a 5-year period (1990-1995), 100 high-risk patients undergoing colonic resection and suitable for a primary anastomosis were allocated randomly to a standard suture technique or to anastomosis performed with a BAR. High risk was defined as large bowel obstruction, complicated diverticular disease, Crohn's disease, local cancer recurrence, previously irradiated colon, and trauma to the colon or rectum. The patients were equally distributed to the two groups regarding sex, age, emergency surgery and concomitant diseases. Results In three patients allotted to the BAR group, the device could not be used. There were three (6 per cent) postoperative deaths in each group; none was related to anastomotic problems. Three anastomotic dehiscences were diagnosed, two (4 per cent) in the BAR group and one (2 per cent) in the suture group. Postoperative complications and postoperative recovery were similar. Conclusion This study shows that the BAR anastomosis probably is as safe as the standard hand-sewn anastomosis in high-risk colorectal surgery. As the cost of a BAR anastomosis is substantially higher than that for a hand-sewn anastomosis, the latter technique is still the preferred method in the authors' unit.
引用
收藏
页码:1291 / 1294
页数:4
相关论文
共 11 条
  • [1] SUTURELESS LARGE BOWEL ANASTOMOSIS - EUROPEAN-EXPERIENCE WITH THE BIOFRAGMENTABLE ANASTOMOSIS RING
    CAHILL, CJ
    BETZLER, M
    GRUWEZ, JA
    JEEKEL, J
    PATEL, JC
    ZEDERFELDT, B
    [J]. BRITISH JOURNAL OF SURGERY, 1989, 76 (04) : 344 - 347
  • [2] CHRISTIN A, 1994, MINERVA CHIR, V49, P1295
  • [3] CORMAN ML, 1989, DIS COLON RECTUM, V32, P182
  • [4] COLONIC ANASTOMOSIS USING THE BIOFRAGMENTABLE ANASTOMOTIC RING AND MANUAL SUTURE - A PROSPECTIVE, RANDOMIZED STUDY
    GULLICHSEN, R
    HAVIA, T
    OVASKA, J
    RANTALA, A
    [J]. BRITISH JOURNAL OF SURGERY, 1992, 79 (06) : 578 - 580
  • [5] WHAT HAPPENS TO THE VALTRAC(R) ANASTOMOSIS OF THE COLON - A FOLLOW-UP-STUDY
    GULLICHSEN, R
    OVASKA, J
    HAVIA, T
    YRJANA, J
    EKFORS, T
    [J]. DISEASES OF THE COLON & RECTUM, 1993, 36 (04) : 362 - 365
  • [6] A BIOFRAGMENTABLE RING FOR SUTURELESS BOWEL ANASTOMOSIS - AN EXPERIMENTAL-STUDY
    HARDY, TG
    PACE, WG
    MANEY, JW
    KATZ, AR
    KAGANOV, AL
    [J]. DISEASES OF THE COLON & RECTUM, 1985, 28 (07) : 484 - 490
  • [7] INITIAL CLINICAL-EXPERIENCE WITH A BIOFRAGMENTABLE RING FOR SUTURELESS BOWEL ANASTOMOSIS
    HARDY, TG
    AGUILAR, PS
    STEWART, WRC
    KATZ, AR
    MANEY, JW
    COSTANZO, JT
    PACE, WG
    [J]. DISEASES OF THE COLON & RECTUM, 1987, 30 (01) : 55 - 61
  • [8] LUUKKONEN P, 1990, ACTA CHIR SCAND, V156, P795
  • [9] CIRCULAR STAPLERS VERSUS THE BIOFRAGMENTABLE RING FOR COLORECTAL ANASTOMOSIS - A PROSPECTIVE RANDOMIZED STUDY
    SEOWCHOEN, F
    EU, KW
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (12) : 1790 - 1791
  • [10] THIEDE A, 1991, CHIRURG, V62, P819