Light leakage effects with different sample holder geometries in quantitative near-infrared transmission spectroscopy of pharmaceutical tablets

被引:12
作者
Sparén, A [1 ]
Malm, M [1 ]
Josefson, M [1 ]
Folestad, S [1 ]
Johansson, J [1 ]
机构
[1] AstraZeneca R&D, Analyt Dev, S-43183 Molndal, Sweden
关键词
near-infrared transmission spectroscopy; NIR; light leakage; multivariate calibration; chemometrics; partial least-squares regression; PLS; precision;
D O I
10.1366/0003702021955367
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Transmission geometry is becoming an alternative to the conventional reflectance geometry in near-infrared (NIR) spectroscopy of pharmaceuticals. An advantage of transmission NIR is that it samples a volume whereas reflectance NIR merely samples the surface region of solid preparations. This leads to more representative measurements on complex matrices, such as some types of tablets. How,ever, more attention must be paid to sample presentation with respect to light leakage. An investigation of the effects of the light leakage obtained with different sample holder geometries on content calibrations for transmission NIR on tablets was performed. Two different model samples, a composite and a compact tablet, were measured in sample wells in which the diameters and heights were varied according to a multivariate design. This was done in order to simulate a mismatch between the tablet and the sample well. Partial least-squares (PLS) models were built and used to evaluate the significance of the sample well geometry. Liquid chromatography was used as a reference method. As expected, for both types of tablets it was found that a small mismatch in tablet-to-well diameter deteriorated the repeatability of the NIR spectra, although, unexpectedly, this gave the best predictions and more robust models. In all, this indicates that light leakage should not be minimized at calibration, but included as a factor in the multivariate model that spans the future expected variation in light leakage.
引用
收藏
页码:586 / 592
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]   Effective sample size in diffuse reflectance near-IR spectrometry [J].
Berntsson, O ;
Burger, T ;
Folestad, S ;
Danielsson, LG ;
Kuhn, J ;
Fricke, J .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :617-623
[3]  
BURGER T, 1998, THESIS BAYERISCHEN J
[4]   Near infrared transmittance analysis for the assay of solid pharmaceutical dosage forms [J].
Corti, P ;
Ceramelli, G ;
Dreassi, E ;
Mattii, S .
ANALYST, 1999, 124 (05) :755-758
[5]   Quantification of paracetamol in intact tablets using near-infrared transmittance spectroscopy [J].
Eustaquio, A ;
Graham, P ;
Jee, RD ;
Moffatt, AC ;
Trafford, AD .
ANALYST, 1998, 123 (11) :2303-2306
[6]  
*FOSS NIRS, 1996, INST US MAN, pCH4
[7]   LINEARIZATION AND SCATTER-CORRECTION FOR NEAR-INFRARED REFLECTANCE SPECTRA OF MEAT [J].
GELADI, P ;
MACDOUGALL, D ;
MARTENS, H .
APPLIED SPECTROSCOPY, 1985, 39 (03) :491-500
[8]   Vibrational spectrometry for the assessment of active substance in metoprolol tablets: A comparison between transmission and diffuse reflectance near-infrared spectrometry [J].
Gottfries, J ;
Depui, H ;
Fransson, M ;
Jongeneelen, M ;
Josefson, M ;
Langkilde, FW ;
Witte, DT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (11) :1495-1503
[9]  
Jedvert I, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P279
[10]   SOME APPLICATIONS OF NEAR-INFRARED REFLECTANCE ANALYSIS IN THE PHARMACEUTICAL-INDUSTRY [J].
MACDONALD, BF ;
PREBBLE, KA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1077-1085