Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code

被引:5
|
作者
Martins, M. C. [1 ]
Cordeiro, T. P. V. [1 ]
Silva, A. X. [1 ]
Souza-Santos, D. [2 ]
Queiroz-Filho, P. P. [2 ]
Hunt, J. G. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Ctr Tecnol, BR-21941914 Rio De Janeiro, Brazil
[2] Inst Radioprotecao & Dosimetria, Div Dosimetria, BR-22783127 Rio De Janeiro, RJ, Brazil
关键词
Voxel phantom; ICRP110; Geant4; RADIATION PROTECTION;
D O I
10.1016/j.radphyschem.2013.04.030
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The reference adult male voxel phantom recommended by International Commission on Radiological Protection no. 110 was implemented in the Geant4 Monte Carlo code. Geant4 was used to calculate Dose Conversion Coefficients (DCCs) expressed as dose deposited in organs per air kerma for photons, electrons and neutrons in the Annals of the ICRP. In this work the AP and PA irradiation geometries of the ICRP male phantom were simulated for the purpose of benchmarking the Geant4 code. Monoenergetic photons were simulated between 15 key and 10 MeV and the results were compared with ICRP 110, the VMC Monte Carlo code and the literature data available, presenting a good agreement. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 7 条
  • [1] An EGS4 based Monte Carlo code for the calculation of organ equivalent dose to a modified Yale voxel phantom
    Kramer, R
    Vieira, JW
    Lima, FRA
    Fuelle, D
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 465 - 473
  • [2] Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom
    Tzamicha, E.
    Yakoumakis, E.
    Tsalafoutas, I. A.
    Dimitriadis, A.
    Georgiou, E.
    Tsapaki, V.
    Chalazonitis, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 785 - 791
  • [3] MONTE CARLO SIMULATED DIAGNOSTIC X-RAY DOSE DISTRIBUTION IN A HUMAN VOXEL PHANTOM WITH VISUALISATION
    Sevcik, Aleksandras
    Adliene, Diana
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 122 - 125
  • [4] Dose Conversion Coefficients Based on Taiwanese Reference Phantoms and Monte Carlo Simulations for Use in External Radiation Protection
    Chang, Shu-Jun
    Hsu, Jui-Ting
    Hung, Shih-Yen
    Liu, Yan-Lin
    Jiang, Shiang-Huei
    Wu, Jay
    HEALTH PHYSICS, 2017, 112 (05): : 470 - 477
  • [5] TISSUE-EQUIVALENCE OF H2 GAS FOR MICRODOSIMETRY IN NEUTRON FIELDS: A GEANT4 MONTE CARLO STUDY
    Chattaraj, Arghya
    Selvam, T. Palani
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (3-4) : 202 - 211
  • [6] Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110
    Galeano, D. C.
    Santos, W. S.
    Alves, M. C.
    Souza, D. N.
    Carvalho, A. B., Jr.
    RADIATION PHYSICS AND CHEMISTRY, 2016, 121 : 50 - 60
  • [7] DOSE3D: EGS4 Monte Carlo code-based software for internal radionuclide dosimetry
    Clairand, I
    Ricard, M
    Gouriou, J
    Di Paola, M
    Aubert, B
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (09) : 1517 - 1523